Ali Kight

Ms. Ali Kight


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 January 2020 in IEEE Transactions on Haptics
Verified
Journal Article
Closed access
SFSamuel Frishman
Samuel Frishman
AKAli Kight
Ali Kight
IPIleana Pirozzi
Ileana Pirozzi
MCMela C. Coffey
Mela C. Coffey
BDBruce L. Daniel
Bruce L. Daniel
MCMark R. Cutkosky
Mark R. Cutkosky
Limited physical access to target organs of patients inside an MRI scanner is a major obstruction to real-time MRI-guided interventions. Traditional teleoperation technologies are incompatible with the MRI environment and although several solutions have been explored, a versatile system that provides high-fidelity haptic feedback and access deep inside the bore remains a challenge. We present a passive and nearly frictionless MRI-compatible hydraulic teleoperator designed for in-bore liver biopsies. We describe the design components, characterize the system transparency, and evaluate the performance with a user study in a laboratory and a clinical setting. The results demonstrate <5% difference between input and output forces during realistic manipulation. A user study with participants conducting mock needle biopsy tasks indicates that a remote operator performs equally well when using the device as when holding a biopsy needle directly in hand. Additionally, MRI compatibility tests show no reduction in signal-to-noise ratio in the presence of the device.

23 July 2023 in Advanced Materials
Verified
Journal Article
Open access
IPIleana Pirozzi
Ileana Pirozzi
AKAli Kight
Ali Kight
AHAmy Kyungwon Han
Amy Kyungwon Han
MCMark R. Cutkosky
Mark R. Cutkosky
SDSeraina Anne Dual
Seraina Anne Dual
Artificial muscles enable the design of soft implantable devices which are poised to transform the way we mechanically support the heart today. Heart failure is a prevalent and deadly disease, which is treated with the implantation of rotary blood pumps as the only alternative to heart transplantation. The clinically used mechanical devices are associated with severe adverse events, which are reflected here in a comprehensive list of critical requirements for soft active devices of the future: low power, no blood contact, pulsatile support, physiological responsiveness, high cycle life, and less‐invasive implantation. In this review, prior art in artificial muscles for their applicability in the short and long term is investigated and critically evaluated. The main challenges regarding the effectiveness, controllability, and implantability of recently proposed actuators are highlighted and the future perspectives for attachment, physiological responsiveness, durability, and biodegradability as well as equitable design considerations are explored.

9 February 2022 in Advanced Materials Technologies
Verified
Journal Article
Closed access
PDF file
IPIleana Pirozzi
Ileana Pirozzi
AKAli Kight
Ali Kight
RSRohan A. Shad
Rohan A. Shad
AHAmy Kyungwon Han
Amy Kyungwon Han
SDSeraina A. Dual
Seraina A. Dual
MCMark Cutkosky
Mark Cutkosky

9 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
AKAli Kight
Ali Kight
IPIleana Pirozzi
Ileana Pirozzi
XLXinyi Liang
Xinyi Liang
DMDoff B. McElhinney
Doff B. McElhinney
AHAmy Kyungwon Han
Amy Kyungwon Han
MCMark Cutkosky
Mark Cutkosky
This work presents a modular approach to the development of strain sensors for large deformations. The proposed method separates the extension and signal transduction mechanisms using a soft, elastomeric transmission and a high-sensitivity microelectromechanical system (MEMS) transducer. By separating the transmission and transduction, they can be optimized independently for application-specific mechanical and electrical performance. This work investigates the potential of this approach for human health monitoring as an implantable cardiac strain sensor for measuring global longitudinal strain (GLS). The durability of the sensor was evaluated by conducting cyclic loading tests over one million cycles, and the results showed negligible drift. To account for hysteresis and frequency-dependent effects, a lumped-parameter model was developed to represent the viscoelastic behavior of the sensor. Multiple model orders were considered and compared using validation and test data sets that mimic physiologically relevant dynamics. Results support the choice of a second-order model, which reduces error by 73% compared to a linear calibration. In addition, we evaluated the suitability of this sensor for the proposed application by demonstrating its ability to operate on compliant, curved surfaces. The effects of friction and boundary conditions are also empirically assessed and discussed.

18 May 2022 in Journal of Medical Devices
Verified
Journal Article
Closed access
PDF file
SFSamuel Frishman
Samuel Frishman
AKAli Kight
Ali Kight
IPIleana Pirozzi
Ileana Pirozzi
SMSainiteesh Maddineni
Sainiteesh Maddineni
AIAnnabel Imbrie-Moore
Annabel Imbrie-Moore
MCMark R. Cutkosky
Mark R. Cutkosky
Annuloplasty ring choice and design are critical to the long-term efficacy of mitral valve (MV) repair. DynaRing is a selectively compliant annuloplasty ring composed of varying stiffness elastomer segments, a shape-set nitinol core, and a cross diameter filament. The ring provides sufficient stiffness to stabilize a diseased annulus while allowing physiological annular dynamics. Moreover, adjusting elastomer properties provides a mechanism for effectively tuning key MV metrics to specific patients. We evaluate the ring embedded in porcine valves with an ex-vivo left heart simulator and perform a 150 million cycle fatigue test via a custom oscillatory system. We present a patient-specific design approach for determining ring parameters using a finite element model optimization and patient MRI data. Ex-vivo experiment results demonstrate that motion of DynaRing closely matches literature values for healthy annuli. Findings from the patient-specific optimization establish DynaRing's ability to adjust the anterior–posterior and intercommissural diameters and saddle height by up to 8.8%, 5.6%, 19.8%, respectively, and match a wide range of patient data.

3 May 2025 in npj Biomedical Innovations
Verified
Journal Article
Open access
PDF file
AKAli Kight
Ali Kight
MHMoussa Haidar
Moussa Haidar
MSMasafumi Shibata
Masafumi Shibata
YOYoshikazu Ono
Yoshikazu Ono
GIGentaro Ikeda
Gentaro Ikeda
MCMark Cutkosky
Mark Cutkosky
Heart Failure (HF) is a global epidemic, with high readmission rates and significant morbidity persisting due to gaps in post-acute care.Traditional follow-up often misses gradual postoperative cardiac deterioration occurring outside hospital settings. While advances in remote patient monitoring show promise, practical, continuous, and sensitive methods remain lacking. Building on previous work introducing a durable, soft strain sensor, this research presents VITALS, an implantable strain sensing network that enables continuous biventricular, multiaxial monitoring of cardiac function. The sensor’s design demonstrates improved fatigue life in bechtop testing compared to other soft, large-deformation strain sensors, while effectively minimizing shear loading effects to enhance accuracy. Additionally, the network integrates a sensor on the aorta for synchronous systolic pressure monitoring. Acute animal studies demonstrate the potential of VITALS’ to track epicardial strain, detect preload changes rapidly, and differentiate inotropic states. Validation against echocardiographic chamber volumes and GLS provides preliminary support of the sensor’s clinical relevance.