Tissue-engineered scaffolds are an effective method for the treatment of bone defects, and their structure and function are essential for bone regeneration. Digital light processing (DLP) printing technology has been widely used in bone tissue engineering (BTE) due to its high printing resolution and gentle printing process. As commonly used bioinks, synthetic polymers such as polyethylene glycol diacrylate (PEGDA) and Pluronic F127 diacrylate (F127DA) have satisfactory printability and mechanical properties but usually lack sufficient adhesion to cells and tissues. Here, a compound BTE scaffold based on PEGDA, F127DA, and gelatin methacrylate (GelMA) was successfully prepared using DLP printing technology. The scaffold not only facilitated the adhesion and proliferation of cells, but also effectively promoted the osteogenic differentiation of mesenchymal stem cells in an osteoinductive environment. Moreover, the bone tissue volume/total tissue volume (BV/TV) of the GelMA/PEGDA/F127DA (GPF) scaffold in vivo was 49.75 ± 8.50%, higher than the value of 37.10 ± 7.27% for the PEGDA/F127DA (PF) scaffold and 20.43 ± 2.08% for the blank group. Therefore, the GPF scaffold prepared using DLP printing technology provides a new approach to the treatment of bone defects.
Microglia, as the resident immune cells and first responder to neurological insults, play an extremely important role in the pathophysiological process of spinal cord injury. On the one hand, microglia respond rapidly and gather around the lesion in the early stage of injury to exert a protective role, but with the continuous stimulation of the injury, the excessive activated microglia secrete a large number of harmful substances, aggravate the injury of spinal cord tissue, and affect functional recovery. The effects of microglia depletion on the repair of spinal cord injury remain unclear, and there is no uniformly accepted paradigm for the removal methods and timing of microglia depletion, but different microglia depletion strategies greatly affect the outcomes after spinal cord injury. Therefore, this review summarizes the physiological and pathological roles of microglia, especially the effects of microglia depletion on spinal cord injury—sustained microglial depletion would aggravate injury and impair functional recovery, while the short-term depletion of microglial population in diseased conditions seems to improve tissue repair and promote functional improvement after spinal cord injury. Furthermore, we discuss the advantages and disadvantages of major strategies and timing of microglia depletion to provide potential strategy for the treatment of spinal cord injury.
The treatment of critical-size bone defects remains a complicated clinical challenge. Recently, bone tissue engineering has emerged as a potential therapeutic approach for defect repair. This study examined the biocompatibility and repair efficacy of hydroxyapatite-mineralized bionic polylactic acid (PLA) scaffolds, which were prepared through a combination of 3D printing technology, plasma modification, collagen coating, and hydroxyapatite mineralization coating techniques. Physicochemical analysis, mechanical testing, and in vitro and animal experiments were conducted to elucidate the impact of structural design and microenvironment on osteogenesis. Results indicated that the PLA scaffold exhibited a porosity of 84.1% and a pore size of 350 μm, and its macrostructure was maintained following functionalization modification. The functionalized scaffold demonstrated favorable hydrophilicity and biocompatibility and promoted cell adhesion, proliferation, and the expression of osteogenic genes such as ALP, OPN, Col-1, OCN, and RUNX2. Moreover, the scaffold was able to effectively repair critical-size bone defects in the rabbit radius, suggesting a novel strategy for the treatment of critical-size bone defects.
The treatment of complex acetabular fractures remains a complicated clinical challenge. Our self-designed novel anatomical locking guide plate (NALGP) has previously shown promising potential in T-shaped acetabular fractures (TAF), but a direct comparison with conventional fixations is yet to be made. The TAF model was established based on a volunteer’s computer tomography data and then fixed with double column locking plates (DLP), a posterior column locking plate with anterior column screws (LPACS), and our NALGP. Forces of 200 N, 400 N, and 600 N were then loaded on the model vertically downward, respectively. The stress distribution and peaks and maximum displacements at three sites were assessed. We found that the stress area of all three plates was mainly concentrated around the fracture line, while only the matching screws of the NALGP showed no obvious stress concentration points. In addition, the NALGP and DLP showed significantly less fracture fragment displacement than the LPACS at the three main fracture sites. The NALGP was found to have less displacement than DLP at the posterior column and ischiopubic branch sites, especially under the higher loading forces of 400 N and 600 N. The fixation stability of the NALGP for TAF was similar to that of DLP but better than that of LPACS. Moreover, the NALGP and its matching screws have a more reasonable stress distribution under different loads of force and the same strength as the LPACS.
Background: To study the segmental uncoverage ratio (UCR) of a 44-mm cup model placed in a true acetabulum of Crowe type-IV developmental dysplasia of the hip via 3-Dimensional (3D) implantation simulation.Methods: Qualified CT imaging data of 26 patients (involving 30 hips) with Crowe type-IV DDH were imported into Mimics software for reconstruction. Then a 44-mm eggshell cup model was placed in a true acetabulum. First, total uncoverage ratio (TUCR) was measured. Then the virtual cup was divided into 4 segments according to the quadrant setting of the true acetabulum, i.e., anterior-superior (A-S) segment, anterior-inferior (A-I) segment, posterior-superior (P-S) segment and posterior-inferior (P-I) segment. The UCRs of the aforementioned segments were measured, i.e., anterior-superior uncoverage ratio (A-SUCR), anterior-inferior uncoverage ratio (A-IUCR), posterior-superior uncoverage ratio (P-SUCR) and posterior-inferior uncoverage ratio (P-IUCR). The acetabular height and anterior-posterior diameter on the 3-D model were also calculated. Statistic analyses were performed by using SPSS software package.Results: TUCR was 0.2958 ± 0.1003 (95% [CI], 0.1020 to 0.5400) in this cohort of Crowe Type-IV hips. P-SUCR had the greatest value among all the segmental UCRs (0.1012 ± 0.0435, 95% confidence interval [CI],0.0152 to 0.1914) and the most significant positive correlation with TUCR (Pearson correlation = 0.889,p < 0.01. Linear regression R2 = 0.791). Similarly, P-IUCR and A-SUCR showed a significant positive correlation with TUCR. However, A-IUCR exhibited no correlation with either total or other segmental UCRs. P-SUCR was found to bear significant positive correlation with P-IUCR (pearson correlation = 0.644,p < 0.01. Linear regression R2 = 0.415). Acetabular height and A-P diameter were not correlated with TUCR.Conclusion: Implantation of a 44-mm cup into Crowe type IV acetabulum is feasible and could achieve acceptable host bone coverage in most of the cases. P-SUCR contributed most to TUCR. TUCR had no linear relationship with the size of the host acetabulum, suggesting that the pre-operative plan should be individualized.
Background: 18F-NaF and 99mTc-MDP are widely used bone imaging tracers, but their comparative uptake in bone versus cartilage is unclear. This study aimed to directly compare these patterns in rats to guide musculoskeletal molecular imaging. Methods: Male Sprague-Dawley rats underwent in vivo and ex vivo radiotracer studies. Tracer uptake (%ID/g) was quantified in bone and cartilage at 30, 60, or 120 min post-injection (18F-NaF or 99mTc-MDP), and across different ages. Additional rats received subcutaneous implants of viable or devitalized bone and cartilage; uptake was assessed using PET/CT, autoradiography, and histology. Results: 18F-NaF showed faster blood/background clearance and higher target-to-background ratios compared to 99mTc-MDP, especially in weight-bearing joint cartilage. 18F-NaF uptake in cancellous bone significantly exceeded that of 99mTc-MDP, whereas 99mTc-MDP showed higher uptake in knee cartilage. Age-related analysis showed maximal knee cartilage accumulation in aged rats. Histological and cell inactivation studies confirmed that 18F-NaF uptake reflects both cellular activity and degree of calcification. Conclusions:18F-NaF demonstrates distinctive, quantifiable uptake in cartilage, dependent on both cellular activity and calcification, and exhibits favorable imaging characteristics versus 99mTc-MDP for cartilage metabolism. These findings support 18F-NaF as a promising tool for early diagnosis and therapeutic monitoring of bone and joint disorders, and provide pathophysiological insight into the dynamics of the bone–cartilage interface.