Lorenzo Arsini

Dr. Lorenzo Arsini

CREF
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 January 2021 in Nutrients
Verified
Journal Article
Open access
PDF file
Laura Di RenzoLaura Di Renzo
Laura Di Renzo
GCGiulia Cinelli
Giulia Cinelli
LRLorenzo Romano
Lorenzo Romano
SZSamanta Zomparelli
Samanta Zomparelli
GSGemma Lou De Santis
Gemma Lou De Santis
ALAntonino De Lorenzo
Antonino De Lorenzo
Lipoedema is a subcutaneous adipose tissue disease characterized by the increase in the amount and structure of fat mass (FM) in specific areas, causing pain and discomfort. 95% of patients fail to lose weight in the lipoedema areas. The study was conducted to evaluate body composition and general health status modification in a group of lipoedema patients (LIPPY) and a control group (CTRL) after four weeks of a modified Mediterranean diet therapy (mMeD). A total of 29 subjects were included in the data analysis, divided in two groups: 14 LIPPY and 15 CTRL. After the mMeD, both groups significantly decreased their weight and body mass index; the CTRL also showed a reduction of all the circumferences and all FM’s compartments. LIPPY showed a decrease of FM in upper and lower limbs. No significant differences in Δ% between the groups were observed for the lean mass (LM). In LIPPY, an increase in the patients’ ability to perform various daily physical activities related to the loss of arms’ and legs’ fat was observed. According to the European Quality of Life scale, the possibility for LIPPY subjects to perform simple daily activities with less fatigue, pain and anxiety is highlighted. Further long-term studies are recommended to confirm the mMeD as a good strategy for Lipoedema treatment.

21 February 2025 in Medical Physics
Verified
Journal Article
Open access
PAPedro Arce
Pedro Arce
JAJay W. Archer
Jay W. Archer
LALorenzo Arsini
Lorenzo Arsini
ABAlexander Bagulya
Alexander Bagulya
DBDavid Bolst
David Bolst
DWDennis H. Wright
Dennis H. Wright
Background: Geant4, a Monte Carlo Simulation Toolkit extensively used in bio‐medical physics, is in continuous evolution to include newest research findings to improve its accuracy and to respond to the evolving needs of a very diverse user community. In 2014, the G4‐Med benchmarking system was born from the effort of the Geant4 Medical Simulation Benchmarking Group, to benchmark and monitor the evolution of Geant4 for medical physics applications. The G4‐Med system was first described in our Medical Physics Special Report published in 2021. Results of the tests were reported for Geant4 10.5. Purpose: In this work, we describe the evolution of the G4‐Med benchmarking system. Methods: The G4‐Med benchmarking suite currently includes 23 tests, which benchmark Geant4 from the calculation of basic physical quantities to the simulation of more clinically relevant set‐ups. New tests concern the benchmarking of Geant4‐DNA physics and chemistry components for regression testing purposes, dosimetry for brachytherapy with a source, dosimetry for external x‐ray and electron FLASH radiotherapy, experimental microdosimetry for proton therapy, and in vivo PET for carbon and oxygen beams. Regression testing has been performed between Geant4 10.5 and 11.1. Finally, a simple Geant4 simulation has been developed and used to compare Geant4 EM physics constructors and physics lists in terms of execution times. Results: In summary, our EM tests show that the parameters of the multiple scattering in the Geant4 EM constructor G4EmStandardPhysics_option3 in Geant4 11.1, while improving the modeling of the electron backscattering in high atomic number targets, are not adequate for dosimetry for clinical x‐ray and electron beams. Therefore, these parameters have been reverted back to those of Geant4 10.5 in Geant4 11.2.1. The x‐ray radiotherapy test shows significant differences in the modeling of the bremsstrahlung process, especially between G4EmPenelopePhysics and the other constructors under study ( G4EmLivermorePhysics , G4EmStandardPhysics_option3 , and G4EmStandardPhysics_option4 ). These differences will be studied in an in‐depth investigation within our Group. Improvement in Geant4 11.1 has been observed for the modeling of the proton and carbon ion Bragg peak with energies of clinical interest, thanks to the adoption of ICRU90 to calculate the low energy proton stopping powers in water and of the Linhard–Sorensen ion model, available in Geant4 since version 11.0. Nuclear fragmentation tests of interest for carbon ion therapy show differences between Geant4 10.5 and 11.1 in terms of fragment yields. In particular, a higher production of boron fragments is observed with Geant4 11.1, leading to a better agreement with reference data for this fragment. Conclusions: Based on the overall results of our tests, we recommend to use G4EmStandardPhysics_option4 as EM constructor and QGSP_BIC_HP with G4EmStandardPhysics_option4 , for hadrontherapy applications. The Geant4‐DNA physics lists report differences in modeling electron interactions in water, however, the tests have a pure regression testing purpose so no recommendation can be formulated.

6 March 2023 in Algorithms
Verified
Journal Article
Open access
PDF file
LALorenzo Arsini
Lorenzo Arsini
BCBarbara Caccia
Barbara Caccia
ACAndrea Ciardiello
Andrea Ciardiello
Stefano GiaguStefano Giagu
Stefano Giagu
CMCarlo Mancini-Terracciano
Carlo Mancini-Terracciano
Graphs are versatile structures for the representation of many real-world data. Deep Learning on graphs is currently able to solve a wide range of problems with excellent results. However, both the generation of graphs and the handling of large graphs still remain open challenges. This work aims to introduce techniques for generating large graphs and test the approach on a complex problem such as the calculation of dose distribution in oncological radiotherapy applications. To this end, we introduced a pooling technique (ReNN-Pool) capable of sampling nodes that are spatially uniform without computational requirements in both model training and inference. By construction, the ReNN-Pool also allows the definition of a symmetric un-pooling operation to recover the original dimensionality of the graphs. We also present a Variational AutoEncoder (VAE) for generating graphs, based on the defined pooling and un-pooling operations, which employs convolutional graph layers in both encoding and decoding phases. The performance of the model was tested on both the realistic use case of a cylindrical graph dataset for a radiotherapy application and the standard benchmark dataset sprite. Compared to other graph pooling techniques, ReNN-Pool proved to improve both performance and computational requirements.

1 July 2025 in Physica Medica
Verified
Journal Article
Open access
LALorenzo Arsini
Lorenzo Arsini
JHJack Humphreys
Jack Humphreys
CWChristopher White
Christopher White
FMFlorian Mentzel
Florian Mentzel
JPJason Paino
Jason Paino
CTCarlo Mancini Terracciano
Carlo Mancini Terracciano
Microbeam Radiation Therapy (MRT) is an innovative radiotherapy modality which uses highly focused synchrotron-generated X-ray microbeams. Current pre-clinical research in MRT mostly rely on Monte Carlo (MC) simulations for dose estimation, which are highly accurate but computationally intensive. Recently, Deep Learning (DL) dose engines have been proved effective in generating fast and reliable dose distributions in different RT modalities. However, relatively few studies compare different models on the same task. This work aims to compare a Graph-Convolutional-Network-based DL model, developed in the context of Very High Energy Electron RT, to the Convolutional 3D U-Net that we recently implemented for MRT dose predictions. The two DL solutions are trained with 3D dose maps, generated with the MC-Toolkit Geant4, in rats used in MRT pre-clinical research. The models are evaluated against Geant4 simulations, used as ground truth, and are assessed in terms of Mean Absolute Error, Mean Relative Error, and a voxel-wise version of the γ-index. Also presented are specific comparisons of predictions in relevant tumor regions, tissues boundaries and air pockets. The two models are finally compared from the perspective of the execution time and size. This study finds that the two models achieve comparable overall performance. Main differences are found in their dosimetric accuracy within specific regions, such as air pockets, and their respective inference times. Consequently, the choice between models should be guided primarily by data structure and time constraints, favoring the graph-based method for its flexibility or the 3D U-Net for its faster execution.

5 June 2025 in Physica Medica
Verified
Journal Article
Closed access
FNFrancesca Nicolanti
Francesca Nicolanti
LALorenzo Arsini
Lorenzo Arsini
LCL. Campana
L. Campana
FCF. Collamati
F. Collamati
RFR. Faccini
R. Faccini
CTC.MAncini Terracciano
C.MAncini Terracciano

21 October 2025 in Physica Medica
Verified
Journal Article
Open access
JHJack Humphreys
Jack Humphreys
CWChristopher White
Christopher White
FMFlorian Mentzel
Florian Mentzel
DBDavid Bolst
David Bolst
JPJason Paino
Jason Paino
MHMarkus Hagenbuchner
Markus Hagenbuchner
Microbeam Radiation Therapy (MRT) is an emerging radiotherapy technique which is currently at the research stage. In order to further progress from research, toward clinical deployment, it is essential to develop a reliable and accurate dose engine such as Monte Carlo (MC) simulations. MC execution times are far too long for practical, clinical applications. In previous studies, we used a 3D U-Net, trained with Geant4 MC simulations, to calculate the dose in digital rat phantoms. This choice of model imposes significant scalability challenges in the case of larger geometries. Casting MRT dose prediction as a 3D point cloud regression problem is a flexible and extensible solution to overcoming many of these hurdles. This problem formulation requires the use of point-based models which are unproven for the task of MRT dose prediction. In order to assay the viability of this family of models on this task, the SphereFormer is trained to accurately replicate the gold standard MC dosimetry on uniform voxel grids. Furthermore, the benefits of the scalability of this method are demonstrated by the utilisation of out-of-field information to significantly improve over the existing state-of-the-art results on valley dose prediction, being accurate to within 3% for at least 84.1% of voxels compared with 78.2% for the baseline. This paper serves as a proof-of-concept study for the application of 3D point cloud methods to MRT dose prediction and marks the first time such a method have been applied to dosimetry in general.