Elżbieta Mierzwińska-Nastalska

Dr. Elżbieta Mierzwińska-Nastalska


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 November 2020 in Polymers
Verified
Journal Article
Open access
PDF file
MCMariusz Cierech
Mariusz Cierech
Marcin SzerszeńMarcin Szerszeń
Marcin Szerszeń
Jacek WojnarowiczJacek Wojnarowicz
Jacek Wojnarowicz
Witold LojkowskiWitold Lojkowski
Witold Lojkowski
JKJolanta Kostrzewa-Janicka
Jolanta Kostrzewa-Janicka
EMElżbieta Mierzwińska-Nastalska
Elżbieta Mierzwińska-Nastalska
Introduction of titanium dioxide nanoparticles (TiO2 NPs) to poly(methyl methacrylate) (PMMA) aims to improve the mechanical, microbiological and tribological properties of dental prosthesis bases. The aim of the research was to assess the polymerisation time and the change in the colour of the new biomaterial. Samples with the 1 wt% and 2 wt% content of TiO2 additionally modified by ultrasounds were created. The effectiveness of ultrasounds was assessed by comparing the average size of conglomerates in a liquid acrylic resin monomer by means of a dynamic light scattering (DLS) analysis. The biomaterial structure was assessed by the energy-dispersive X-ray spectroscopy (EDS) analysis. The colour change was analysed by means of a colorimetric test and provided in the CIE (Commission internationale de l’éclairage) L*a*b* and RGB (Red Green Blue) colour palette. It was observed during the DLS test that the ultrasonic homogenisation process caused an increase in the suspension heterogeneity. The EDS analysis confirmed the presence of nanoparticles sized below 100 nm, which constitutes a ground for calling the new biomaterial a nanocomposite. The addition of TiO2 NPs as well as the ultrasounds result in the reduction of the average PMMA polymerisation time. The obtained data reveal that the addition of both 1 wt% and 2 wt% causes a considerable change in the PMMA colour: its whitening. To summarise, the reduced polymerisation time of the new biomaterial fully enables performance of standard procedures related to creation of dental prosthesis bases. Due to the considerable change in the colour, the clinical application is limited to performance of repairs or relining of the prosthesis, where the new material is located in an unaesthetic zone.

17 November 2022 in Polymers
Verified
Journal Article
Open access
PDF file
MCMariusz Cierech
Mariusz Cierech
MCMariusz Cierech
Mariusz Cierech
Jacek WojnarowiczJacek Wojnarowicz
Jacek Wojnarowicz
Bartłomiej GórskiBartłomiej Górski
Bartłomiej Górski
EMElżbieta Mierzwińska-Nastalska
Elżbieta Mierzwińska-Nastalska
(1) Background: The purpose of this in vitro study was to evaluate the color change and stability of a zinc oxide nanoparticle–poly(methyl methacrylate) (ZnO NP–PMMA) nanocomposite for denture base material after immersion in different dietary and cleaning agent solutions. (2) Methods: One hundred samples were prepared and divided into four equinumerous groups depending on the weight content of ZnO NPs. The color coordinates (CIE L*a*b*) were measured using a digital colorimeter, ColorReader (Datacolor AG Europe, Rotkreuz, Switzerland), before and after immersion of the specimens in five different solutions (distilled water, coffee, red wine, black tea, denture cleaning tablet solution) for 6 months. The color changes (ΔE) were calculated using Euclidean distance and analyzed by the Shapiro–Wilk test and the ANOVA/Kruskal–Wallis multiple comparison and adequate post hoc tests. (3) Results: All tested materials showed significant color changes after their exposure to all solutions. Color changes were greatest in the case of red wine and progressed with the duration of the study. (4) Conclusions: The modification of PMMA with ZnO nanoparticles is acceptable in aesthetic terms in 2.5% and 5% weight content; however, color changes are more noticeable with higher nanoparticle content and must be discussed with the patient prior to possible use.

30 June 2022 in Polymers
Verified
Journal Article
Open access
PDF file
ASAnastazja Skapska
Anastazja Skapska
ZKZenon Komorek
Zenon Komorek
MCMariusz Cierech
Mariusz Cierech
EMElżbieta Mierzwińska-Nastalska
Elżbieta Mierzwińska-Nastalska
(1) Background: Due to the limitations of composite cements, the authors carried out tests to compare such materials with preheated composite materials because the latter may be an alternative to cements in the adhesive cementation procedure. (2) Methods: The materials used in the adhesive cementation procedure, i.e., Enamel Plus Hri (Micerium, Avegno, Italy), a heated composite material, and RelyX U200 Automix (3M, Maplewood, MN, USA), a dual composite cement, were tested for microhardness, compressive strength, flexural strength, diametral compressive strength, and elastic modulus. Composite material was heated to the temperature of 50 degrees Celsius before polymerisation. (3) Results: Higher values of microhardness (by 67.36%), compressive strength (by 41.84%), elastic modulus (by 17.75%), flexural strength (by 36.03%), and diametral compressive strength (by 45.52%) were obtained using the Enamel Plus Hri composite material compared to the RelyX U200 self-adhesive cement. The survey results revealed statistically significant differences. (4) Conclusions: Due to its better mechanical properties, the heated composite material (Enamel Plus Hri) is a beneficial alternative to composite cements in the indirect restoration placement procedure. As the strength parameters of the heated composite material increase, a higher resistance to the compressive and bending forces present in the oral cavity, and hence a greater durability of the created prosthetic reconstructions can be expected.

8 April 2023 in Polymers
Verified
Journal Article
Open access
PDF file
Katarzyna Mańka-MalaraKatarzyna Mańka-Malara
Katarzyna Mańka-Malara
Marcin SzerszeńMarcin Szerszeń
Marcin Szerszeń
Bartłomiej GórskiBartłomiej Górski
Bartłomiej Górski
GTGen Tanabe
Gen Tanabe
TUToshiaki Ueno
Toshiaki Ueno
EMElżbieta Mierzwińska-Nastalska
Elżbieta Mierzwińska-Nastalska
This in vitro study aimed to evaluate the hardness and color change of an ethylene-vinyl-acetate copolymer (EVA) material for mouthguards after exposition to different cleaning agent solutions and isotonic drinks. Four hundred samples were prepared and divided into four equinumerous groups (n = 100), in which there were 25 samples from each color of EVA (red, green, blue and white). The hardness, using the digital durometer, and the color coordinates (CIE L*a*b*), using the digital colorimeter, were measured before the first exposition and after 3 months of exposition to spray disinfection and incubation in the oral cavity temperature, or immersion in isotonic drinks. The values of Shore A hardness (HA) and color change (ΔE—calculated by Euclidean distance) were statistically analyzed using the Kolmogorov–Smirnov test, multiple comparison ANOVA/Kruskal–Wallis and appropriate post-hoc tests. Statistically significant changes in color and hardness between the tested groups were demonstrated after the use of agents predestined for disinfecting the surface of mouthguards on the tested samples. There were no statistically significant differences in color and hardness between the groups immersed in isotonic sport drinks potentially consumed by competitors practicing combat sports using mouthguards. Despite the changes in color and hardness after the use of disinfectants, the deviations were minor and limited to specific colors of the EVA plates. The intake of isotonic drinks practically did not change either the color or the hardness of the samples, regardless of the tested color of the EVA plates.

8 December 2022 in Polymers
Verified
Journal Article
Open access
PDF file
Katarzyna Mańka-MalaraKatarzyna Mańka-Malara
Katarzyna Mańka-Malara
MTMaciej Trzaskowski
Maciej Trzaskowski
EMElżbieta Mierzwińska-Nastalska
Elżbieta Mierzwińska-Nastalska
Ethylene vinyl acetate mouthguards are the most often used custom protective intraoral appliances by combat sports practitioners. However, due to the difficulties in maintaining the hygiene of such mouthguards and thinning during fabrication, resulting in difficulty in predicting final dimensions, they may not be the optimal solution. The aim of this research was to evaluate an innovative method of mouthguard formation using intraoral modeling of the mouthguard pattern, hybrid acrylic material, and the addition of ZnO nanoparticles. Seventeen mouthguards patterns and 34 custom mouthguards were evaluated: 17 hybrid and 17 nanohybrid. A total of 1122 measurements were performed: each mouthguard and pattern was measured at 22 points. Statistical analyses were performed with the use of IBM® SPSS® Statistics 27.0.0 software (IBM, Armonk, NY USA). The mean thickness of the patterns and mouthguards at all labial areas of central incisors were between 4.65 and 4.80 mm. The thickness at the buccal surface of the first molar was between 3.71 and 4 mm, and at the occlusal surface between 3.40 and 3.56 mm in the cusp area. All measurements of hybrid and nanohybrid mouthguards were strongly and highly correlated with the measurements of the mouthguard patterns. Hybrid and nanohybrid mouthguards are an advantageous alternative to thermoformed custom appliances.

7 January 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
EWElżbieta Wojtyńska
Elżbieta Wojtyńska
BBBohdan Bączkowski
Bohdan Bączkowski
MCMariusz Cierech
Mariusz Cierech
EMElżbieta Mierzwińska-Nastalska
Elżbieta Mierzwińska-Nastalska
Background: Prosthetic rehabilitation for children and juvenile patients with congenital or acquired craniofacial disorders is the area of activity of many clinicians and is a major diagnostic and therapeutic challenge for dentists. Methods: Studies were carried out on a group of 30 patients (10 female and 20 male) aged 2.5 to 30 years who were treated prosthetically due to congenital and acquired craniofacial disorders. The aim of this study was to assess the quality of life using the CPQ 11-14 (Child Perception Questionnaire 11-14), OQLQ (Orthognathic Quality of Life Questionnaire), and PIDAQ (Psychosocial Impact of Dental Aesthetics Questionnaire). Results: Before the prosthetic treatments, the mean values in the individual questionnaires were, respectively, CPQ 11-14—54 points; OQLQ—44.4 points; and PIDAQ—47.6 points. The following values were obtained after the treatments: CPQ 11-14—12.43 points; OQLQ—22.27 points; and PIDAQ—34.03 points. All obtained differences were statistically significant. Conclusions: The total numerical results obtained in all questionnaires decreased, which means that prosthetic rehabilitation had a positive impact on the assessment of the quality of life based on individual categories.