A new micro heat exchanger was analyzed using numerical formulation of conjugate heat transfer for single-phase fluid flow across copper microchannels. The flow across bent channels harnesses asymmetric laminar flow and dean vortices phenomena for heat transfer enhancement. The single-channel analysis was performed to select the bent channel aspect ratio by varying width and height between 35–300 μm for Reynolds number and base temperature magnitude range of 100–1000 and 320–370 K, respectively. The bent channel results demonstrate dean vortices phenomenon at the bend for Reynolds number of 500 and above. Thermal performance factor analysis shows an increase of 18% in comparison to straight channels of 200 μm width and height. Alumina nanoparticles at 1% and 3% concentration enhance the Nusselt number by an average of 10.4% and 23.7%, respectively, whereas zirconia enhances Nusselt number by 16% and 33.9% for same concentrations. On the other hand, thermal performance factor analysis shows a significant increase in pressure drop at high Reynolds number with 3% particle concentration. Using zirconia for nanofluid, Nusselt number of the bent multi-channel model is improved by an average of 18% for a 3% particle concentration as compared to bent channel with deionized water.
Seawater desalination is an affordable and viable solution to the growing freshwater scarcity problem in water scarce regions. The current study focuses on cost analysis of Vacuum Membrane Distillation (VMD) setup for removing salts from water. The membrane used in the flat sheet VMD module was Polytetrafluoroethylene (PTFE) with 250 mm × 200 mm dimensions and 165 µm thickness. The experiments were carried out with variations in parameters such as velocity, pressure, concentration, and temperature. For the cost analysis, the operational, maintenance, instrumentation, and capital cost of the lab model was considered and then upscaled. A range of experiments was performed for NaCl and KCl under variations of operating parameters. It was noted that, for the NaCl solution, the increase in temperature from 50 °C to 70 °C doubled the permeate flux. However, for the conditions tested, the concentration shift from 0.25 M to 0.75 M decreased the permeate flux by 1.4% because the increase in ion concentrations along the membrane lowers the vapor pressure, restricting the permeate flux. The results trend for the KCl solution was similar to the NaCl; at temperature T1, it was noted that increased concentration from 0.25 M to 0.75 M significantly reduces the permeate flow. The reduction in permeate flow was nonlinear for a given pressure 30 kPa and velocity 5.22 m/s, but linear for all other variables. It was also observed that with an increase in temperature from 60 °C to 70 °C, the permeate flux for concentration 0.25 M was 49% for all the combinations of pressure and velocity. In addition, permeate flow increased 53% from temperature 50 °C to 60 °C and 49% from temperature 60 °C to 70 °C for both the solutions at a concentration of 0.25 M. This shows that the temperature also had a profound impact on the permeate flux. The economic analysis and market survey shows that the cost of clean water at the lab level was high which can be significantly reduced using a large-scale setup providing 1,000,000 L/H of distilled water.
17 February 2022 in Journal of Building Performance Simulation
Climate change and the urban heat island (UHI) effects are increasing heat stress and adversely impacting outdoor thermal comfort in urban areas. The study demonstrates that thermal comfort conditions can be improved by reducing air temperature and surface temperature with the integration of street trees into the urban environment. In this work, computational fluid dynamics (CFD) simulations using unsteady Reynolds-averaged Navier–Stokes (URANS) equations have been performed to analyze the cooling effect of street trees for heatwave period (18–22 June 2015) in a hot-humid urban environment. The results are then compared in-term-of air/surface temperature, flow-velocity and apparent temperature for the vegetation case, open-space case, and built case. The analysis shows that the vegetation can effectively decrease surrounding temperature (a reduction of 1.2 K), thereby reducing energy consumption and effectively promote thermal comfort conditions. The study findings will encourage city planners and citizens to take action for urban greening.
In this study, the pressure drop and heat transfer characteristics of smooth tube and internal helically micro-finned tubes with two different fin-to-fin height ratios i.e., equal fin height and alternating fin height, are computationally analysed. The tube with alternating fin height is analysed for proof of concept of pressure drop reduction. A single phase steady turbulent flow model is used with a Reynolds number ranging from 12,000 to 54,000. Water is used as working fluid with inlet temperature of 55 °C and constant wall temperature of 20 °C is applied. Friction factor, heat transfer coefficient, Nusselt number, and Thermal Performance Index are evaluated and analysed. The numerical results are validated by comparison with the experimental and numerical data from literature. The results showed that the thermal performance is enhanced due to helically finned tube for a range of Reynolds numbers, but at the expense of increased pressure drop as compared to a smooth tube. The helically finned tube with alternating fin heights showed a 5% decrease in friction factor and <1% decrease in heat transfer coefficient when compared with the equal fin heights tube, making it a suitable choice for heat transfer applications.