Annabel Imbrie-Moore

Ms. Annabel Imbrie-Moore

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2011 in Earth and Planetary Science Letters
Verified
Journal Article
Closed access
JIJohn Z. Imbrie
John Z. Imbrie
AIAnnabel Imbrie-Moore
Annabel Imbrie-Moore
LLLorraine E. Lisiecki
Lorraine E. Lisiecki

1 August 2019 in The Journal of Thoracic and Cardiovascular Surgery
Verified
Journal Article
Open access
MPMichael Paulsen
Michael Paulsen
PKPatpilai Kasinpila
Patpilai Kasinpila
AIAnnabel Imbrie-Moore
Annabel Imbrie-Moore
HWHanjay Wang
Hanjay Wang
CHCamille E. Hironaka
Camille E. Hironaka
YWY. Joseph Woo
Y. Joseph Woo
The optimal conduit for valve-sparing aortic root replacement is still debated, with several conduit variations available, ranging from straight tubular grafts to Valsalva grafts. Benefits of neosinus reconstruction include enhanced flow profiles and improved hemodynamics. Curiously, however, some clinical data suggest that straight grafts may have greater long-term durability. In this study, we hypothesized that straight tubular grafts may help maintain the native cylindrical position of the aortic valve commissures radially, resulting in preserved leaflet coaptation, reduced stresses, and potentially improved valve performance. Using 3D printing, a left heart simulator with a valve-sparing root replacement model and a physiologic coronary circulation was constructed. Aortic valves were dissected from fresh porcine hearts and reimplanted into either straight tubular grafts (n = 6) or Valsalva grafts (n = 6). Conduits were mounted into the heart simulator and hemodynamic, echocardiographic, and high-speed videometric data were collected. Hemodynamic parameters and coronary blood flow were similar between straight and Valsalva grafts, although the former were associated with lower regurgitant fractions, less peak intercommissural radial separation, preserved leaflet coaptation, decreased leaflet velocities, and lower relative leaflet forces compared with Valsalva grafts. Valsalva grafts and straight grafts perform equally well in terms of gross hemodyanics and coronary blood flow. Interestingly, however, the biomechanics of these 2 conduits differ considerably, with straight grafts providing increased radial commissural stability and leaflet coaptation. Further investigation into how these parameters influence clinical outcomes is warranted.

1 July 2019 in The Annals of Thoracic Surgery
Verified
Journal Article
Closed access
AIAnnabel Imbrie-Moore
Annabel Imbrie-Moore
MPMichael J. Paulsen
Michael J. Paulsen
ATAkshara D. Thakore
Akshara D. Thakore
HWHanjay Wang
Hanjay Wang
CHCamille E. Hironaka
Camille E. Hironaka
YWY. Joseph Woo
Y. Joseph Woo

1 October 2019 in Journal of Biomechanical Engineering
Verified
Journal Article
Open access
PDF file
MPMichael Paulsen
Michael Paulsen
JBJung Hwa Bae
Jung Hwa Bae
AIAnnabel Imbrie-Moore
Annabel Imbrie-Moore
HWHanjay Wang
Hanjay Wang
CHCamille E. Hironaka
Camille E. Hironaka
YWY. Joseph Woo
Y. Joseph Woo
Few technologies exist that can provide quantitative data on forces within the mitral valve apparatus. Marker-based strain measurements can be performed, but chordal geometry and restricted optical access are limitations. Foil-based strain sensors have been described and work well, but the sensor footprint limits the number of chordae that can be measured. We instead utilized fiber Bragg grating (FBG) sensors—optical strain gauges made of 125 μm diameter silica fibers—to overcome some limitations of previous methods of measuring chordae tendineae forces. Using FBG sensors, we created a force-sensing neochord (FSN) that mimics the natural shape and movement of native chordae. FBG sensors reflect a specific wavelength of light depending on the spatial period of gratings. When force is applied, the gratings move relative to one another, shifting the wavelength of reflected light. This shift is directly proportional to force applied. The FBG sensors were housed in a protective sheath fashioned from a 0.025 in. flat coil, and attached to the chordae using polytetrafluoroethylene suture. The function of the force-sensing neochordae was validated in a three-dimensional (3D)-printed left heart simulator, which demonstrated that FBG sensors provide highly sensitive force measurements of mitral valve chordae at a temporal resolution of 1000 Hz. As ventricular pressures increased, such as in hypertension, chordae forces also increased. Overall, FBG sensors are a viable, durable, and high-fidelity sensing technology that can be effectively used to measure mitral valve chordae forces and overcome some limitations of other such technologies.

6 October 2020 in Circulation
Verified
Journal Article
Open access
PDF file
MPMichael J. Paulsen
Michael J. Paulsen
AIAnnabel Imbrie-Moore
Annabel Imbrie-Moore
MBMichael Baiocchi
Michael Baiocchi
HWHanjay Wang
Hanjay Wang
CHCamille E. Hironaka
Camille E. Hironaka
YWY. Joseph Woo
Y. Joseph Woo
Background: Many graft configurations are clinically used for valve-sparing aortic root replacement, some specifically focused on recapitulating neosinus geometry. However, the specific impact of such neosinuses on valvular and root biomechanics and the potential influence on long-term durability are unknown. Methods: Using a custom 3-dimenstional–printed heart simulator with porcine aortic roots (n=5), the anticommissural plication, Stanford modification, straight graft (SG), Uni-Graft, and Valsalva graft configurations were tested in series using an incomplete counterbalanced measures design, with the native root as a control, to mitigate ordering effects. Hemodynamic and videometric data were analyzed using linear models with conduit as the fixed effect of interest and valve as a fixed nuisance effect with post hoc pairwise testing using Tukey’s correction. Results: Hemodynamics were clinically similar between grafts and control aortic roots. Regurgitant fraction varied between grafts, with SG and Uni-Graft groups having the lowest regurgitant fractions and anticommissural plication having the highest. Root distensibility was significantly lower in SG versus both control roots and all other grafts aside from the Stanford modification ( P ≤0.01 for each). All grafts except SG had significantly higher cusp opening velocities versus native roots ( P <0.01 for each). Relative cusp opening forces were similar between SG, Uni-Graft, and control groups, whereas anticommissural plication, Stanford modification, and Valsalva grafts had significantly higher opening forces versus controls ( P 5-fold higher in the anticommissural plication, Stanford modification, and Valsalva graft groups. Conclusions: In this ex vivo modeling system, clinically used valve-sparing aortic root replacement conduit configurations have comparable hemodynamics but differ in biomechanical performance, with the straight graft most closely recapitulating native aortic root biomechanics.

23 July 2020 in Healthcare
Verified
Journal Article
Open access
PDF file
AIAnnabel Imbrie-Moore
Annabel Imbrie-Moore
MPMatthew Park
Matthew Park
YZYuanjia Zhu
Yuanjia Zhu
MPMichael Paulsen
Michael Paulsen
HWHanjay Wang
Hanjay Wang
YWY. Joseph Woo
Y. Joseph Woo
The need for personal protective equipment during the COVID-19 pandemic is far outstripping our ability to manufacture and distribute these supplies to hospitals. In particular, the medical N95 mask shortage is resulting in healthcare providers reusing masks or utilizing masks with filtration properties that do not meet medical N95 standards. We developed a solution for immediate use: a mask adaptor, outfitted with a quarter section of an N95 respirator that maintains the N95 seal standard, thereby quadrupling the N95 supply. A variety of designs were 3D-printed and optimized based on the following criteria: seal efficacy, filter surface area and N95 respirator multiplicity. The final design is reusable and features a 3D-printed soft silicone base as well as a rigid 3D-printed cartridge to seal one-quarter of a 3M 1860 N95 mask. Our mask passed the computerized N95 fit test for six individuals. All files are publicly available with this publication. Our design can provide immediate support for healthcare professionals in dire need of medical N95 masks by extending the current supply by a factor of four.