Triton X-100 is one of the most widely-applied man-made non-ionic surfactants. This detergent can hardly be degraded by biological treatment. Hence, a more efficient degradation method is indispensable for the total mineralization of this pollutant. Application of heterogeneous photocatalysis based on a TiO2 suspension is a possible solution. Its efficiency may be improved by the addition of various reagents. We have thoroughly examined the photocatalytic degradation of Triton X-100 under various circumstances. For comparison, the efficiencies of ozonation and treatment with peroxydisulfate were also determined under the same conditions. Besides, the combination of these advanced oxidation procedures (AOPs) were also studied. The mineralization of this surfactant was monitored by following the TOC and pH values, as well as the absorption and emission spectra of the reaction mixture. An ultra-high-performance liquid chromatography (UHPLC) method was developed and optimized for monitoring the degradation of Triton X-100. Intermediates were also detected by GC-MS analysis and followed during the photocatalysis, contributing to the elucidation of the degradation mechanism. This non-ionic surfactant could be efficiently degraded by TiO2-mediated heterogeneous photocatalysis. However, surprisingly, its combination with the AOPs applied in this study did not enhance the rate of the mineralization. Moreover, the presence of persulfate hindered the photocatalytic degradation.
High performance anion chromatography (HPIC) method to separate ionic Gd chelates, , , and free matrix anions was developed. At alkaline pHs, polydentate complexing agents such as ethylene-diamine-tetraacetate, diethylene-triamine pentaacetate and trans-1,2-diamine-cyclohexane-tetraacetate tend to form stable Gd chelate anions and can be separated by anion exchange. Separations were studied in the simple isocratic chromatographic run over the wide range of pH and concentration of carbonate eluent using suppressed conductivity detection. The ion exchange and complex forming equilibria were quantitatively described and demonstrated in order to understand major factors in the control of selectivity of Gd chelates. Parameters of optimized resolution between concurrent ions were presented on a 3D resolution surface. The applicability of the developed method is represented by the simultaneous analysis of Gd chelates and organic/inorganic anions. Inductively coupled plasma atomic emission spectroscopy (ICP-AES) analysis was used for confirmation of HPIC results for Gd. Collection protocols for the heart-cutting procedure of chromatograms were applied. SPE procedures were also developed not only to extract traces of free gadolinium ions from samples, but also to remove the high level of interfering anions of the complex matrices. The limit of detection, the recoverability and the linearity of the method were also presented.
The ion-exchange and complex forming equilibria were quantitatively described and demonstrated in order to understand major factors in the control of selectivity in the analytical separation of carboxylic acids and inorganic anions in cryptand based ion chromatography. A complex retention model has been developed for the separation on a non-conventional IC column. Changes in retention are treated both theoretically and experimentally. Retention mechanism is employed on a macrocycle-based (cryptand n-decyl-[2.2.2]) ion-exchange chromatographic phase to improve the selectivity for a mixture of model analytes. We introduced an alternative internal gradient method by mixed eluent (i.e. eluents formed by combination of two alkali hydroxide with different molar ratio). The effect of binary mixed eluent (Li/Na, Li/K) on the retention behavior and peak shape of carboxylic acids are also discussed in view of the proposed theory. It was shown that the effects of binary aqueous mobile phases, held isocratically behave very similar to the step gradient mode. The "internal gradient" separation system has advantages over traditional step gradient mode. Twenty-six anions of widely varying chemical character (mono-, di-, tri-valent inorganic anions, mono-, di-, tri-valent aliphatic carboxylic acids, aromatic- and haloacetic carboxylic acids) were investigated on the cryptand-based (D222) stationary phase using different methods by LiOH, NaOH and KOH eluent. The predicted vs measured retention data are in rather good agreement. High degree of linearity was obtained for inorganic anions, multivalent carboxylic acids, and for aromatic and haloacetic acids R2 = 0.992, 0.969, and 0.980, respectively.