Haoran Xu

Dr. Haoran Xu

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2024 in Instruments
Verified
Journal Article
Open access
PDF file
James RosenzweigJames Rosenzweig
James Rosenzweig
GAGerard Andonian
Gerard Andonian
RARonald Agustsson
Ronald Agustsson
PAPetr M. Anisimov
Petr M. Anisimov
AAAurora Araujo
Aurora Araujo
MYMonika Yadav
Monika Yadav
Recently, considerable work has been directed at the development of an ultracompact X-ray free-electron laser (UCXFEL) based on emerging techniques in high-field cryogenic acceleration, with attendant dramatic improvements in electron beam brightness and state-of-the-art concepts in beam dynamics, magnetic undulators, and X-ray optics. A full conceptual design of a 1 nm (1.24 keV) UCXFEL with a length and cost over an order of magnitude below current X-ray free-electron lasers (XFELs) has resulted from this effort. This instrument has been developed with an emphasis on permitting exploratory scientific research in a wide variety of fields in a university setting. Concurrently, compact FELs are being vigorously developed for use as instruments to enable next-generation chip manufacturing through use as a high-flux, few nm lithography source. This new role suggests consideration of XFELs to urgently address emerging demands in the semiconductor device sector, as identified by recent national need studies, for new radiation sources aimed at chip manufacturing. Indeed, it has been shown that one may use coherent X-rays to perform 10–20 nm class resolution surveys of macroscopic, cm scale structures such as chips, using ptychographic laminography techniques. As the XFEL is a very promising candidate for realizing such methods, we present here an analysis of the issues and likely solutions associated with extending the UCXFEL to harder X-rays (above 7 keV), much higher fluxes, and increased levels of coherence, as well as methods of applying such a source for ptychographic laminography to microelectronic device measurements. We discuss the development path to move the concept to rapid realization of a transformative XFEL-based application, outlining both FEL and metrology system challenges.

6 February 2019 in Physical Review Accelerators and Beams
Verified
Journal Article
Open access
PDF file
HXHaoran Xu
Haoran Xu
MSM. A. Shapiro
M. A. Shapiro
RTR. J. Temkin
R. J. Temkin
We report the measurement of the internal dark current in a 17 GHz, high gradient accelerator cavity and its comparison with theory. The cavities were fabricated from copper and had a sidewall that was either uncoated or coated with diamondlike carbon or TiN. The dark current was monitored by a downstream detector and by detectors behind two small slits made in the cavity sidewall. With an increasing gradient, the downstream current increased monotonically, as expected for field emission. The variation of the internal, side dark current was not monotonic but showed the onset of peaks at gradients near 45 and 65  MV/m. These were identified as the N=2 and N=1 single point multipactor resonances. The total internal dark current was estimated at ∼15–30  A. The magnitude of the internal dark current and its dependence on the gradient were in good agreement with simulations using the cst code as well as an in-house code. Processing to a higher gradient, ∼90  MV/m, eliminated the N=2 mode, but the N=1 mode persisted. The coated sidewall cavities showed the same multipactor resonances as the uncoated structure. However, at the highest gradient achieved in testing, the coated structures showed a modest reduction in the internal dark current.

10 February 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HXHaoran Xu
Haoran Xu
PAPetr M. Anisimov
Petr M. Anisimov
Bruce CarlstenBruce Carlsten
Bruce Carlsten
LDLeanne D. Duffy
Leanne D. Duffy
QMQuinn R. Marksteiner
Quinn R. Marksteiner
RRRiver Robles
River Robles
We report the start-to-end modeling of our accelerator lattice design employing a laser-assisted bunch compression (LABC) scheme in an X-ray free electron laser (XFEL), using the proposed Matter-Radiation Interactions in Extremes (MaRIE) XFEL parameters. The accelerator lattice utilized a two-stage bunch compression scheme, with the first bunch compressor performing a conventional bulk compression enhancing the beam current from 20 A to 500 A, at 750 MeV. The second bunch compression was achieved by modulating the beam immediately downstream of the first bunch compressor by a laser with 1-μm wavelength in a laser modulator, accelerating the beam to the final energy of 12 GeV, and compressing the individual 1-μm periods of the modulated beam into a sequence of microbunches with 3-kA current spikes by the second bunch compressor. The LABC architecture presented had been developed based on the scheme of enhanced self-amplified spontaneous emission (ESASE), but operated in a disparate regime of parameters. Enabled by the novel technology of the cryogenic normal conducting radiofrequency photoinjector, we investigated an electron beam with ultra-low emittance at the starting point of the lattice design. Our work aimed at mitigating the well-known beam instabilities to preserve the beam emittance and suppress the energy spread growth.

2 March 2021 in IEEE Transactions on Electron Devices
Verified
Journal Article
Closed access
HXHaoran Xu
Haoran Xu
QMQuinn R. Marksteiner
Quinn R. Marksteiner
Bruce CarlstenBruce Carlsten
Bruce Carlsten
In this article, we report theoretical and design studies on the application of an electrostatic potential depression (EPD) on two types of traditional microwave sources, the klystron and the inductive output tube (IOT), both operating in the UHF band. The EPD is implemented by a section of the metallic beam pipe on which a direct current (dc) negative high voltage is applied. Inside the EPD section, the modulated electron beam develops into bunches over a very short longitudinal distance, indicating a possible design approach for a compact device. With the application of an EPD, the peak value of the first harmonic current in a microwave tube can be further increased compared to that in a conventional design, suggesting higher circuit efficiency. As the electron beam leaves the EPD section, the reacceleration of the beam provides a longitudinal cooling effect. With the addition of an EPD, circuit power extraction efficiency above 80% is achieved in both the modified design of the IOT and the novel conceptual circuit design of the klystron.

28 November 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
James RosenzweigJames Rosenzweig
James Rosenzweig
GAGerard Andonian
Gerard Andonian
RARonald Agustsson
Ronald Agustsson
PAPetr M. Anisimov
Petr M. Anisimov
AAAurora Araujo
Aurora Araujo
MYMonika Yadav
Monika Yadav
Recently, considerable work has been directed at development of a ultra-compact X-ray free-electron laser based on emerging techniques in high field cryogenic acceleration, with attendant dramatic improvements in electron beam brightness, and state-of-the-art concepts in beam dynamics, magnetic undulators, and X-ray optics. A full conceptual design of a 1 nm XFEL with a length and cost over an order of magnitude below current XFELs has resulted from this effort. This instrument has been developed with an emphasis on permitting exploratory scientific research in a wide variety of fields in a university setting. Concurrently, compact FELs are being urgently developed for use as an instrument to enable next generation chip manufacturing through use as a high flux, few-nm lithography source. This new role suggests consideration of XFELs to addressed urgently emerging demands in this sector, as identified by recent national need studies, for new radiation sources aimed at chip manufacturing: a coherent hard X-ray source which enables frontier metrology methods. Indeed, it has been shown that one may use coherent X-rays to perform 10 nm-class resolution surveys of macroscopic, cm-scale structures such as chips, using ptychographic laminography. As the XFEL is a very promising candidate for realizing such methods, we present here an analysis of the issues and likely solutions associated with extending the UCXFEL to harder X-rays (above 7 keV), much higher fluxes and levels of coherence, and methods of applying such a source for ptychographic laminography to micro-electronic device measurements. We discuss the development path to move the concept to rapid realization of a transformative FEL-based application, outlining FEL and metrology system challenges.

4 June 2025 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
WTWei-Hou Tan
Wei-Hou Tan
GWGlen White
Glen White
DNDimitrios Ntounis
Dimitrios Ntounis
ZLZenghai Li
Zenghai Li
DKDongsung Kim
Dongsung Kim
ENEmilio Nanni
Emilio Nanni