Due to improved laser scanning technology, laser scanner based deformation analyses are presently widespread. These deformation analyses are no longer based on individual points representing the deformation of an object at selected positions. Instead, they are based on a large number of scan points sampling the whole object. This fact either leads to challenges regarding metrological aspects as well as regarding modeling aspects:
As laser scanning technology has improved a lot in recent years, terrestrial laser scanners (TLS) have become popular devices for surveying tasks with high accuracy demands, such as deformation analyses. For this reason, finding a stochastic model for TLS measurements is very important in order to get statistically reliable results. The measurement accuracy of laser scanners—especially of their rangefinders—is strongly dependent on the scanning conditions, such as the scan configuration, the object surface geometry and the object reflectivity. This study demonstrates a way to determine the intensity-dependent range precision of 3D points for terrestrial laser scanners that measure in 3D mode by using range residuals in laser beam direction of a best plane fit. This method does not require special targets or surfaces aligned perpendicular to the scanner, which allows a much quicker and easier determination of the stochastic properties of the rangefinder. Furthermore, the different intensity types—raw and scaled—intensities are investigated since some manufacturers only provide scaled intensities. It is demonstrated that the intensity function can be derived from raw intensity values as written in literature, and likewise—in a restricted measurement volume—from scaled intensity values if the raw intensities are not available.
During the registration and georeferencing of terrestrial laser scans, it is common to use targets to mark discrete points. To improve the accuracy of the registration, the uncertainties of the target center estimation (TCE) have to be minimized. The present study examines different factors influencing the precision of the TCE. Here, the focus is on the algorithm and the target design. It is determined that, in general, the uncertainties of the TCE are much smaller than those indicated by the manufacturers. By comparing different algorithms for the first time, it was possible to clearly determine that an algorithm using image correlations yields the smallest standard deviations for the TCE. A comparison of different target designs could not identify an ideal commercially available target. For this reason, a new target, the BOTA8 (BOnn TArget with 8-fold pattern) was developed, which leads to smaller standard deviations than the previous targets. By choosing the best algorithm and improving the target design, standard deviations of mm in distance direction and arcsec in angular direction for a scan distance up to 100 m were achieved with the laser scanner Leica ScanStation P20. The uncertainties could be reduced by several millimetres and angular seconds compared to the manufacturer’s targets and software.
In terms of high precision requested deformation analyses, evaluating laser scan data requires the exact knowledge of the functional and stochastic model. If this is not given, a parameter estimation leads to insufficient results. Simulating a laser scanning scene provides the knowledge of the exact functional model of the surface. Thus, it is possible to investigate the impact of neglecting spatial correlations in the stochastic model. Here, this impact is quantified through statistical analysis. The correlation function, the number of scanning points and the ratio of colored noise in the measurements determine the covariances in the simulated observations. It is shown that even for short correlation lengths of less than 10 cm and a low ratio of colored noise the global test as well as the parameter test are rejected. This indicates a bias and inconsistency in the parameter estimation. These results are transferable to similar tasks of laser scanner based surface approximation.
Terrestrial laser scanner measurements suffer from systematic errors due to internal misalignments. The magnitude of the resulting errors in the point cloud in many cases exceeds the magnitude of random errors. Hence, the task of calibrating a laser scanner is important for applications with high accuracy demands. This paper primarily addresses the case of panoramic terrestrial laser scanners. Herein, it is proven that most of the calibration parameters can be estimated from a single scanner station without a need for any reference information. This hypothesis is confirmed through an empirical experiment, which was conducted in a large machine hall using a Leica Scan Station P20 panoramic laser scanner. The calibration approach is based on the widely used target-based self-calibration approach, with small modifications. A new angular parameterization is used in order to implicitly introduce measurements in two faces of the instrument and for the implementation of calibration parameters describing genuine mechanical misalignments. Additionally, a computationally preferable calibration algorithm based on the two-face measurements is introduced. In the end, the calibration results are discussed, highlighting all necessary prerequisites for the scanner calibration from a single scanner station.