Functional assessment of in vitro neuronal networks—of relevance for disease modelling and drug testing—can be performed using multi-electrode array (MEA) technology. However, the handling and processing of the large amount of data typically generated in MEA experiments remains a huge hurdle for researchers. Various software packages have been developed to tackle this issue, but to date, most are either not accessible through the links provided by the authors or only tackle parts of the analysis. Here, we present ‘‘MEA-ToolBox’’, a free open-source general MEA analytical toolbox that uses a variety of literature-based algorithms to process the data, detect spikes from raw recordings, and extract information at both the single-channel and array-wide network level. MEA-ToolBox extracts information about spike trains, burst-related analysis and connectivity metrics without the need of manual intervention. MEA-ToolBox is tailored for comparing different sets of measurements and will analyze data from multiple recorded files placed in the same folder sequentially, thus considerably streamlining the analysis pipeline. MEA-ToolBox is available with a graphic user interface (GUI) thus eliminating the need for any coding expertise while offering functionality to inspect, explore and post-process the data. As proof-of-concept, MEA-ToolBox was tested on earlier-published MEA recordings from neuronal networks derived from human induced pluripotent stem cells (hiPSCs) obtained from healthy subjects and patients with neurodevelopmental disorders. Neuronal networks derived from patient’s hiPSCs showed a clear phenotype compared to those from healthy subjects, demonstrating that the toolbox could extract useful parameters and assess differences between normal and diseased profiles.
Continuous monitoring of tissue microphysiology is a key enabling feature of the organ-on-chip (OoC) approach for in vitro drug screening and disease modeling. Integrated sensing units are particularly convenient for microenvironmental monitoring. However, sensitive in vitro and real-time measurements are challenging due to the inherently small size of OoC devices, the characteristics of commonly used materials, and external hardware setups required to support the sensing units. Here we propose a silicon-polymer hybrid OoC device that encompasses transparency and biocompatibility of polymers at the sensing area, and has the inherently superior electrical characteristics and ability to house active electronics of silicon. This multi-modal device includes two sensing units. The first unit consists of a floating-gate field-effect transistor (FG-FET), which is used to monitor changes in pH in the sensing area. The threshold voltage of the FG-FET is regulated by a capacitively-coupled gate and by the changes in charge concentration in close proximity to the extension of the floating gate, which functions as the sensing electrode. The second unit uses the extension of the FG as microelectrode, in order to monitor the action potential of electrically active cells. The layout of the chip and its packaging are compatible with multi-electrode array measurement setups, which are commonly used in electrophysiology labs. The multi-functional sensing is demonstrated by monitoring the growth of induced pluripotent stem cell-derived cortical neurons. Our multi-modal sensor is a milestone in combined monitoring of different, physiologically-relevant parameters on the same device for future OoC platforms.
Organ-on-a-chip (OoC) and microfluidic devices are conventionally produced using microfabrication procedures that require cleanrooms, silicon wafers, and photomasks. The prototyping stage often requires multiple iterations of design steps. A simplified prototyping process could therefore offer major advantages. Here, we describe a rapid and cleanroom-free microfabrication method using maskless photolithography. The approach utilizes a commercial digital micromirror device (DMD)-based setup using 375 nm UV light for backside exposure of an epoxy-based negative photoresist (SU-8) on glass coverslips. We show that microstructures of various geometries and dimensions, microgrooves, and microchannels of different heights can be fabricated. New SU-8 molds and soft lithography-based polydimethylsiloxane (PDMS) chips can thus be produced within hours. We further show that backside UV exposure and grayscale photolithography allow structures of different heights or structures with height gradients to be developed using a single-step fabrication process. Using this approach: (1) digital photomasks can be designed, projected, and quickly adjusted if needed; and (2) SU-8 molds can be fabricated without cleanroom availability, which in turn (3) reduces microfabrication time and costs and (4) expedites prototyping of new OoC devices.
A growing societal awareness is calling upon scientists to reconsider the use of animals in research, which stimulates the development of translational in vitro models. The physiological and architectural interactions between different cell types within an organ present a challenge to these models, particularly for a complex organ such as the brain. Thus far, in vitro brain models mostly consist of a single cell type and demonstrate little predictive value. Here, we present a co-culture of an epileptic human neocortical biopsy on a layer of human induced pluripotent stem cell (hiPSC)-derived cortical neurons. The activity of the cortical neurons was recorded by a 120-electrode multi-electrode array. Recordings were obtained at 0, 3, and 6 days after assembly and compared to those obtained from cortical neurons without a biopsy. On all three recording days, the hybrid model displayed a firing rate, burst behavior, number of isolated spikes, inter-spike interval, and network bursting pattern that aligns with the characteristics of an epileptic network as reported by others. Thus, this novel model may be a non-animal, translational alternative for testing new therapies up to six days after resection.
13 October 2021 in Journal of Vacuum Science & Technology B
This study presents sensing of network bursts in a three-dimensional (3D) cell culture system consisting of a microbioreactor and a multielectrode array (MEA), i.e., brain-on-chip, to interpret neural network dynamics in a label-free manner. While our initial results reported an increased single spiking activity already over the course of days 7, 14, and 21 in vitro, the advanced long-term analysis of the data set (including a last timepoint at day 79) here demonstrates a proof-of-principle for following bursting patterns upon maturation of the network in the microbioreactor as an add-on device for a commercial MEA recording system. These quantitative electrophysiological findings, including mean bursting rate, mean burst duration, and network burst dynamics, confirm a 2D to 3D transition in coherence with the literature.