Sania Vidas Pauk

Dr. Sania Vidas Pauk

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Acta Clinica Croatica
Verified
Journal Article
Open access
PDF file
SPSania Vidas Pauk
Sania Vidas Pauk
IPIgor Petriček
Igor Petriček
TJTomislav Jukić
Tomislav Jukić
SPSmiljka Popović-Suić
Smiljka Popović-Suić
MTMartina Tomić
Martina Tomić
SMSanja Masnec
Sanja Masnec
The aim was to determine feasibility and reliability of noninvasive tear break-up time (NIBUT) assessment using handheld lipid layer examination instrument, and to compare it with standard tear break-up time (TBUT) test. Fifty patients...

28 September 2022 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
SJSonja Jandrokovic
Sonja Jandrokovic
SPSania Vidas Pauk
Sania Vidas Pauk
DGDina Lešin Gaćina
Dina Lešin Gaćina
IŠIvan Škegro
Ivan Škegro
Martina TomićMartina Tomić
Martina Tomić
MKMiro Kalauz
Miro Kalauz
Purpose: To evaluate the effect of switching from preserved prostaglandin analog-timolol fixed combinations (PG-timolol FCs) to preservative-free latanoprost-timolol FC (PF-LT) on intraocular pressure (IOP), ocular surface health, and tolerability in glaucoma and ocular hypertension (OH) patients with the concurrent ocular surface disease (OSD). Methods: This was a longitudinal, prospective, interventional, real-life study among 42 patients. Up to 3 visits were planned, at baseline, 30, and 90 days to assess efficacy on IOP decrease and local tolerance. The severity of OSD symptoms [Ocular Surface Disease Index (OSDI) questionnaire], subjective drug tolerability [visual analog scale (VAS)], conjunctival hyperemia (McMonnies scale), and tear break-up time (TBUT) were the main parameters assessed. Results: Data from 36 patients were available for statistical analysis. IOP was significantly reduced at day 30 and day 90 compared to baseline (16 vs 14 vs 14 mmHg, p < 0.001). Significant improvement was demonstrated in OSD symptoms, signs, and VAS scores from the baseline to the second and third visits. Median OSDI (27.1 vs 9.6 vs 4.2, p < 0.001), conjunctival hyperemia (2 vs 1 vs 1, p < 0.001), corneal surface staining (p < 0.001), and conjunctival staining scores (p < 0.001), and the percentage of patients with eyelid and periocular hyperemia (61.1 vs 12.5 vs 2.8%, p < 0.001), significantly decreased. TBUT (4 vs 5 vs 6 s, p < 0.001) and VAS score regarding tolerability (5 vs 2 vs 1, p < 0.001) significantly increased. Conclusion: A switch from preserved PG-timolol FCs to PF-LT improved tolerability and optimized IOP control, providing better adherence with greater chances of treatment success.

29 December 2021 in Ophthalmic Epidemiology
Verified
Journal Article
Closed access
IPIgor Petriček
Igor Petriček
SPSania Vidas Pauk
Sania Vidas Pauk
MTMartina Tomić
Martina Tomić
Tomislav BulumTomislav Bulum
Tomislav Bulum
To enquire whether patients with dry eye symptoms also report dry skin, whether their perception could be corroborated with objective measurement, and whether dry eye disease might be suspected based on patients’ complaints. This cross-sectional study included 50 subjects, 25 with and 25 without dry eye symptoms. Schein questionnaire was used to determine the severity of dry eye symptoms. Ocular signs were assessed by monitoring conjunctival hyperemia, ocular surface staining, meibomian gland expression, tear film lipid layer thickness, tear break-up time, lid parallel conjunctival folds, Schirmer test, and meibometry. Skin dryness was assessed by noting patients’ self-perception of their facial skin dryness and measured by sebumeter. Subjects without dry eye symptoms had self-reported oilier facial skin than those with dry eye symptoms (p < .001). Sebumetry scores measured on the forehead and cheek were significantly higher in subjects without dry eye symptoms than dry eye subjects (p = .003). After adjustment for age and gender in a logistic regression analysis, dry eye was independently and significantly associated with dry skin (AOR 0.69, p = .040), higher LIPCOF score of both eyes (AOR 2.28, p = .028), lower sebumetry score of the forehead (AOR 0.98, p = .041) and cheek (AOR 0.98, p = .041), and shorter TBUT score after gland expression (AOR 0.90, p = .018). This study showed that ocular dryness was subjectively and objectively positively correlated to facial skin dryness. Patients reliably described their skin condition. People with dry facial skin also had drier eyes.

1 January 2017 in Acta Clinica Croatica
Verified
Journal Article
Open access
PDF file
SPSania Vidas Pauk
Sania Vidas Pauk
SPSmiljka Popović-Suić
Smiljka Popović-Suić
KLKatia Novak Lauš
Katia Novak Lauš
SJSonja Jandroković
Sonja Jandroković
MTMartina Tomić
Martina Tomić
MKMiro Kalauz
Miro Kalauz
The aim was to compare retinal nerve fiber layer (RNFL) and ganglion cell complex (GCC) thicknesses in patients with primary open angle glaucoma (POAG), ocular hypertension (OH) and healthy subjects, and to investigate the role of GCC...

27 February 2021 in Seminars in Ophthalmology
Verified
Journal Article
Closed access
SPSania Vidas Pauk
Sania Vidas Pauk
IPIgor Petriček
Igor Petriček
MTMartina Tomić
Martina Tomić
Tomislav BulumTomislav Bulum
Tomislav Bulum
SJSonja Jandroković
Sonja Jandroković
TJTomislav Jukić
Tomislav Jukić
Purpose: To determine the feasibility of non-invasive tear break-up time (NIBUT) assessment using the Handheld tear lipid layer thickness assessment instrument and compare it with the standard tear break-up time (TBUT) test and other dry eye tests. Subjects and methods: 108 subjects were enrolled, 56 with and 52 without dry eye symptoms. Schein questionnaire was used to determine the severity of dry eye symptoms. Ocular signs were assessed by NIBUT, TBUT, lipid layer thickness (LLT), lid-parallel conjunctival folds (LIPCOF), conjunctival hyperemia, and corneal staining. Results: Median NIBUT and TBUT, and other clinical test values significantly differed among the dry eye symptoms group and control group. NIBUT yielded the most significant difference between the groups (NIBUT: 7 sec vs. 17.5 sec, p < .001, Z = 5.94; TBUT: 5 sec vs. 10 sec, p < .001, Z = 4.38; LLT: p = .007; LIPCOF: p < .001, conjunctival hyperemia: p < .047, corneal staining: p < .010). Spearman’s test showed a significant correlation between NIBUT and TBUT (p < .001), NIBUT and LLT (p = .001), NIBUT and LIPCOF (p = .019), NIBUT and conjunctival hyperemia (p = .002), and NIBUT and corneal staining (p = .012) in the dry eye symptoms group. NIBUT did not significantly differ among the three measurements in both groups of patients (p = .061, p = .096), while TBUT values did in the control group (p < .001). Short NIBUT values were the main predictors and indicators of dry eye complaints (AOR = 0.87, p < .001), superior to TBUT (AOR = 0.88, p = .008) and other tests even after adjustment for age and gender. Conclusion: NIBUT measured by Handheld instrument is a simple, accessible, practical, and, most of all, reproducible and objective method that might allow NIBUT assessment on a regular basis.

28 May 2023 in Medicina
Verified
Journal Article
Open access
PDF file
SPSania Vidas Pauk
Sania Vidas Pauk
SJSonja Jandroković
Sonja Jandroković
DGDina Lešin Gaćina
Dina Lešin Gaćina
Martina TomićMartina Tomić
Martina Tomić
Tomislav BulumTomislav Bulum
Tomislav Bulum
MKMiro Kalauz
Miro Kalauz
Purpose: To determine the 6-month effect of conventional (CXL30) and accelerated cross-linking with a UVA intensity of 9 mW/cm2 (CXL10) on corneal stability and to investigate whether there was a difference in ABCD grading system parameters regarding the two different procedures. Methods: Twenty-eight eyes of 28 patients with a documented keratoconus (KN) progression were included. Patients were selected to undergo either epi off CXL30 or CXL10. At the baseline and the follow-up visits after one (V1), three (V2), and six months (V3), the patients underwent complete ophthalmic examination and corneal tomography. Results: In the CXL30 group, all the parameters from the ABCD grading system significantly changed from baseline to V3; parameter A decreased (p = 0.048), B and C increased (p = 0.010, p < 0.001), and D decreased (p < 0.001). In the CXL10 group, there were no changes in parameters A (p = 0.247) and B (p = 0.933), though parameter C increased (p = 0.001) and D decreased (p < 0.001). After an initial decline after one month, visual acuity (VA) recovered on V2 and V3 (p < 0.001), and median maximal keratometry (Kmax) decreased in both groups (p = 0.001, p = 0.035). In the CXL30 group, there were significant changes in other parameters; average pachymetric progression index (p < 0.001), Ambrósio relational thickness maximum (ARTmax) (p = 0.008), front and back mean keratometry (p < 0.001), pachymetry apex (PA) (p < 0.001), and front elevation (p = 0.042). However, in the CXL10 group, there were significant changes only in ARTmax (p = 0.019) and PA (p < 0.001). Conclusion: Both epi-off CXL protocols showed similar short-term efficacy in improving VA and Kmax, halting the progression of KN, and both similarly changed tomographic parameters. However, the conventional protocol modified the cornea more significantly.