Conventional single photon emission computed tomography (SPECT) relies on mechanical collimation whose resolution and sensitivity are interdependent, the best performance a SPECT system can attain is only a compromise of these two equally desired properties. To simultaneously achieve high resolution and sensitivity, we propose to use sensitive detectors constructed in a m ulti-l a yer in t e r spaced mosa ic d e tector s (MATRICES) architecture to accomplish part of the collimation needed. We name this new approach self-collimation. We evaluate three self-collimating SPECT systems and report their imaging performance: 1) A simulated human brain SPECT achieves 3.88% sensitivity, it clearly resolves 0.5-mm and 1.0-mm hot-rod patterns at noise-free and realistic count-levels, respectively; 2) a simulated mouse SPECT achieves 1.25% sensitivity, it clearly resolves 50- $\mu \text{m}$ and 100- $\mu \text{m}$ hot-rod patterns at noise-free and realistic count-levels, respectively; 3) a SPECT prototype achieves 0.14% sensitivity and clearly separates 0.3-mm-diameter point sources of which the center-to-center neighbor distance is also 0.3 mm. Simulated contrast phantom studies show excellent resolution and signal-to-noise performance. The unprecedented system performance demonstrated by these 3 SPECT scanners is a clear manifestation of the superiority of the self-collimating approach over conventional mechanical collimation. It represents a potential paradigm shift in SPECT technology development.
The objective of this study was to choose the crystal surface finishing for a dual-ended readout (DER) DOI detector. Through Monte Carlo simulations and experimental studies, we evaluated 4 crystal surface finishing options as combinations of crystal surface polishing (diffuse or specular) and reflector (diffuse or specular) options on a DER detector. We also tested one linear and one logarithm DOI calculation algorithm. The figures of merit used were DOI resolution, DOI positioning error, and energy resolution. Both the simulation and experimental results show that (1) choosing a diffuse type in either surface polishing or reflector would improve DOI resolution but degrade energy resolution; (2) crystal surface finishing with a diffuse polishing combined with a specular reflector appears a favorable candidate with a good balance of DOI and energy resolution; and (3) the linear and logarithm DOI calculation algorithms show overall comparable DOI error, and the linear algorithm was better for photon interactions near the ends of the crystal while the logarithm algorithm was better near the center. These results provide useful guidance in DER DOI detector design in choosing the crystal surface finishing and DOI calculation methods.
23 June 2009 in IEEE Transactions on Medical Imaging
Geometrical calibration is critical to obtaining high resolution and artifact-free reconstructed image for SPECT and CT systems. Most published calibration methods use analytical approach to determine the uniqueness condition for a specific calibration problem, and the calibration accuracy is often evaluated through empirical studies. In this work, we present a general method to assess the characteristics of both the uniqueness and the quantitative accuracy of the calibration. The method uses a singular value decomposition (SVD) based approach to analyze the Jacobian matrix from a least-square cost function for the calibration. With this method, the uniqueness of the calibration can be identified by assessing the nonsingularity of the Jacobian matrix, and the estimation accuracy of the calibration parameters can be quantified by analyzing the SVD components. A direct application of this method is that the efficacy of a calibration configuration can be quantitatively evaluated by choosing a figure-of-merit, e.g., the minimum required number of projection samplings to achieve desired calibration accuracy. The proposed method was validated with a slit-slat SPECT system through numerical simulation studies and experimental measurements with point sources and an ultra-micro hot-rod phantom. The predicted calibration accuracy from the numerical studies was confirmed by the experimental point source calibrations at ~ 0.1 mm for both the center of rotation (COR) estimation of a rotation stage and the slit aperture position (SAP) estimation of a slit-slat collimator by an optimized system calibration protocol. The reconstructed images of a hot rod phantom showed satisfactory spatial resolution with a proper calibration and showed visible resolution degradation with artificially introduced 0.3 mm COR estimation error. The proposed method can be applied to other SPECT and CT imaging systems to analyze calibration method assessment and calibration protocol optimization.
10 April 2023 in IEEE Transactions on Medical Imaging
We have recently reported a self-collimation SPECT (SC-SPECT) design concept that constructs sensitive detectors in a multi-ring interspaced mosaic architecture to simultaneously improve system spatial resolution and sensitivity. In this work, through numerical and Monte-Carlo simulation studies, we investigate this new design concept by analyzing its projection probability density functions (PPDF) and the effects of enhanced sampling, i.e. having rotational and translational object movements during imaging. We first quantitatively characterize PPDFs by their widths and edge slopes. Then we compare the PPDFs of an SC-SPECT and a series of multiple-pinhole SPECT (MPH-SPECT) systems and assess the impact of PPDFs — combined with enhanced sampling — on image contrast recovery coefficient and variance through phantom studies. We show the PPDFs of SC- SPECT have steeper edges and a wider range of width, and these attributes enable SC-SPECT to achieve better performance
24 August 2021 in IEEE Transactions on Radiation and Plasma Medical Sciences
The Bragg peak phenomenon empowers proton therapy in targeted dose delivery in principle and also critically demands high accuracy of proton beam’s dispatch track in practice. To ensure the accuracy, prompt gamma imaging (PGI) systems were studied for monitoring the delivery of proton beams in real time. In this work, a dual-head PGI system was proposed and optimized with multislit collimators and BGO scintillators. The dual-head system was then assessed through a contrast recovery coefficient (CRC)-variance approach to identify a preferred setup. The performance of the PGI system was evaluated in terms of detection efficiency, spatial resolution, and positioning accuracy through a series of Monte Carlo simulations. Simulation results show that the detection efficiency of the system is 0.53% at the center of the FOV for 4.44 MeV prompt gamma, and the spatial resolution is better than 2 mm across the FOV. The positioning accuracy defined as the most distal edge position (MDEP) error is less than 2 mm along the beam incident direction at a relatively low number of detected events ( $5 \times 10^{4}$ ) in the dual-head system corresponding to a beam spot of $10 ^{8}$ incident protons. The system design is feasible for the real-time proton therapy monitoring.
25 February 2017 in Nuclear Science and Techniques