Benoit Gilbert

Prof. Benoit Gilbert

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2017 in Journal of Cleaner Production
Verified
Journal Article
Closed access
HLHangyong Ray Lu
Hangyong Ray Lu
AHAli El Hanandeh
Ali El Hanandeh
BGBenoit Gilbert
Benoit Gilbert

1 February 2019 in Engineering Structures
Verified
Journal Article
Closed access
FMFuhao Ma
Fuhao Ma
BGBenoit Gilbert
Benoit Gilbert
HGHong Guan
Hong Guan
HXHuizhong Xue
Huizhong Xue
XLXinzheng Lu
Xinzheng Lu
YLYi Li
Yi Li

1 March 2020 in Construction and Building Materials
Verified
Journal Article
Closed access
Hassan KarampourHassan Karampour
Hassan Karampour
MBMélanie Bourges
Mélanie Bourges
BGBenoit Gilbert
Benoit Gilbert
ABAndrew Bismire
Andrew Bismire
HBHenri Bailleres
Henri Bailleres
HGHong Guan
Hong Guan

1 July 2018 in Journal of Structural Engineering
Verified
Journal Article
Closed access
HXHuizhong Xue
Huizhong Xue
BGBenoit Gilbert
Benoit Gilbert
HGHong Guan
Hong Guan
XLXinzheng Lu
Xinzheng Lu
YLYi Li
Yi Li
Ying TianYing Tian
Ying Tian
Reinforced concrete (RC) flat-plate structures are vulnerable to punching shear failure at their slab-column connections, potentially leading to a catastrophic progressive collapse. In practice, the slab-column connection above an interior column, removed due to abnormal loads, may be subjected to a concentrated downward force because of the absence of the supporting column and further being pushed as a result of different live load intensities on individual stories. This force is different from the full design load that the column withstands in normal situations and, combined with the gravity load acting on the slab, may cause punching shear failure at the interior slab-column connection. This will further trigger failure propagation to the surrounding slab-column connections. This paper presents the experimental tests performed on two identical large-scale 2×2 -bay RC flat-plate specimens under an interior column removal scenario. A 5-kPa uniformly distributed load was applied first to the slab followed by an incremental concentrated force imposed on the slab-column connection above the removed interior column. The complete collapse-resistant behavior and load redistribution pattern of the specimens were investigated and are reported herein. Results show that more than 90% of the applied concentrated force is solely distributed to the four nearest adjacent columns. Three load-carrying mechanism phases, in the form of flexural, tensile membrane, and a combination of one-way catenary and dowel actions can be distinguished in resisting the applied concentrated load.

1 June 2010 in Journal of Constructional Steel Research
Verified
Journal Article
Closed access
BGBenoit Gilbert
Benoit Gilbert
KRKim J.R. Rasmussen
Kim J.R. Rasmussen

1 November 2012 in Thin-Walled Structures
Verified
Journal Article
Closed access
BGBenoit Gilbert
Benoit Gilbert
TSTimothee J.-M. Savoyat
Timothee J.-M. Savoyat
LTLip H. Teh
Lip H. Teh