Yuhua Jiang

Yuhua Jiang


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 June 2019 in European Radiology
Verified
Journal Article
Closed access
PDF file
XLXinke Liu
Xinke Liu
ZZZihao Zhang
Zihao Zhang
CZChengcheng Zhu
Chengcheng Zhu
JFJunqiang Feng
Junqiang Feng
PLPeng Liu
Peng Liu
YLYouxiang Li
Youxiang Li

21 February 2019 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
HQHaikun Qi
Haikun Qi
XLX. Liu
X. Liu
PLP. Liu
P. Liu
WYW. Yuan
W. Yuan
ALAihua Liu
Aihua Liu
HCHuijun Chen
Huijun Chen
BACKGROUND AND PURPOSE: Individual assessment of the absolute risk of intracranial aneurysm rupture remains challenging. Emerging imaging techniques such as dynamic contrast-enhanced MR imaging and postcontrast vessel wall MR imaging may improve risk estimation by providing new information on aneurysm wall properties. The purpose of this study was to investigate the relationship between aneurysm wall permeability on dynamic contrast-enhanced MR imaging and aneurysm wall enhancement on postcontrast vessel wall MR imaging in unruptured intracranial aneurysms. MATERIALS AND METHODS: Patients with unruptured saccular intracranial aneurysms were imaged with vessel wall MR imaging before and after gadolinium contrast administration. Dynamic contrast-enhanced MR imaging was performed coincident with contrast injection using 3D T1-weighted spoiled gradient-echo imaging. The transfer constant (Ktrans) was measured adjacent to intracranial aneurysm and adjacent to the normal intracranial artery. RESULTS: Twenty-nine subjects were analyzed (mean age, 53.9 ± 13.5 years; 24% men; PHASES score: median, 8; interquartile range, 4.75–10). Ktrans was higher in intracranial aneurysms compared with the normal intracranial artery (median, 0.0110; interquartile range, 0.0060–0.0390 versus median, 0.0032; interquartile range, 0.0018–0.0048 min−1; P < .001), which correlated with intracranial aneurysm size (Spearman ρ = 0.54, P = .002) and PHASES score (ρ = 0.40, P = .30). Aneurysm wall enhancement, detected in 19 (66%) aneurysms, was associated with intracranial aneurysm size and the PHASES score but not significantly with Ktrans (P = .30). Aneurysms of 2 of the 9 patients undergoing conservative treatment ruptured during 1-year follow-up. Both ruptured aneurysms had increased Ktrans, whereas only 1 had aneurysm wall enhancement at baseline. CONCLUSIONS: Dynamic contrast-enhanced MR imaging showed increased Ktrans adjacent to intracranial aneurysms, which was independent of aneurysm wall enhancement on postcontrast vessel wall MR imaging. Increased aneurysm wall permeability on dynamic contrast-enhanced MR imaging provides new information that may be useful in intracranial aneurysm risk assessment.

27 October 2018 in Journal of Medical and Biological Engineering
Verified
Journal Article
Closed access
PDF file
YWYuan Wang
Yuan Wang
SGShuoxin Gu
Shuoxin Gu
NXNan Xiao
Nan Xiao
YLYouxiang Li
Youxiang Li
YJYuhua Jiang
Yuhua Jiang

16 April 2018 in Applied Bionics and Biomechanics
Verified
Journal Article
Open access
PDF file
YJYuhua Jiang
Yuhua Jiang
KLKeyun Liu
Keyun Liu
YLYouxiang Li
Youxiang Li
To evaluate the feasibility and safety of the robot of endovascular treatment (RobEnt) in clinical practice, we carried out a cerebral angiography using this robot system. We evaluated the performance of application of the robot system to clinical practice through using this robotic system to perform the digital subtraction angiography for a patient who was suspected of suffering intracranial aneurysm. At the same time, through comparing the postoperative head nuclear magnetic and blood routine with the preoperative examination, we evaluated the safety of application of the robot system to clinical practice. We performed the robot system to complete the bilateral carotid artery and bilateral vertebral arteriography. The results indicate that there was no obvious abnormality in the patient’s cerebral artery. No obvious abnormality was observed in the examination of patients’ check-up, head nuclear magnetism, and blood routine after the digital subtraction angiography. From this clinical trial, it can be observed that the robot system can perform the operation of cerebral angiography. The robot system can basically complete the related observation indexes, and its accuracy, effectiveness, stability, and safety basically meet the requirements of clinical application in neurointerventional surgery.

16 November 2024 in Metabolic Brain Disease
Verified
Journal Article
Closed access
PDF file
SGSiming Gui
Siming Gui
JJJia Jiang
Jia Jiang
DDDingwei Deng
Dingwei Deng
DWDachao Wei
Dachao Wei
XCXiheng Chen
Xiheng Chen
YLYouxiang Li
Youxiang Li

28 January 2021 in Applied Bionics and Biomechanics
Verified
Journal Article
Open access
PDF file
KLKeyun Liu
Keyun Liu
YJYuhua Jiang
Yuhua Jiang
YLYouxiang Li
Youxiang Li
In order to inspect and improve the system performance of the neuro-interventional surgical robot and its effectiveness and safety in clinical applications, we conducted ten animal experiments using this robotic system. Cerebral angiography was performed on ten experimental animals, and various mechanical performance indicators, operating time, X-ray radiation dosage to the experimental animals and the experimenter, and arterial damage in the experimental animals were recorded when the robotic system completed cerebral angiography. The results show that the robotic system can successfully complete the cerebral angiography surgery, and the mechanical performance is up to standard. The operating time is almost the same as the physician’s operating time. And the mean X-ray radiation dosage received by the experimental animals and experimenter was 0.893 Gy and 0.0859 mSv, respectively. There were no complications associated with damage to the vascular endothelium. The robotic system can basically complete the relevant assessment indicators, and its system performance, effectiveness, and safety in clinical applications meet the standards, basically meeting the requirements of clinical applications of neurointerventional surgery.