This study aims to provide an accurate finite element (FE) modeling method for structural vibration serviceability evaluation of the suspended floor under human-induced excitation. The fundamental dynamic characteristics and human-induced vibration responses of a typical suspended floor were first measured via a series of field tests. Subsequently, the overall and local equivalent FE models of the suspended floor were respectively established, and their applicability was then verified by comparing the predicted dynamic characteristics and responses of the suspended floor with the corresponding field test results. Finally, passive tuned mass dampers (TMDs) were designed for vibration control of the suspended floor using the local equivalent FE model, and the applicability of the local FE model in assessing the vibration serviceability of the suspended floor with TMDs was further confirmed via pedestrian-induced vibration tests. Results demonstrate that the simplified local equivalent FE model proposed in this study can well replace the complicated overall FE model to evaluate the vibration serviceability of the suspended floor with and without TMDs.
25 March 2024 in International Journal of Structural Stability and Dynamics
Previous studies have demonstrated that two representative passive control devices, including inertial mass dampers (IMDs) and negative stiffness dampers (NSDs), exhibit superior control performance in single-mode vibration control of stay cables. However, observations in recent years have increasingly reported rain–wind-induced multi-mode vibrations of stay cables on actual bridges. Therefore, it is of considerable significance to investigate the control effectiveness of the two representative passive dampers in mitigating multi-mode cable vibrations. For this reason, this study presents a comparative study of the IMD and NSD for the multi-mode vibration control of stay cables. The mechanical models of typical IMDs and NSDs are first introduced, followed by the numerical modeling of the two cable-damper systems using the finite difference method. Subsequently, the effectiveness of three multi-mode optimization strategies is comprehensively assessed, and the most effective strategy is selected for the optimal design of the IMD and NSD. Finally, the effectiveness of the control of the IMD and NSD in suppressing harmonic, white noise and wind-induced multi-mode vibrations of a 493.72 (m) long ultra-long cable is systematically evaluated. The numerical results indicate that the NSD significantly improves the cable damping ratios for multiple vibration modes as its negative stiffness coefficient increases, while IMD performs well only within a small inertia coefficient. Moreover, the NSD outperforms the IMD in suppressing multi-mode cable vibrations induced by harmonic, white noise and wind excitations.
In recent years, power equipment has been developing towards low-carbon, high-efficiency, and green environmental protection. The double reheat unit has been increasingly employed in power plants due to its advantages of low energy consumption and less pollution. As a core component of power plants, the dynamic performance analysis of the steam turbine foundation is essential for ensuring the overall safety of double reheat unit. For this reason, the dynamic performance of a steam turbine foundation is investigated based on the engineering background of frame-type reinforced concrete foundations of 1000 MW double reheat steam turbine set in a power plant. The solid finite element model of the steam turbine foundation is first established by using ANSYS software, along with a detailed description of foundation information and modelling methodology. Subsequently, the dynamic characteristic and response analyses of the steam turbine foundation are performed to evaluate its dynamic performance, respectively. The results indicate that the 1000 MW steam turbine foundation demonstrates satisfactory dynamic performance. Within the operating speed range, the transverse, longitudinal, and vertical vibration displacements of the foundation bearings and columns remain below 20 μm, while the vibration velocity does not exceed 3.8 mm/s, both of which comply with relevant specifications. Moreover, enhancing the stiffness of the fifth and sixth beams, along with increasing the cross-sectional area of columns C3 and C4 on the steam turbine foundation, should be considered to mitigate its vibration responses and thus improve its dynamic performance. The research findings can serve as a reference for the type selection and optimization design of 1000 MW double reheat steam turbine foundations.