Vincenzo Andrea Spena

Mr. Vincenzo Andrea Spena

DIAEE - University of Rome “Sapienza”
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
ASAngelo Spena
Angelo Spena
Leonardo PalombiLeonardo Palombi
Leonardo Palombi
Massimo CorcioneMassimo Corcione
Massimo Corcione
MCMARIACHIARA CARESTIA
MARIACHIARA CARESTIA
Vincenzo Andrea SpenaVincenzo Andrea Spena
Vincenzo Andrea Spena
In the CoViD-19 pandemic, the precautionary approach suggests that all possible measures should be established and implemented to avoid contagion, including through aerosols. For indoor spaces, the virulence of SARS-CoV-2 could be mitigated not only via air changes, but also by heating, ventilation, and air conditioning (HVAC) systems maintaining thermodynamic conditions possibly adverse to the virus. However, data available in literature on virus survival were never treated aiming to this. In fact, based on comparisons in terms of specific enthalpy, a domain of indoor comfort conditions between 50 and 60 kJ/kg is found to comply with this objective, and an easy-to-use relationship for setting viable pairs of humidity and temperature using a proper HVAC plant is proposed. If confirmed via further investigations on this research path, these findings could open interesting scenarios on the use of indoor spaces during the pandemic.

ASAngelo Spena
Angelo Spena
Leonardo PalombiLeonardo Palombi
Leonardo Palombi
Massimo CorcioneMassimo Corcione
Massimo Corcione
AQAlessandro Quintino
Alessandro Quintino
MCMARIACHIARA CARESTIA
MARIACHIARA CARESTIA
Vincenzo Andrea SpenaVincenzo Andrea Spena
Vincenzo Andrea Spena
Following the coronavirus disease 2019 (COVID-19) pandemic, several studies have examined the possibility of correlating the virulence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the virus that causes COVID-19, to the climatic conditions of the involved sites; however, inconclusive results have been generally obtained. Although neither air temperature nor humidity can be independently correlated with virus viability, a strong relationship between SARS-CoV-2 virulence and the specific enthalpy of moist air appears to exist, as confirmed by extensive data analysis. Given this framework, the present study involves a detailed investigation based on the first 20–30 days of the epidemic before public health interventions in 30 selected Italian provinces with rather different climates, here assumed as being representative of what happened in the country from North to South, of the relationship between COVID-19 distributions and the climatic conditions recorded at each site before the pandemic outbreak. Accordingly, a correlating equation between the incidence rate at the early stage of the epidemic and the foregoing average specific enthalpy of atmospheric air was developed, and an enthalpy-based seasonal virulence risk scale was proposed to predict the potential danger of COVID-19 outbreak due to the persistence of weather conditions favorable to SARS-CoV-2 viability. As an early detection tool, an unambiguous risk chart expressed in terms of coupled temperatures and relative humidity (RH) values was provided, showing that safer conditions occur in the case of higher RHs at the highest temperatures, and of lower RHs at the lowest temperatures. Despite the complex determinism and dynamics of the pandemic and the related caveats, the restriction of the study to its early stage allowed the proposed risk scale to result in agreement with the available infectivity data highlighted in the literature for a number of cities around the world.

22 November 2019 in The European Physical Journal C
Verified
Journal Article
Open access
PDF file
Miguel ArdidMiguel Ardid
Miguel Ardid
ABAndrea Baschirotto
Andrea Baschirotto
NBNunzio Burgio
Nunzio Burgio
Massimo CorcioneMassimo Corcione
Massimo Corcione
LCL. Cretara
L. Cretara
LZL. Zanotti
L. Zanotti
In the framework of the search for dark matter in the form of WIMPs using superheated liquids, a study is conducted to establish a computational procedure aimed at determining how the thermodynamic conditions kept inside a particle detector affect the acoustic signal produced by bubble nucleation. It is found that the acoustic energy injected into the liquid by the growing vapour bubble increases as the liquid pressure is decreased and the superheat degree is increased, the former effect being crucial for the generation of a well-intelligible signal. A good agreement is met between the results of the present study and some experimental data available in the literature for the amplitude of the acoustic signal. Additionally, the higher loudness of the alpha-decay events compared with those arising from neutron-induced nuclear recoils is described in terms of multiple nucleations.

29 January 2021 in Heat Transfer Engineering
Verified
Journal Article
Closed access
Massimo CorcioneMassimo Corcione
Massimo Corcione
LCLuca Cretara
Luca Cretara
AQAlessandro Quintino
Alessandro Quintino
Vincenzo Andrea SpenaVincenzo Andrea Spena
Vincenzo Andrea Spena
Natural convection from a horizontal plate with identically-heated top and bottom sides, enclosed in gas- or liquid-filled square cavities cooled at sides, is studied numerically. A computational code based on the SIMPLE-C algorithm for pressure-velocity coupling is used to solve the system of the governing conservation equations of mass, momentum and energy. Simulations are performed using the Rayleigh number based on the plate length, the Prandtl number, the cavity width normalized by the plate length, and the distance of the plate from the bottom wall of the enclosure normalized by the cavity width, as controlling parameters. It is found that the heat transfer rate enhances as the Rayleigh number, the Prandtl number and the dimensionless size of the cavity are increased, while it deteriorates as the dimensionless elevation of the plate is increased. Additionally, the heating of the upper side of the plate has an almost imperceptible effect on the heat transfer rate at the lower side of the plate, whereas the amount of heat transferred from the upper side of the plate normally decreases when the lower side of the plate is heated rather than being insulated. Based on the results obtained, suitable dimensionless heat transfer correlations are developed for the entire plate and each heated side.

11 July 2019 in International Journal of Numerical Methods for Heat & Fluid Flow
Verified
Journal Article
Closed access
MCMarta Cianfrini
Marta Cianfrini
Massimo CorcioneMassimo Corcione
Massimo Corcione
AQAlessandro Quintino
Alessandro Quintino
Vincenzo Andrea SpenaVincenzo Andrea Spena
Vincenzo Andrea Spena
Purpose: The purpose of this study is to investigate numerically the laminar natural convection from a pair of horizontal heated cylinders, set one above the other, inside a water-filled rectangular enclosure cooled at sides, with perfectly insulated top and bottom walls, through a control-volume formulation of the finite-difference method, with the main aim to evaluate the effects of the center-to-center cylinder spacing, the size of the cavity and the temperature difference imposed between the cylinders and the cavity sides. Design/methodology/approach: The system of the conservation equations of the mass, momentum and energy, expressed in dimensionless form, is solved by a specifically developed computer code based on the SIMPLE-C algorithm for the pressure-velocity coupling. Numerical simulations are executed for different values of the Rayleigh number based on the cylinder diameter, as well as the center-to-center cylinder spacing and the width of the cavity normalized by the cylinder diameter. Findings: The main results obtained may be summarized as follows: the existence of an optimum cylinder spacing for maximum heat transfer rate is found at any investigated Rayleigh number; as a consequence of the downstream confinement, a periodic flow arises at sufficiently high Rayleigh numbers; the amplitude of oscillation of the periodic heat transfer performance of the cylinder array decreases as the cylinder spacing is increased and the cavity width is decreased, whereas the frequency of oscillations remains almost the same; at very small cavity widths, a transition from the typical two-cell to a four-cell flow pattern occurs. Originality/value: The computational code used in the present study incorporates an original composite polar/Cartesian discretization grid scheme.

5 October 2020 in Preprints.org
Verified
Preprint
Open access
ASAngelo Spena
Angelo Spena
Leonardo PalombiLeonardo Palombi
Leonardo Palombi
Massimo CorcioneMassimo Corcione
Massimo Corcione
AQAlessandro Quintino
Alessandro Quintino
MCMARIACHIARA CARESTIA
MARIACHIARA CARESTIA
Vincenzo Andrea SpenaVincenzo Andrea Spena
Vincenzo Andrea Spena
Following the coronavirus disease 2019 (COVID-19) pandemic, several studies have examined the possibility of correlating the virulence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the virus that causes COVID-19, to the climatic conditions of the involved sites; however, inconclusive results have been generally obtained. Although either air temperature or humidity cannot be independently correlated with virus viability, a strong relationship between SARS-CoV-2 virulence and the specific enthalpy of moist air appears to exist, as confirmed by extensive data analysis. Given this framework, the present study involves a detailed investigation based on the first 20–30 days of the epidemic before public health interventions in 30 selected Italian provinces with rather different climates, here assumed as being representative of what happened in the country from North to South, of the relationship between COVID-19 distributions and the climatic conditions recorded at each site before the pandemic outbreak. Accordingly, a correlating equation between the incidence rate of the pandemic and the average specific enthalpy of atmospheric air was developed, and an enthalpy-based seasonal virulence risk scale was proposed as a tool to predict the potential danger of COVID-19 spread due to the persistence of weather conditions favorable to SARS-CoV-2 viability. For practical applications, a conclusive risk chart expressed in terms of coupled temperatures and relative humidity (RH) values was provided, showing that safer conditions occur in case of higher RH at the highest temperatures, and of lower RH at the lowest temperatures. The proposed risk scale was in agreement with the available infectivity data in the literature for a number of cities around the world.