shiyong LI

Dr. shiyong LI

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 February 2022 in RSC Advances
Verified
Journal Article
Open access
PDF file
TZTao Zhan
Tao Zhan
XFXiao-Zhen Feng
Xiao-Zhen Feng
QAQi-Qi An
Qi-Qi An
SLshiyong LI
shiyong LI
MXMingyue Xue
Mingyue Xue
HKHeinz-Bernhard Kraatz
Heinz-Bernhard Kraatz
Gold electrodes (GE) were modified by the deposition of copper nanoparticles (CuNPs) and cobalt nanoparticles (CoNPs), followed by drop-casting of the ferrocene derivative FcCO-Glu-Cys-Gly-OH (Fc-ECG), resulting in two enzyme-free electrochemical sensors Fc-ECG/CuNPs/GE and Fc-ECG/CuNPs/GE. The ferrocene-peptide conjugate acts as an effective redox mediator for glucose oxidation, while metal nanoparticles acted as non-biological sites for glucose oxidation. Field emission scanning electron microscopy (FESEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were carried out for characterization, while differential pulse voltammetry (DPV) was used for glucose quantification. Under optimized conditions, DPV shows a linear relationship between glucose concentration and the peak current. Both sensors showed a surprisingly high sensitivity of 217.27 and 378.70 μA mM−1 cm−2, respectively. A comparison to other glucose sensors shows a sensitivity that is 25 times higher. The sensors exhibit good reproducibility, stability, and repeatability. In injection experiments, recovery rates were 87.39–107.65% and 100.00–106.88%, respectively.

12 March 2023 in Electronics
Verified
Journal Article
Open access
PDF file
ZCZhengcheng Chen
Zhengcheng Chen
HQHuishan Qin
Huishan Qin
WGWenjun Ge
Wenjun Ge
SLshiyong LI
shiyong LI
YLYongbo Liang
Yongbo Liang
Hemoglobin is an essential parameter in human blood. This paper proposes a non-invasive hemoglobin concentration measurement method based on the characteristic parameters of four-wavelength photoplethysmography (PPG) signals combined with machine learning. The DCM08 sensor and NRF52840 chip form a data acquisition system to collect 58 human fingertip photoelectric volumetric pulse wave signals. The 160 four-wavelength PPG signal feature parameters were constructed and extracted. The feature parameters were screened by combining three feature selection methods: reliefF, Chi-square score, and information gain. The top 10, 20, and 30 features screened were used as input to evaluate the prediction performance of different feature sets for hemoglobin. The prediction models used were XGBoost, support vector machines, and logistic regression. The results showed that the optimal performance of the 30 feature sets screened using the Chi-square test was achieved by the XGBoost model with a coefficient of determination (R2) of 0.997, root mean square error (RMSE) of 0.762 g/L, and mean absolute error (MAE) of 0.325 g/L. The study showed that the four-wavelength-based PPG signal feature parameters with the XGBoost algorithm could effectively achieve non-invasive detection of hemoglobin, providing a new measurement method in clinical practice.

5 February 2024 in Electronics
Verified
Journal Article
Open access
PDF file
YWYankun Wu
Yankun Wu
QTQunfeng Tang
Qunfeng Tang
WZWeizong Zhan
Weizong Zhan
SLshiyong LI
shiyong LI
ZCZhengcheng Chen
Zhengcheng Chen
Arrhythmias are among the most prevalent cardiac conditions and frequently serve as a direct cause of sudden cardiac death. Hence, the automated detection of arrhythmias holds significant importance for assisting in the diagnosis of heart conditions. Recently, the photoplethysmography (PPG) signal, capable of conveying heartbeat information, has found application in the field of arrhythmia detection research. This work proposes a hybrid deep learning model, Res-BiANet, designed for the detection and classification of multiple types of arrhythmias. The improved ResNet and BiLSTM models are connected in parallel, and spatial and temporal features of PPG signals are extracted using ResNet and BiLSTM, respectively. Subsequent to BiLSTM, a multi-head self-attention mechanism was incorporated to enhance the extraction of global temporal correlation features over long distances. The model classifies five types of arrhythmia rhythms (premature ventricular contractions, premature atrial contractions, ventricular tachycardia, supraventricular tachycardia, and atrial fibrillation) and normal rhythm (sinus rhythm). Based on this foundation, experiments were conducted utilizing publicly accessible datasets, encompassing a total of 46,827 PPG signal fragments from 91 patients with arrhythmias. The experimental results demonstrate that Res-BiANet achieved exceptional classification performance, including an F1 score of 86.88%, overall accuracy of 92.38%, and precision, sensitivity, and specificity of 88.46%, 85.15%, and 98.43%, respectively. The outstanding performance of the Res-BiANet model suggests significant potential in supporting the auxiliary diagnosis of multiple types of arrhythmias.

25 March 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
MCMou Cui
Mou Cui
XDXuhao Dong
Xuhao Dong
YZYan Zhuang
Yan Zhuang
SLshiyong LI
shiyong LI
SYShimin Yin
Shimin Yin
YLYongbo Liang
Yongbo Liang
As an essential physiological indicator within the human body, noninvasive continuous blood pressure (BP) measurement is critical in the prevention and treatment of cardiovascular disease. However, traditional methods of blood pressure prediction using a single-wavelength Photoplethysmographic (PPG) have bottlenecks in further improving BP prediction accuracy, which limits their development in clinical application and dissemination. To this end, this study proposed a method to fuse a four-wavelength PPG and a BP prediction model based on the attention mechanism of a convolutional neural network and bidirectional long- and short-term memory (ACNN-BiLSTM). The effectiveness of a multi-wavelength PPG fusion method for blood pressure prediction was evaluated by processing PPG signals from 162 volunteers. The study compared the performance of the PPG signals with different individual wavelengths and using a multi-wavelength PPG fusion method in blood pressure prediction, assessed using mean absolute error (MAE), root mean squared error (RMSE) and AAMI-related criteria. The experimental results showed that the ACNN-BiLSTM model achieved a better MAE ± RMSE for a systolic BP and diastolic BP of 1.67 ± 5.28 and 1.15 ± 2.53 mmHg, respectively, when using the multi-wavelength PPG fusion method. As a result, the ACNN-BiLSTM blood pressure model based on multi-wavelength PPG fusion could be considered a promising method for noninvasive continuous BP measurement.

10 May 2024 in Electronics
Verified
Journal Article
Open access
PDF file
YGYanke GUO
Yanke GUO
QTQunfeng Tang
Qunfeng Tang
ZCZhengcheng Chen
Zhengcheng Chen
SLshiyong LI
shiyong LI
Electrocardiography (ECG) is generally used in clinical practice for cardiovascular diagnosis and for monitoring cardiovascular status. It is considered to be the gold standard for diagnosing cardiovascular diseases and assessing cardiovascular status. However, it is not always easy to obtain. Unlike ECG devices, photoplethysmography (PPG) devices can be placed on body parts such as the earlobes, fingertips, and wrists, making them more comfortable and easier to obtain. Several methods for reconstructing ECG signals using PPG signals have been proposed, but some of these methods are subject-specific models. These models cannot be applied to multiple subjects and have limitations. This study proposes a neural network model based on UNet and bidirectional long short-term memory (BiLSTM) networks as a group model for reconstructing ECG from PPG. The model was verified using 125 records from the MIMIC III matched subset. The experimental results demonstrated that the proposed model was, on average, able to achieve a Pearson‘s correlation coefficient, root mean square error, percentage root mean square difference, and Fréchet distance of 0.861, 0.077, 5.302, and 0.278, respectively. This research can use the correlation between PPG and ECG to reconstruct a better ECG signal from PPG, which is crucial for diagnosing cardiovascular diseases.

11 April 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
YGYanke GUO
Yanke GUO
QTQunfeng Tang
Qunfeng Tang
SLshiyong LI
shiyong LI
ZCZhengcheng Chen
Zhengcheng Chen
ECG helps in diagnosing heart disease by recording heart activity. During long-term measurements, data loss occurs due to sensor detachment. Therefore, research into the reconstruction of missing ECG data is essential. However, ECG requires user participation and cannot be used for continuous heart monitoring. Continuous monitoring of PPG signals is conversely low-cost and easy to carry out. In this study, a deep neural network model is proposed for the reconstruction of missing ECG signals using PPG data. This model is an end-to-end deep learning neural network utilizing WNet architecture as a basis, on which a bidirectional long short-term memory network is added in establishing a second model. The performance of both models is verified using 146 records from the MIMIC III matched subset. Compared with the reference, the ECG reconstructed using the proposed model has a Pearson’s correlation coefficient of 0.851, root mean square error (RMSE) of 0.075, percentage root mean square difference (PRD) of 5.452, and a Fréchet distance (FD) of 0.302. The experimental results demonstrate that it is feasible to reconstruct missing ECG signals from PPG.