Yan Zhuang

Dr. Yan Zhuang

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 March 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
MCMou Cui
Mou Cui
XDXuhao Dong
Xuhao Dong
YZYan Zhuang
Yan Zhuang
SLshiyong LI
shiyong LI
SYShimin Yin
Shimin Yin
YLYongbo Liang
Yongbo Liang
As an essential physiological indicator within the human body, noninvasive continuous blood pressure (BP) measurement is critical in the prevention and treatment of cardiovascular disease. However, traditional methods of blood pressure prediction using a single-wavelength Photoplethysmographic (PPG) have bottlenecks in further improving BP prediction accuracy, which limits their development in clinical application and dissemination. To this end, this study proposed a method to fuse a four-wavelength PPG and a BP prediction model based on the attention mechanism of a convolutional neural network and bidirectional long- and short-term memory (ACNN-BiLSTM). The effectiveness of a multi-wavelength PPG fusion method for blood pressure prediction was evaluated by processing PPG signals from 162 volunteers. The study compared the performance of the PPG signals with different individual wavelengths and using a multi-wavelength PPG fusion method in blood pressure prediction, assessed using mean absolute error (MAE), root mean squared error (RMSE) and AAMI-related criteria. The experimental results showed that the ACNN-BiLSTM model achieved a better MAE ± RMSE for a systolic BP and diastolic BP of 1.67 ± 5.28 and 1.15 ± 2.53 mmHg, respectively, when using the multi-wavelength PPG fusion method. As a result, the ACNN-BiLSTM blood pressure model based on multi-wavelength PPG fusion could be considered a promising method for noninvasive continuous BP measurement.

27 March 2024 in Electronics
Verified
Journal Article
Open access
PDF file
HZHan Zhang
Han Zhang
ZWZiyi Wang
Ziyi Wang
YZYan Zhuang
Yan Zhuang
SYShimin Yin
Shimin Yin
ZCZhengcheng Chen
Zhengcheng Chen
YLYongbo Liang
Yongbo Liang
Mental workload is an important predisposing factor for mental illnesses such as depression and is closely related to individual mental health. However, the suboptimal accuracy of utilizing photoplethysmography (PPG) exclusively for mental workload classification has constrained its application within pertinent professional domains. To this end, this paper proposes a signal processing method that combines continuous wavelet transform (CWT) and cardiopulmonary coupling mapping (CPC) to classify mental load via a convolutional neural network (ResAttNet). The method reflects changes in mental workload, as assessed by changes in the association between heart rate variability and respiration. In this paper, the strengths and weaknesses of this method are compared with other traditional psychological workload monitoring methods, such as heart rate variability (HRV), and its validation is performed on the publicly available dataset MAUS. The experiments show that the method is significantly better than previous machine learning methods based on heart rate variability correlation. Meanwhile, the accuracy of the method proposed in this paper reaches 80.5%, which is 6.2% higher than in previous studies. It is comparable to the result of 82.4% for the ECG-based mental workload monitoring system. Therefore, the method of combining CWT and CPC has considerable potential and provides new ideas for mental workload classification.

1 February 2025 in Algorithms
Verified
Journal Article
Open access
PDF file
LLLei Liu
Lei Liu
ZWZiyi Wang
Ziyi Wang
XZXiaohan Zhang
Xiaohan Zhang
YZYan Zhuang
Yan Zhuang
YLYongbo Liang
Yongbo Liang
Non-invasive haemoglobin (Hb) testing devices enable large-scale haemoglobin screening, but their accuracy is not comparable to traditional blood tests. To this end, this paper aims to design a non-invasive haemoglobin testing device and propose a classification-regression prediction framework for non-invasive testing of haemoglobin using visibility graphs (VG) with network clustering of multi-sample pulse-wave-weighted undirected graphs as the features to optimize the detection accuracy of non-invasive haemoglobin measurements. Different prediction methods were compared by analyzing 608 segments of multiwavelength fingertip PPG signal data from 152 volunteers and analyzing and comparing the data and methods. The results showed that the classification using NVG with complex network clustering as features in the interval classification model was the best, with its classification accuracy (acc) of 93.35% and model accuracy of 88.28%. Among the regression models, the classification regression stack: SVM-Light Gradient Boosting Machine (LGBM) was the most effective, with a Mean Absolute Error (MAE) of 6.67 g/L, a Root Mean Square Error (RMSE) of 8.21 g/L, and an R-Square (R2) of 0.64. The results of this study indicate that the use of complex network technology in non-invasive haemoglobin detection can effectively improve its accuracy, and the detector designed in this study is promising to carry out a more accurate large-scale haemoglobin screening.