Novel dry electrodes are increasingly evolving for monitoring electrocardiograms compared to the widely used Ag/AgCl (wet) electrodes as there is no skin preparation or wet gel needed. Many fabricated dry electrodes are however opaque, and the problem of skin irritation and rashes continue to pose a concern. In this paper, an optically unobtrusive dry electrode based on the iono-electric properties of zeolite is developed and proposed for continuous electrocardiogram (ECG) monitoring. An easily moldable composite of the sodium form of nano-porous zeolite and polydimethylsiloxane (PDMS) is reported for the first time. The electrical and bio-electrical characterizations are evaluated for 24 pairs of electrodes which were fabricated with two filler materials (Zeolite 4A and 13X), two filler concentrations (4 wt% and 12 wt%), three diameters (30 mm, 20 mm, and 10 mm), and differing thicknesses. High input impedance and high conductivity of the electrodes have proven the suitability for biosignal acquisition. ECG signals are acquired using each pair of electrodes. Results related to impedance, conductivity, and SNR measurements over a frequency range up to 10 kHz are presented. Among the 24 pairs, the results indicate that signal-to-noise ratio (SNR) for Zeolite 13X/PDMS- based filler with a concentration of 4 wt% and diameter of 30 mm has the highest SNR of 42.9 dB and conductivity of 0.58 μS/mm. These electrodes are optically unobtrusive and easy to fabricate. Hence this process yields promising results for the next generation of wearable cardiovascular heart monitoring systems.
The survival rate for sudden cardiac arrest (SCA) is low, and patients with long-term risks of SCA are not adequately alerted. Understanding SCA’s characteristics will be key to developing preventive strategies. Many lives could be saved if SCA’s early onset could be detected or predicted. Monitoring heart signals continuously is essential for diagnosing sporadic cardiac dysfunction. An electrocardiogram (ECG) can be used to continuously monitor heart function without having to go to the hospital. A zeolite-based dry electrode can provide safe on-skin ECG acquisition while the subject is out-of-hospital and facilitate long-term monitoring. To the ECG signal, a low-power 1 μW read-out circuit was designed and implemented in our prior work. However, having long-term ECG monitoring outside the hospital, i.e., high battery life, and low power consumption while transmission and reception of ECG signal are crucial. This paper proposes a prototype with a 10-bit resolution ADC and nRF24L01 transceivers placed 5 m apart. The system uses the 2.4 GHz worldwide ISM frequency band with GFSK modulation to wirelessly transmit digitized ECG bits at 250 kbps data rate to a physician’s computer (or similar) for continuous monitoring of ECG signals; the power consumption is only 11.2 mW and 4.62 mW during transmission and reception, respectively, with a low bit error rate of ≤0.1%. Additionally, a subject-wise cross-validated, three-fold, optimized convolutional neural network (CNN) model using the Physionet-SCA dataset was implemented on NVIDIA Jetson to identify the irregular heartbeats yielding an accuracy of 89% with a run time of 5.31 s. Normal beat classification has an F1 score of 0.94 and a ROC score of 0.886. Thus, this paper integrates the ECG acquisition and processing unit with low-power wireless transmission and CNN model to detect irregular heartbeats.
29 July 2021 in Journal of Signal Processing Systems