The Inverse Method is a widely used technique for the determination of adsorption isotherms in liquid chromatography. In this method, isotherm is determined from the overloaded peak profile of the component by the iterative solution of the mass balance equation of liquid chromatography. Successful use of this method requires a prior assumption of equation of isotherm (Langmuir, BET etc.). In this work, we have developed an inverse method that gives results of similar accuracy to the frontal analysis without assuming the equation of the isotherm. The oversaturated peaks were calculated using a spline fitted to data points instead of the derivative of the isotherm. The distribution of the isotherm points were optimized for minimizing the difference between the measured and calculated overloaded peaks. The accuracy of the developed method was verified with synthetic benchmark peaks and by the determination of isotherm of buthyl-benzoate under real conditions. The results confirmed that the accuracy of the developed method is similar to that of Frontal Analysis.
Highly efficient columns are necessary for the modern analytical applications of liquid chromatography. In this work, the separation efficiency of ion-exchange capacity gradient stationary phases combined with eluent concentration gradient was studied by a theoretical approach. In the course of our work three different scenarios of capacity gradients were used with different shapes (linear, convex and concave). The resolutions of different gradient columns were calculated for each scenario. As a reference, a uniform column was considered, which had the same analysis time as the non-uniform column. In the case of separation of ions with same charges, the gradient column offered only a marginal advantage compared to the uniform column due to the bandwidth compression caused by the capacity gradient. In the case of ions with different charges, however, the advantage of the gradient column was more significant. This was mainly due to the increased retention time difference of solutes. Ion-exchange capacity gradient columns may be a new way to separate ions more efficiently.
In chromatography, pressure can affect the retention factors of compounds significantly. In liquid chromatography, this effect is primarily related to the change in the molecular volume of solute during adsorption that is remarkably high for large biomolecules such as peptides and proteins. As a result, the migration velocities of chromatographic bands vary spatially through the column affecting the degree of band broadening. In this work, based on theoretical considerations, chromatographic efficiencies are studied under pressure-induced gradient conditions. The retention factor and migration velocity of different components are examined, and it is shown that components with the same retention time can have different migration patterns. The width of the initial band after injection is affected by the pressure gradient, providing significantly thinner initial bands for compounds with higher pressure sensitivity. In addition to classical band broadening phenomena, the influence of pressure gradients on band broadening is remarkable. The positive velocity gradient leads to extra band broadening. Our results clearly demonstrate that the zones are significantly wider at the end of the column if the change of molar volume of solute during adsorption is large. If the pressure drop is increasing, this effect becomes more significant. In the same time, the high release velocity of the bands somewhat counteracts the extra band broadening effect, however, it can not offset it perfectly. As a result, the separation efficiency of large biomolecules is decreased significantly due to the chromatographic pressure gradient. Under UHPLC conditions, the extent of apparent efficiency loss can reach up to 50% compared to the intrinsic efficiency of the column.
The ion-exchange and complex forming equilibria were quantitatively described and demonstrated in order to understand major factors in the control of selectivity in the analytical separation of carboxylic acids and inorganic anions in cryptand based ion chromatography. A complex retention model has been developed for the separation on a non-conventional IC column. Changes in retention are treated both theoretically and experimentally. Retention mechanism is employed on a macrocycle-based (cryptand n-decyl-[2.2.2]) ion-exchange chromatographic phase to improve the selectivity for a mixture of model analytes. We introduced an alternative internal gradient method by mixed eluent (i.e. eluents formed by combination of two alkali hydroxide with different molar ratio). The effect of binary mixed eluent (Li/Na, Li/K) on the retention behavior and peak shape of carboxylic acids are also discussed in view of the proposed theory. It was shown that the effects of binary aqueous mobile phases, held isocratically behave very similar to the step gradient mode. The "internal gradient" separation system has advantages over traditional step gradient mode. Twenty-six anions of widely varying chemical character (mono-, di-, tri-valent inorganic anions, mono-, di-, tri-valent aliphatic carboxylic acids, aromatic- and haloacetic carboxylic acids) were investigated on the cryptand-based (D222) stationary phase using different methods by LiOH, NaOH and KOH eluent. The predicted vs measured retention data are in rather good agreement. High degree of linearity was obtained for inorganic anions, multivalent carboxylic acids, and for aromatic and haloacetic acids R2 = 0.992, 0.969, and 0.980, respectively.