Buildings with mixed residential and commercial units show relevant power peak that are further increased by shifting from gas-driven systems to electric source. The proposed solution is to organize a microgrid for such type of buildings, aggregating different users with a common electric distribution system with a single connection to the grid, a local common generation and a common heating/cooling system (electric-driven). This approach upgrades a group of independent small users with rigid loads and chaotic behavior, to a large user with a flexible and controlled profile. A central building automation control system (BACS) managing all built-in technical systems and smart appliances may control the load minute by minute, shifting in time shiftable and controllable loads and merging different kinds of loads, obtaining a flatter diagram. The authors consider the suggested approach convenient to realize demand side management (DSM) for residential/commercial buildings. DSM exploits the flexibility of smart appliances and the thermal inertia of the structure, by imposing local and central set-points of heating and cooling systems according to actual global net load and generation at a given moment. In the present paper, main aspects of the proposed control system are presented and simulations for a given case study with local PV generation are provided. Results show that this approach may lead to a power peak reduction up to 20% even in the unfavorable case of combining commercial and residential units. Moreover, full self-consumption of locally generated energy from RES may be achieved.
The latest updates in the European directive on energy performance of buildings have introduced the fundamental “nearly zero-energy building (NZEB)” concept. Thus, a special focus needs to be addressed to the thermal performance of building envelopes, especially concerning the role played by thermal inertia in the energy requirements for cooling applications. In fact, a high thermal inertia of the outer walls results in a mitigation of the daily heat wave, which reduces the cooling peak load and the related energy demand. The common assumption that high mass means high thermal inertia typically leads to the use of high-mass blocks. Numerical and experimental studies on thermal inertia of hollow envelope components have not confirmed this general assumption, even though no systematic analysis is readily available in the open literature. Yet, the usually employed methods for the calculation of unsteady heat transfer through walls are based on the hypothesis that such walls are composed of homogeneous layers. In this framework, a study of the dynamic thermal performance of insulated blocks is brought forth in the present paper. A finite-volume method is used to solve the two-dimensional equation of conduction heat transfer, using a triangular-pulse temperature excitation to analyze the heat flux response. The effects of both the type of clay and the insulating filler are investigated and discussed at length. The results obtained show that the wall front mass is not the basic independent variable, since clay and insulating filler thermal diffusivities are more important controlling parameters.
11 July 2019 in International Journal of Numerical Methods for Heat & Fluid Flow
Purpose: The purpose of this study is to investigate numerically the laminar natural convection from a pair of horizontal heated cylinders, set one above the other, inside a water-filled rectangular enclosure cooled at sides, with perfectly insulated top and bottom walls, through a control-volume formulation of the finite-difference method, with the main aim to evaluate the effects of the center-to-center cylinder spacing, the size of the cavity and the temperature difference imposed between the cylinders and the cavity sides. Design/methodology/approach: The system of the conservation equations of the mass, momentum and energy, expressed in dimensionless form, is solved by a specifically developed computer code based on the SIMPLE-C algorithm for the pressure-velocity coupling. Numerical simulations are executed for different values of the Rayleigh number based on the cylinder diameter, as well as the center-to-center cylinder spacing and the width of the cavity normalized by the cylinder diameter. Findings: The main results obtained may be summarized as follows: the existence of an optimum cylinder spacing for maximum heat transfer rate is found at any investigated Rayleigh number; as a consequence of the downstream confinement, a periodic flow arises at sufficiently high Rayleigh numbers; the amplitude of oscillation of the periodic heat transfer performance of the cylinder array decreases as the cylinder spacing is increased and the cavity width is decreased, whereas the frequency of oscillations remains almost the same; at very small cavity widths, a transition from the typical two-cell to a four-cell flow pattern occurs. Originality/value: The computational code used in the present study incorporates an original composite polar/Cartesian discretization grid scheme.