Alexander V. Bagulya

Alexander V. Bagulya

Auto-generated profile, based on publicly available information

Alexander V. Bagulya

Lebedev Physical Institute, Moscow, Russian Federation

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 February 2025 in Medical Physics
Verified
Journal Article
Open access
PAPedro Arce
Pedro Arce
JAJay W. Archer
Jay W. Archer
LALorenzo Arsini
Lorenzo Arsini
ABAlexander Bagulya
Alexander Bagulya
DBDavid Bolst
David Bolst
DWDennis H. Wright
Dennis H. Wright
Background: Geant4, a Monte Carlo Simulation Toolkit extensively used in bio‐medical physics, is in continuous evolution to include newest research findings to improve its accuracy and to respond to the evolving needs of a very diverse user community. In 2014, the G4‐Med benchmarking system was born from the effort of the Geant4 Medical Simulation Benchmarking Group, to benchmark and monitor the evolution of Geant4 for medical physics applications. The G4‐Med system was first described in our Medical Physics Special Report published in 2021. Results of the tests were reported for Geant4 10.5. Purpose: In this work, we describe the evolution of the G4‐Med benchmarking system. Methods: The G4‐Med benchmarking suite currently includes 23 tests, which benchmark Geant4 from the calculation of basic physical quantities to the simulation of more clinically relevant set‐ups. New tests concern the benchmarking of Geant4‐DNA physics and chemistry components for regression testing purposes, dosimetry for brachytherapy with a source, dosimetry for external x‐ray and electron FLASH radiotherapy, experimental microdosimetry for proton therapy, and in vivo PET for carbon and oxygen beams. Regression testing has been performed between Geant4 10.5 and 11.1. Finally, a simple Geant4 simulation has been developed and used to compare Geant4 EM physics constructors and physics lists in terms of execution times. Results: In summary, our EM tests show that the parameters of the multiple scattering in the Geant4 EM constructor G4EmStandardPhysics_option3 in Geant4 11.1, while improving the modeling of the electron backscattering in high atomic number targets, are not adequate for dosimetry for clinical x‐ray and electron beams. Therefore, these parameters have been reverted back to those of Geant4 10.5 in Geant4 11.2.1. The x‐ray radiotherapy test shows significant differences in the modeling of the bremsstrahlung process, especially between G4EmPenelopePhysics and the other constructors under study ( G4EmLivermorePhysics , G4EmStandardPhysics_option3 , and G4EmStandardPhysics_option4 ). These differences will be studied in an in‐depth investigation within our Group. Improvement in Geant4 11.1 has been observed for the modeling of the proton and carbon ion Bragg peak with energies of clinical interest, thanks to the adoption of ICRU90 to calculate the low energy proton stopping powers in water and of the Linhard–Sorensen ion model, available in Geant4 since version 11.0. Nuclear fragmentation tests of interest for carbon ion therapy show differences between Geant4 10.5 and 11.1 in terms of fragment yields. In particular, a higher production of boron fragments is observed with Geant4 11.1, leading to a better agreement with reference data for this fragment. Conclusions: Based on the overall results of our tests, we recommend to use G4EmStandardPhysics_option4 as EM constructor and QGSP_BIC_HP with G4EmStandardPhysics_option4 , for hadrontherapy applications. The Geant4‐DNA physics lists report differences in modeling electron interactions in water, however, the tests have a pure regression testing purpose so no recommendation can be formulated.

17 May 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AAAskerkhan Abiev
Askerkhan Abiev
ABAlexander Bagulya
Alexander Bagulya
MCMikhail Chernyavskiy
Mikhail Chernyavskiy
ADAigerim Dashkina
Aigerim Dashkina
ADAlexey Dimitrienko
Alexey Dimitrienko
PZPavel Zarubin
Pavel Zarubin
The paper presents the test experiment to investigate one of UNESCO’s (United Nations Educational, Scientific and Cultural Organization) world heritage objects, an archaeological site in the Naryn-Kala citadel (Derbent, Republic of Dagestan, Russian Federation) hidden under the ground’s surface. The function of the site could be revealed by the muon radiography studies. Several nuclear emulsion detectors were exposed for two months inside the site at a depth about 10 m from the modern surface. The use of nuclear emulsions as probing radiation detectors combined with the potential of modern image analysis methods provides for a uniquely high resolution capacity of recording instrumentation and 3D reconstruction of the internal structure of the investigated object. Here we present the experiment and data analysis details and the first results.

1 April 2023 in Bulletin of the Lebedev Physics Institute
Verified
Journal Article
Closed access
PDF file
ABA. V. Bagulya
A. V. Bagulya
VGV. M. Grichine
V. M. Grichine
IZI. N. Zavestovskaya
I. N. Zavestovskaya
VRV. A. Ryabov
V. A. Ryabov
In order to increase the absorbed dose around the Bragg peak region, it is proposed to use the p+11B → 3α reaction for proton therapy. This reac

1 August 2024 in Bulletin of the Lebedev Physics Institute
Verified
Journal Article
Closed access
PDF file
ABA. V. Bagulya
A. V. Bagulya
VGV. M. Grichine
V. M. Grichine
VRV. A. Ryabov
V. A. Ryabov
IZI. N. Zavestovskaya
I. N. Zavestovskaya
Bragg curves for protons, alpha-particles, and carbon ions in water are calculated using the Geant4 software package. The calculation results, whi

1 September 2024 in JETP Letters
Verified
Journal Article
Closed access
PDF file
ABA. V. Bagulya
A. V. Bagulya
VGV. M. Grishin
V. M. Grishin
IZI. N. Zavestovskaya
I. N. Zavestovskaya
VRV. A. Ryabov
V. A. Ryabov
The spectrum of inelastic collisions of low-energy protons in the field of molecular excitations of water is obtained in terms of the complex refractive index of water determined from optical measurements in the infrared, visible, and ultraviolet regions. In the range of atomic frequencies (energies), the inelastic collision spectrum is determined from the integrated absorption cross section of X and gamma rays. The resulting spectra will extend the range of applicability of the photoionization model, which is of interest for improving dosimetry planning of the exposure of patients in proton (ion) therapy.

1 November 2024 in Bulletin of the Lebedev Physics Institute
Verified
Journal Article
Closed access
PDF file
ABA. V. Bagulya
A. V. Bagulya
VGV. M. Grichine
V. M. Grichine
VIV. N. Ivanchenko
V. N. Ivanchenko
VRV. A. Ryabov
V. A. Ryabov
SFS. N. Filimonov
S. N. Filimonov
The Geant4 software package is used to calculate hadronic and electromagnetic inelastic cross sections of interactions of relativistic heavy nuclei as func