The rising cost and demand for energy have prompted the need to devise innovative methods for energy monitoring, control, and conservation. In addition, statistics show that 20% of energy losses are due to the mismanagement of energy. Therefore, the utilization of energy management can make a substantial contribution to reducing the unnecessary usage of energy consumption. In line with that, the intelligent control and optimization of energy management systems integrated with renewable energy resources and energy storage systems are required to increase building energy efficiency while considering the reduction in the cost of energy bills, dependability of the grid, and mitigating carbon emissions. Even though a variety of optimization and control tactics are being utilized to reduce energy consumption in buildings nowadays, several issues remain unsolved. Therefore, this paper presents a critical review of energy management in commercial buildings and a comparative discussion to improve building energy efficiency using both active and passive solutions, which could lead to net-zero energy buildings. This work also explores different optimum energy management controller objectives and constraints concerning user comfort, energy policy, data privacy, and security. In addition, the review depicts prospective future trends and issues for developing an effective building energy management system, which may play an unavoidable part in fulfilling the United Nations Sustainable Development Goals.

1 January 2013 in Turkish Journal of Electrical Engineering and Computer Sciences
Verified
Journal Article
Closed access
AKA. F.A Kadir
A. F.A Kadir
AMAzah Mohamed
Azah Mohamed
HSHussain Shareef
Hussain Shareef
MWMohd Zamri Che Wanik
Mohd Zamri Che Wanik

4 July 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
JHJahangir Hossain
Jahangir Hossain
AKA. F.A Kadir
A. F.A Kadir
HSHussain Shareef
Hussain Shareef
RMRampelli Manojkumar
Rampelli Manojkumar
Nagham SaeedNagham Saeed
Nagham Saeed
AHAinain Nur Hanafi
Ainain Nur Hanafi
In this article, the optimal sizing of hybrid solar photovoltaic and battery energy storage systems is evaluated with respect to rooftop space and feed-in tariff rates. The battery scheduling is performed using a proposed rule-based energy management strategy. The rules are formulated based on the demand limit, PV export power limit, and state of charge of the battery. Furthermore, optimization modeling with initial choices of parameters and constraints in terms of solar photovoltaic and battery energy storage capabilities is developed to minimize the total net present cost. The hourly values of solar irradiance, air temperature, electrical loads, and electricity rates are considered the inputs of the optimization process. The optimization results are achieved using particle swarm optimization and validated through an uncertainty analysis. It is observed that an optimal photovoltaic and battery energy storage system can reduce the cost of electricity by 12.33%, including the sale of 5944.029 kWh of electricity to the grid. Furthermore, energy consumption, peak demand, and greenhouse gas emissions are reduced by 13.71%, 5.85%, and 62.59%, respectively. A comprehensive analysis between the variable and fixed data for the load, energy from PV, batteries, and the grid, and costs demonstrates that the optimal sizing of photovoltaic and battery energy storage systems with the best mix of energy from PV, batteries, and the grid provides the optimal solution for the proposed configuration.

1 May 2014 in Journal of Renewable and Sustainable Energy
Verified
Journal Article
Closed access
PDF file
AKA. F.A Kadir
A. F.A Kadir
AMAzah Mohamed
Azah Mohamed
HSHussain Shareef
Hussain Shareef
Ahmad Asrul IbrahimAhmad Asrul Ibrahim
Ahmad Asrul Ibrahim
TKTamer Khatib
Tamer Khatib
WEWilfried Elmenreich
Wilfried Elmenreich
Distributed generation (DG) is an important element to be considered in distribution planning since it plays a major role in stability and power quality improvement. This paper presents a new method for determining optimal sizing and placement of DG in a distribution system. A multi-objective function is formed to minimize the total losses, average total voltage harmonic distortion, and voltage deviation in the distribution system. The improved gravitational search algorithm (IGSA) is proposed as an optimization techniques and its performance is compared with other optimization techniques such as particle swarm optimization (PSO) and GSA. The load flow algorithm from MATPOWER and harmonic load flow was integrated in MATLAB environment to solve the proposed multi-objective function. Finally, the proposed algorithm is tested on the radial 69-bus distribution system with three case studies. The results show that the IGSA performs better than PSO and GSA by giving the best fitness value and the fastest average elapsed time.

1 May 2011
Verified
Conference Paper
Closed access
AKA. F.A Kadir
A. F.A Kadir
AMA. Mohamed
A. Mohamed
HSH. Shareef
H. Shareef
This paper is concerned with harmonic impact of different types of distributed generation (DG) units in low voltage distribution systems. This study considers the impact of three types of DG units connected to a power system, a mini hydro synchronous generator, photovoltaic system and double fed induction generator wind turbine. The DG units are modelled using the PSCAD/EMTDC program and simulations are carried out by installing the DG units on the 2 bus and 13 bus distribution systems. The results showed that the voltage total (THDV) harmonic distortion produced in the system depends on factors such as type of DG, its interfaces with the utility system, the number of DG unit and the location of the DG installed in the system. The results also showed that the THDV exceed its harmonic limit of 5% when four DG units of wind turbine type are installed in the distribution system.

16 May 2018 in Applied Sciences
Verified
Journal Article
Open access
PDF file
NNNur Faziera Napis
Nur Faziera Napis
AKA. F.A Kadir
A. F.A Kadir
TKTamer Khatib
Tamer Khatib
EHElia Erwani Hassan
Elia Erwani Hassan
MSMohamad Fani Sulaima
Mohamad Fani Sulaima
The presence of optimized distributed generation (DG) with suitable distribution network reconfiguration (DNR) in the electrical distribution network has an advantage for voltage support, power losses reduction, deferment of new transmission line and distribution structure and system stability improvement. However, installation of a DG unit at non-optimal size with non-optimal DNR may lead to higher power losses, power quality problem, voltage instability and incremental of operational cost. Thus, an appropriate DG and DNR planning are essential and are considered as an objective of this research. An effective heuristic optimization technique named as improved evolutionary particle swarm optimization (IEPSO) is proposed in this research. The objective function is formulated to minimize the total power losses (TPL) and to improve the voltage stability index (VSI). The voltage stability index is determined for three load demand levels namely light load, nominal load, and heavy load with proper optimal DNR and DG sizing. The performance of the proposed technique is compared with other optimization techniques, namely particle swarm optimization (PSO) and iteration particle swarm optimization (IPSO). Four case studies on IEEE 33-bus and IEEE 69-bus distribution systems have been conducted to validate the effectiveness of the proposed IEPSO. The optimization results show that, the best achievement is done by IEPSO technique with power losses reduction up to 79.26%, and 58.41% improvement in the voltage stability index. Moreover, IEPSO has the fastest computational time for all load conditions as compared to other algorithms.