Since existing energy system models often represent storage behavior in a simplified way, in this work, a tool chain for deriving consistent storage model parameters for optimization models is developed. The aim of our research work is to identify what are non-negligible influences on the the technical characteristics and dynamic behavior of the storage, to quantify the effect of these influences, and represent these effects in the model. This paper describes the developed tool chain and presents its application using an example. The tool chain consists of the steps “parameter screening”, “dynamic simulation”, “regression analysis” and “refining optimization model”. It is investigated which parameters have an influence on the storage system (here pumped hydroelectric energy storage (PHES)), how the storage behavior is modeled, which influencing factors have a measurable effect on the system, and how these findings can be integrated into optimization models. The main finding is that in the case of PHES, the dependency of the charging and discharging efficiency on the power is significant, but no further influencing factor has to be considered for accurate modeling (0.946 ≤ R2 ≤ 0.988) of the efficiency. It is concluded that the presented toolchain is suitable for other storage technologies as well, including the analysis of aging behavior.
1 January 2024 in Entropie : Thermodynamique – Énergie – Environnement – Économie
Adiabatic compressed air energy storage (A-CAES) is a promising storage technology to face the challenges of high shares of renewable energies in an energy system by storing electric energy for (...)
Mathematical optimization is a widespread method in order to improve, for instance, the efficiency of energy systems. A simulation approach based on partial differential equations can typically not be formulated as an optimization problem, thus requiring interfacing to an external optimization environment. This is, among others, also true for the programming language Modelica. Because of high computation time, such coupled approaches are often limited to small-scale optimization problems. Since simulation models tend to get more complex, simulation time and, in turn, associated optimization time rise significantly. To enable proper sampling of the search space, individual optimization runs need to be solved in acceptable times. This paper addresses the search for a proper optimization approach and tool to couple with Modelica/Dymola. The optimization is carried out on an exemplary power plant model from the ClaRa-Library using an evolutionary algorithm (SPEA2-based) with Ansys optiSlang. To verify and evaluate the results, a comparison with the standard Dymola optimization library is performed. Both parallelization and indirect optimization with surrogate models achieved a significant runtime reduction by a factor of up to 5.4. The use of meta models is particularly advantageous for repetitive optimization runs of the same optimization problem but may lead to deviations due to the calculated approximations.