The aim of this study was to determine the dosimetric parameters of radiation to which orthopedic in-patients are exposed, using data drawn from the hospital's picture archiving and communication system. Data for 310 patients, relating to seven different anatomical districts, were examined. Femoral operations were divided into three types. The 75th percentile dose at the interventional reference point (IRP) exceeded 2 mGy only for femoral interventions (4.6-6.2 mGy) with 75th percentile kerma-area product (KAP) values ranging from 84.8 to 109.1 mu Gy m(2). The 75th percentile fluoroscopy time was longer than 1 min only for the humeral operations and the three types of femoral intervention. In general, the radiation exposure times and doses recorded in our institute were lower than those reported in the literature. The correlation between KAP and kerma at the IRP was very strong for all districts (R > 0.80). The correlation between KAP and fluoroscopy times was very strong for seven cases (R > 0.80), and strong for two (0.60 < R < 0.79).
The data analysed came from 545 patients and were related to five types of procedures performed in the urology operating room: percutaneous nephrolithotomy (PCNL), retrograde intrarenal surgery (RIRS), ureteropyeloscopy (UPS), ureteral catheterisation and nephrostomy. Local reference levels (75th percentiles) were determined for the various procedures. The peak entrance skin dose for a patient 20 cm thick was highest for PCNL, being 82 mGy, followed by 43 mGy for nephrostomy, 23 mGy for RIRS, 23 mGy for UPS and 17 mGy for stenting. Even taking into account the maximum values measured (296 mGy for UPS), the doses reached at the skin were not such as to cause deterministic effects. However, the threshold dose for male temporary sterility could be reached (150 mGy).
Introduction: Radiation exposure is a frequent drawback of spinal surgery, even if X-ray guidance plays a pivotal role in improving the accuracy and safety of spinal procedures. Consequently, radiation protection is essential to reduce potential negative biological effects. The aim of this study was to evaluate patients’ radiation exposure, the radiation dose emission during fluoroscopy-guided ozone chemonucleolysis (OCN), and the potential role of patient characteristics. Methods: The radiation dose emission reports were retrospectively evaluated in patients who underwent single-level OCN for lumbar disc herniation. A generalized linear model (GLM) with a gamma distribution and log link function was used to assess the association between radiation emission and patients’ characteristics such as age, sex, BMI, level of disc herniation, disc height, and site of disc herniation. Results: Two hundred and forty OCN cases were analyzed. A safe and low level of radiation exposure was registered during OCN. The median fluoroscopy time for OCN was 26.3 (19.4–35.9) seconds, the median radiation emission dose was 19.3 (13.2–27.3) mGy, and he median kerma area product (KAP) was 0.46 (0.33–0.68) mGy ⋅ m2. The resulting KAP values were highly dependent on patient variables. In particular, sex, obesity, and residual disc height < 50% significantly increased the measured KAP, while levels of disc herniations other than L5-S1 reduced the KAP values. Conclusions: The radiation exposure during OCN is low and quite similar to a simple discography. However, patient characteristics are significantly related to radiation exposure and should be carefully evaluated before planning OCN.