Purpose: The optimal duration of immobilization for the conservative treatment of non- or minimally displaced and displaced distal radius fractures remains under debate. This research aims to review studies of these treatments to add evidence regarding the optimal immobilization period. Methods: A comprehensive database search was conducted. Studies investigating and comparing short (< 3 weeks) versus long (> 3 weeks) immobilizations for the conservative treatment of distal radius fractures were included. The studies were evaluated for radiological and functional outcomes, including pain, grip strength, and range of motion. Two reviewers independently reviewed all studies and performed the data extraction. Results: The initial database search identified 11.981 studies, of which 16 (involving 1.118 patients) were ultimately included. Patient-reported outcome measurements, grip strength, range of motion, and radiological outcomes were often better after shorter immobilization treatments. Radiological outcomes were better with longer immobilization in two studies and shorter immobilization in one study. Fourteen studies concluded that early mobilization is preferred, while the remaining two studies observed better outcomes with longer immobilization. The data were unsuitable for meta-analysis due to their heterogeneous nature. Conclusion: Shorter immobilization for conservatively treated distal radius fractures often yield equal or better outcomes than longer immobilizations. The immobilization for non- or minimally displaced distal radius fractures could therefore be shortened to 3 weeks or less. Displaced and reduced distal radius fractures cannot be immobilized shorter than 4 weeks due to the risk of complications. Future research with homogeneous groups could elucidate the optimal duration of immobilization.
The distal radius fracture is a common fracture with a prevalence of 17% on the emergency departments. The conservative treatment of distal radius fractures usually consists of three to six weeks of plaster immobilization. Several studies show that one week of plaster immobilization is safe for non- or minimally displaced distal radius fractures that do not need reduction. A shorter period of immobilization may lead to a better functional outcome, faster reintegration and participation in daily activities. Due to upcoming innovations such as three-dimensional printed splints for distal radius fractures, a patient specific splint can be produced which may offer more comfort. Furthermore, these three-dimensional printed splints are expected to be more environmental friendly in comparison with traditional plaster casts.
Fractures of the superior pubic ramus can be treated with screw insertion into the osseous fixation pathway (OFP) of the anterior column (AC). The entry point determines whether the screw exits the OFP prematurely. This can be harmful when it enters the hip joint or damages soft tissues inside the lesser pelvis. The exact entry point varies between patients and can be difficult to ascertain on fluoroscopy during surgery. The aim of this study was to determine variation in the location of the entry point. A retrospective single center study was performed at a level 1 trauma center in the Netherlands. Nineteen adult patients were included with an undisplaced fracture of the superior pubic ramus on computer tomography (CT)-scan. Virtual three-dimensional (3D) models of the pelvises were created. Multiple screws were placed per AC and the models were superimposed. A total of 157 screws were placed, of which 109 did not exit the OFP prematurely. A universally reproducible entry point could not be identified. A typical crescent shaped region of entry points did exist and was located more laterally in females when compared to males. Three-dimensional virtual surgery planning can be helpful to identify the ideal entry points in each case.
Conventional treatment of traumatic extremity injuries involves immobilization with a gypsum or, plastic cast or splint. While effective, these devices can
Three-dimensional (3D) printed, patient-specific splints may offer an alternative for conventional immobilization methods by enhancing comfort, aeration, and hygiene. However, their broader clinical use remains limited by the complexity of current design workflows. Most existing workflows depend on 3D scans processed with commercial software and on manual or semi-automated CAD procedures that are difficult to reproduce, time-intensive, and often require pot-fit adjustments that are challenging to implement. A scalable modeling framework capable of capturing the substantial anatomical variability of the human forearm is needed to support more automated design pipelines. Morphable models address these limitations by establishing dense point-to-point correspondence across anatomical meshes, enabling a reference shape with fixed topology to deform through a set of parameters to approximate individual anatomies accurately. This study developed and validated a morphable forearm model using 200 structured light scans from 100 healthy adults (41 ± 19 years). Mesh preprocessing, anatomical alignment, and iterative registration were performed using a standardized framework, after which a statistical shape model was constructed and evaluated by comparing deformed mean shapes to original geometries using vertex-to-surface distance metrics. The model achieved a mean reconstruction error of 0.05 ± 0.11 mm, with the largest deviations near mesh boundaries at the hand and upper arm. These results demonstrate that the morphable model accurately represents forearm shape variability and provides a reproducible foundation for semi-automated, patient-specific splint design, thereby supporting the more efficient and clinically scalable implementation of 3D-printed immobilization solutions.
The conventional treatment for distal radius fractures typically involves immobilization of the injured extremity using a conventional forearm cast. These casts do cause all sorts of discomfort during wear and impose life-style restrictions on the wearer. Personalized 3D printed splints, designed using three-dimensional (3D) imaging systems, might overcome these problems. To obtain a patient specific splint, commercially available 3D camera systems are utilized to capture patient extremities, generating 3D models for splint design. This study investigates the feasibility of utilizing a new camera system (SPENTYS) to capture 3D surface scans of the forearm for the design of 3D printed splints. In a prospective observational cohort study involving 17 healthy participants, we conducted repeated 3D imaging using both the new (SPENTYS) and a reference system (3dMD) to assess intersystem accuracy and repeatability. The intersystem accuracy of the SPENTYS system was determined by comparison of the 3D surface scans with the reference system (3dMD). Comparison of consecutive images acquired per device determined the repeatability. Feasibility was measured with system usability score questionnaires distributed among professionals. The mean absolute difference between the two systems was 0.44 mm (SD:0.25). The mean absolute difference of the repeatability of the reference -and the SPENTYS system was respectively 0.40 mm (SD: 0.30) and 0.53 mm (SD: 0.25). Both repeatability and intersystem differences were within the self-reported 1 mm. The workflow was considered easy and effective, emphasizing the potential of this approach within a workflow to obtain patient specific splint.