Youngsam Yoon

Dr. Youngsam Yoon

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 September 2014 in Micro and Nano Systems Letters
Verified
Journal Article
Open access
PDF file
YYYoungsam Yoon
Youngsam Yoon
DKDaeyoung Kim
Daeyoung Kim
Jeong Bong (JB) LeeJeong Bong (JB) Lee
Jeong Bong (JB) Lee
Non-wetting super-hydrophobic or super-lyophobic surfaces are of great interest in a variety of applications. Natural water repelling surfaces show micro-/nano- combined hierarchical structure which shows extremely low wettability and self-cleaning characteristics. Inspired by such natural wonders, there have been tremendous efforts to create artificial non-wetting super-hydrophobic or super-lyophobic surfaces. In this paper, recent progress in artificial super-hydrophobic surfaces based on hierarchical micro-/nano- dual-scale structure is reviewed. In addition, application of hierarchical micro-/nano- dual-scale structure as super-lyophobic surfaces against gallium-based liquid metal alloy is also reviewed.

4 December 2013 in Sensors
Verified
Journal Article
Open access
PDF file
YYYoungsam Yoon
Youngsam Yoon
GLGil S. Lee
Gil S. Lee
KYKoangki Yoo
Koangki Yoo
Jeong Bong (JB) LeeJeong Bong (JB) Lee
Jeong Bong (JB) Lee
We report fabrication of a microneedle-based three-electrode integrated electrochemical sensor and in-vitro characterization of this sensor for glucose sensing applications. A piece of silicon was sequentially dry and wet etched to form a 15 × 15 array of tall (approximately 380 µm) sharp silicon microneedles. Iron catalyst was deposited through a SU-8 shadow mask to form the working electrode and counter electrode. A multi-walled carbon nanotube forest was grown directly on the silicon microneedle array and platinum nano-particles were electrodeposited. Silver was deposited on the Si microneedle array through another shadow mask and chlorinated to form a Ag/AgCl reference electrode. The 3-electrode electrochemical sensor was tested for various glucose concentrations in the range of 3~20 mM in 0.01 M phosphate buffered saline (PBS) solution. The sensor’s amperometric response to the glucose concentration is linear and its sensitivity was found to be 17.73 ± 3 μA/mM-cm2. This microneedle-based sensor has a potential to be used for painless diabetes testing applications.

14 February 2012 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
YYYoungsam Yoon
Youngsam Yoon
DLDong-Weon Lee
Dong-Weon Lee
Jeong Bong (JB) LeeJeong Bong (JB) Lee
Jeong Bong (JB) Lee