Muhammad Usama

Dr. Muhammad Usama

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 October 2023 in Renewable Energy
Verified
Journal Article
Closed access
MUMuhammad Usama
Muhammad Usama
AZAli Zaib
Ali Zaib
MNMacmanus C. Ndukwu
Macmanus C. Ndukwu
Ravishankar SathyamurthyRavishankar Sathyamurthy
Ravishankar Sathyamurthy

29 December 2022 in Research Square
Verified
Preprint
Open access
PDF file
MUMuhammad Usama
Muhammad Usama
MAMuhammad Ali
Muhammad Ali
KHKhizar Hayat
Khizar Hayat
AAAmmar Ahmad
Ammar Ahmad
ZAZaib Ali
Zaib Ali
Solar hot air drying is a food dehydration method that is quickly gaining traction in South Asia due to its very low capital and operational cost. The long drying time and high temperature are the primary sinks of product quality in this process. The deterioration of cosmetic quality of food due to exposure to high temperatures over prolonged durations is an economical challenge as well since it results in a portion of dried product to be discarded. The objective of this work was to reduce the energy consumption and drying time, while obtaining a product quality competitive with energy extensive methods. To achieve this objective, a combined desiccant-convection-radiation dryer was designed and tested. A solar powered thermally regenerated desiccant dehumidifier was installed upstream of a Hot air – Microwave combined food dehydrator. The experimental results were compared with and without desiccant dehumidification. ‘Solanum tuberosum’ potato was cut into 3 mm thick slices and identical control samples of the potato slices were dehydrated using Hot air drying at 60 oC, Microwave drying at 1 kW Microwave power, Combined Hot air – Microwave drying, and Desiccant assisted Microwave – Convection drying. The drying time of the control sample with Desiccant assisted Hot air – Microwave drying was found to be the lowest, resulting in 81.7% reduction in drying time compared to Hot air Convection drying, 27.7% compared to MW drying and 13.3% compared to Microwave – Convection drying. The color retention was also found to be the highest for Desiccant assisted Microwave – Convection drying. The dried potato slices preserved 87.8% of their original color with this method, which is comparable to the results that are obtained with Freeze Drying.

27 January 2026 in Innovative Food Science & Emerging Technologies
Verified
Journal Article
Closed access
MUMuhammad Usama
Muhammad Usama
ZAZaib Ali
Zaib Ali
AIAashir Iqbal
Aashir Iqbal
macmanus Chinenye ndukwumacmanus Chinenye ndukwu
macmanus Chinenye ndukwu

16 June 2026 in Food and Bioproducts Processing
Verified
Journal Article
Closed access
MUMuhammad Usama
Muhammad Usama
AZAli Zaib
Ali Zaib
MNMacmanus C. Ndukwu
Macmanus C. Ndukwu
WMWaseem Mushtaq
Waseem Mushtaq
AIAashir Iqbal
Aashir Iqbal
TRTAHMID HASAN RUPAM
TAHMID HASAN RUPAM

22 October 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
MUMuhammad Usama
Muhammad Usama
MGMuhammad Abdullah Zafar Ghauri
Muhammad Abdullah Zafar Ghauri
AOAditya Oswal
Aditya Oswal
The Middle East, including the six Gulf Cooperation Council (GCC) states, is among the world's fastest-growing data center regions. Its live IT capacity, about 1.2 GW in 2025, is forecast to grow by roughly 60% a year, and projects announced across the Middle East and North Africa exceed 14 GW, against about 5 GW expected by 2030. The main GCC hubs face dry-bulb temperatures of about 43-46 • C, wet-bulb temperatures near 31 • C, seawater temperatures above 35 • C in the summer, regular dust storms, and mostly desalinated municipal water. This is the first review to combine climate, deployment, power, cooling, water, and waste-heat data for the region. Cooling with outside air works only in winter, when savings are small, and coastal summer air is too humid to bring indoors. Cooling towers work all year, even on the humid coast, but consume water. Liquid cooling with warm water is the most promising way to avoid both chillers and water use for most of the year, if the servers accept warm water. The Red Sea and Omani coasts, unlike the Persian Gulf, offer cool deep seawater. The region's large district cooling networks, some supplied with treated wastewater, remain largely untapped by data centers. At Gulf prices, evaporative cooling costs less to run than dry cooling, even with desalinated water, whenever dry cooling would raise energy use by more than about 3-9%. The real water constraint is how desalinated water is allocated and delivered at summer peaks, not its price. Data center waste heat has no heating market but could drive cooling or desalination, although desalination driven by data center heat has yet to be demonstrated in the field.

9 November 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
MUMuhammad Usama
Muhammad Usama
MGMuhammad Abdullah Zafar Ghauri
Muhammad Abdullah Zafar Ghauri
Data centers convert nearly all their electricity into heat, and the growth of artificial intelligence (AI) is concentrating this heat in large campuses near cities. District heating networks can use it, but utilisation depends on their size and temperature, the seasonal pattern of demand and data center cooling. An hourly model linked a 100 MW AI campus, through heat exchangers and large heat pumps, to third and fourth generation district heating networks in 26 cities in Europe, North America and East Asia. Air, direct-to-chip and immersion cooling were compared under present and 2041 to 2060 climates from 34 global climate models. To reach 90% utilisation of captured data center heat, annual district heating network demand had to be 1.6 to 3.8 times the annual information technology energy of an air-cooled campus and about 11% less with direct-to-chip cooling. The summer share of demand explained the ranking of cities better than heating degree days (Spearman rank correlation-0.91 against-0.43). Mid-century warming lowered district heating network demand by 5 to 13% and raised the required district heating network size by up to 25%. Liquid cooling cut heat-pump electricity by 46 and 68% in third and fourth generation district heating networks. In 13 cities with reported data, existing district heating networks could use 14 to 31% of captured data center heat in London, Amsterdam and Frankfurt and all of it in Berlin, Warsaw, Munich, New York and Beijing. Planned capacity lowered utilisation to 3 to 8% in the first three cities.