10 April 2023 in IEEE Transactions on Medical Imaging
We have recently reported a self-collimation SPECT (SC-SPECT) design concept that constructs sensitive detectors in a multi-ring interspaced mosaic architecture to simultaneously improve system spatial resolution and sensitivity. In this work, through numerical and Monte-Carlo simulation studies, we investigate this new design concept by analyzing its projection probability density functions (PPDF) and the effects of enhanced sampling, i.e. having rotational and translational object movements during imaging. We first quantitatively characterize PPDFs by their widths and edge slopes. Then we compare the PPDFs of an SC-SPECT and a series of multiple-pinhole SPECT (MPH-SPECT) systems and assess the impact of PPDFs — combined with enhanced sampling — on image contrast recovery coefficient and variance through phantom studies. We show the PPDFs of SC- SPECT have steeper edges and a wider range of width, and these attributes enable SC-SPECT to achieve better performance
9 April 2025 in IEEE Transactions on Radiation and Plasma Medical Sciences
In nuclear medicine imaging systems, intrinsic spatial resolution of the detector is one of the most important performance metrics. In this work, we aim to develop a high-resolution single photon emission computed tomography (SPECT) detector using pixelated Cedoped gadolinium aluminum gallium garnet (GAGG:Ce) scintillators and silicon photomultiplier (SiPM) arrays. Special attention is paid to improving the resolving capability of edge crystals. We propose to place optical barrier (OB) slits onto the light guide that enhances the difference in light distribution for edge crystals. We experimentally optimize OB designs for two scintillator arrays, named as Array-ESR and Array-BaSO4, which uses enhanced specular reflector (ESR) film and barium sulfate (BaSO4) as the reflectors respectively. Both arrays have 31 × 31 0.8 mm × 0.8 mm × 6 mm GAGG:Ce crystals. We introduce the flood map quality (FMQ) parameter to assess the separation of responses of neighboring crystals. The results demonstrate that for Array-ESR, an optimal light guide with two 7° OB slits and two 11° OB slits resolves 92.40 % crystals with an energy resolution of 13.19 ± 0.68%. The FMQ is 1.52 ± 0.38. For Array-BaSO4, the optimal design is a light guide with four 7° OB slits. 98.75 % crystals are resolvable with an energy resolution of 15.33 ± 0.96 % and FMQ parameter of 1.81 ± 0.45. Overall, Array-BaSO4 is more suitable for building SPECT detector for its good crystal resolving performance and fabrication convenience. This study proposes a practical sub-millimeter pixelated SPECT detector design with no detection dead space and compact electronics. It is promising for being used to build largescale detectors for high resolution SPECT systems.
3 November 2023 in Medical Physics
2 February 2024 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
1 May 2026 in IEEE Transactions on Medical Imaging
Stemmed from our novel single-photon imaging concept of detector self-collimation-which leverages detectors themselves as collimators to overcome the inherent resolution-sensitivity trade-off in conventional SPECT-this study presents the design and evaluation of the first full-ring self-collimation SPECT (SC-SPECT) scanner for small animal imaging. The system features four concentric detector rings and two interchangeable high-aperture-ratio tungsten collimator rings optimized for high-resolution (HR) and general-purpose (GP) imaging applications. Detector rings contain 480, 720, 960, and 1,200 evenly distributed GAGG(Ce) scintillators, each measuring 0.84 mm (tangential) × 6 mm (radial) × 20 mm (axial) and separated by 0.84-mm gaps to enable effective photon collimation. Inner detector rings and the collimator ring collectively provide collimation for photons reaching subsequent outer rings. Dual-end SiPM readouts facilitate axial depth-of-interaction measurements. Phantom and mouse studies are performed to assess the system's resolution, sensitivity, and field-of-view volume, and SC-SPECT demonstrates generally superior performance compared with state-of-the-art small-animal SPECT systems. Mouse bone images using 99mTc-MDP show CT-like resolution, clearly delineating detailed tracer uptake distributions within small structures such as mouse paws and skulls, indicating a significant technological advancement in small-animal SPECT imaging.