Background: Deformity assessment and preoperative planning of realignment surgery are conventionally based on weight-bearing (WB) radiographs. However, newer technologies such as three-dimensional (3D) preoperative planning and surgical navigation with patient-specific instruments (PSI) rely on non-weight bearing (NWB) computed tomography (CT) data. Additionally, differences between conventional two-dimensional (2D) and 3D measurements are known. The goal of the present study was to systematically analyse the influence of WB and the measurement modality (2D versus 3D) on common WB-dependent measurements used for deformity assessment. Methods: 85 lower limbs could be included. Two readers measured the hip-knee-ankle angle (HKA) and the joint line convergence angle (JLCA) in 2D WB and 2D NWB radiographs, as well as in CT-reconstructed 3D models using an already established 3D measurement method for HKA, and a newly developed 3D measurement method for JLCA, respectively. Interrater and intermodality reliability was assessed. Results: Significant differences between WB and NWB measurements were found for HKA (p < 0.001) and JLCA (p < 0.001). No significant difference could be observed between 2D HKA NWB and 3D HKA (p = 0.09). The difference between 2D JLCA NWB and 3D JLCA was significant (p < 0.001). The intraclass correlation coefficient (ICC) for the interrater agreement was almost perfect for all HKA and 3D JLCA measurements and substantial for 2D JLCA WB and 2D JLCA NWB. ICC for the intermodality agreement was almost perfect between 2D HKA WB and 2D HKA NWB as well as between 2D HKA NWB and 3D HKA, whereas it was moderate between 2D JLCA WB and 2D JLCA NWB and between 2D JLCA NWB and 3D JLCA. Conclusion: Limb loading results in significant differences for both HKA and JLCA measurements. Furthermore, 2D projections were found to be insufficient to represent 3D joint anatomy in complex cases. With an increasing number of surgical approaches based on NWB CT-reconstructed models, research should focus on the development of 3D planning methods that consider the effects of WB on leg alignment.
Objectives: 3D preoperative planning of lower limb osteotomies has become increasingly important in light of modern surgical technologies. However, 3D models are usually reconstructed from Computed Tomography data acquired in a non-weight-bearing posture and thus neglecting the positional variations introduced by weight-bearing. We developed a registration and planning pipeline that allows for 3D preoperative planning and subsequent 3D assessment of anatomical deformities in weight-bearing conditions.Methods: An intensity-based algorithm was used to register CT scans with long-leg standing radiographs and subsequently transform patient-specific 3D models into a weight-bearing state. 3D measurement methods for the mechanical axis as well as the joint line convergence angle were developed. The pipeline was validated using a leg phantom. Furthermore, we evaluated our methods clinically by applying it to the radiological data from 59 patients.Results: The registration accuracy was evaluated in 3D and showed a maximum translational and rotational error of 1.1 mm (mediolateral direction) and 1.2° (superior-inferior axis). Clinical evaluation proved feasibility on real patient data and resulted in significant differences for 3D measurements when the effects of weight-bearing were considered. Mean differences were 2.1 ± 1.7° and 2.0 ± 1.6° for the mechanical axis and the joint line convergence angle, respectively. 37.3 and 40.7% of the patients had differences of 2° or more in the mechanical axis or joint line convergence angle between weight-bearing and non-weight-bearing states.Conclusions: Our presented approach provides a clinically feasible approach to preoperatively fuse 2D weight-bearing and 3D non-weight-bearing data in order to optimize the surgical correction.
4 April 2024 in International Journal of Computer Assisted Radiology and Surgery
Purpose: Three-dimensional (3D) preoperative planning has become the gold standard for orthopedic surgeries, primarily relying on CT-reconstructed 3D models. However, in contrast to standing radiographs, a CT scan is not part of the standard protocol but is usually acquired for preoperative planning purposes only. Additionally, it is costly, exposes the patients to high doses of radiation and is acquired in a non-weight-bearing position. Methods: In this study, we develop a deep-learning based pipeline to facilitate 3D preoperative planning for high tibial osteotomies, based on 3D models reconstructed from low-dose biplanar standing EOS radiographs. Using digitally reconstructed radiographs, we train networks to localize the clinically required landmarks, separate the two legs in the sagittal radiograph and finally reconstruct the 3D bone model. Finally, we evaluate the accuracy of the reconstructed 3D models for the particular application case of preoperative planning, with the aim of eliminating the need for a CT scan in specific cases, such as high tibial osteotomies. Results: The mean Dice coefficients for the tibial reconstructions were 0.92 and 0.89 for the right and left tibia, respectively. The reconstructed models were successfully used for clinical-grade preoperative planning in a real patient series of 52 cases. The mean differences to ground truth values for mechanical axis and tibial slope were 0.52° and 4.33°, respectively. Conclusions: We contribute a novel framework for the 2D–3D reconstruction of bone models from biplanar standing EOS radiographs and successfully use them in automated clinical-grade preoperative planning of high tibial osteotomies. However, achieving precise reconstruction and automated measurement of tibial slope remains a significant challenge.
Acetabular retroversion results in reduced range of motion, and is thought to contribute to femoroacetabular impingement. Severe retroversion can be corrected with a periacetabular osteotomy, which is a technically demanding intervention. In this study, we investigated whether increasing femoral antetorsion is a potential alternative to restore the range of motion and how this approach would affect hip joint loading. Six different finite element models of the same subject were built from MRI and used to simulate different load scenarios during stance phase, including healthy and pathological configurations with different acetabular version and femoral torsion angles. The subject's gait was analysed in our gait lab and motion data as well as joint reaction forces were integrated into the model. Hip range of motion, hip abductor muscle forces as well as localization and magnitude of hip joint loads were determined. The negative effects of acetabular retroversion on hip range of motion including flexion and internal rotation can be reversed by increasing femoral anteversion. The rotation of the femur furthermore affected muscular functionality by shortening the moment arms of the hip abductor muscles, resulting in increased abductor muscle forces, joint reaction forces and hip joint loading. Even though increased femoral antetorsion can compensate for the loss of hip range of motion due to reduced acetabular version, rotational ostotomy of the proximal femur is likely to alter muscular moment arms and therefore increase hip joint load, conflicting the goal of a long-term healthy joint.
30 March 2024 in Archives of orthopaedic and trauma surgery
Background: The use of 3D planning to guide corrective osteotomies of the lower extremity is increasing in clinical practice. The use of computer-tomography (CT) data acquired in supine position neglects the weight-bearing (WB) state and the gold standard in 3D planning involves the manual adaption of the surgical plan after considering the WB state in long-leg radiographs (LLR). However, this process is subjective and dependent on the surgeons experience. A more standardized and automated method could reduce variability and decrease costs. Purpose: The aim of the study was (1) to compare three different three-dimensional (3D) planning modalities for medial open-wedge high tibial osteotomy (MOWHTO) and (2) to describe the current practice of adapting NWB CT data after considering the WB state in LLR. The purpose of this study is to validate a new, standardized approach to include the WB state into the 3D planning and to compare this method against the current gold standard of 3D planning. Our hypothesis is that the correction is comparable to the gold standard, but shows less variability due compared to the more subjective hybrid approach. Methods: Three surgical planning modalities were retrospectively analyzed in 43 legs scheduled for MOWHTO between 2015 and 2019. The planning modalities included: (1) 3D hybrid (3D non-weight-bearing (NWB) CT models after manual adaption of the opening angle considering the WB state in LLR, (2) 3D NWB (3D NWB CT models) and (3) 3D WB (2D/3D registration of 3D NWB CT models onto LLR to simulate the WB state). The pre- and postoperative hip-knee-ankle angle (HKA) and the planned opening angle (°) were assessed and differences among modalities reported. The relationship between the reported differences and BMI, preoperative HKA (LLR), medial meniscus extrusion, Outerbridge osteoarthritis grade and joint line convergence angle (JLCA) was analyzed. Results: The mean (std) planned opening angle of 3D hybrid did not differ between 3D hybrid and 3D WB (0.4 ± 2.1°) (n.s.) but was higher in 3D hybrid compared to 3D NWB (1.1° ± 1.1°) (p = 0.039). 3D WB demonstrated increased preoperative varus deformity compared to 3D NWB: 6.7 ± 3.8° vs. 5.6 ± 2.7° (p = 0.029). Patients with an increased varus deformity in 3D WB compared to 3D NWB (> 2 °) demonstrated more extensive varus alignment in LLR (p = 0.009) and a higher JLCA (p = 0.013). Conclusion: Small intermodal differences between the current practice of the reported 3D hybrid planning modality and a 3D WB approach using a 2D/3D registration algorithm were reported. In contrast, neglecting the WB state underestimates preoperative varus deformity and results in a smaller planned opening angle. This leads to potential under correction in MOWHTO, especially in patients with extensive varus deformities or JLCA. Clinical Relevance: Incorporating the WB state in 3D planning modalities has the potential to increase accuracy and lead to a more consistent and reliable planning in MOWHTO. The inclusion of the WB state in automatized surgical planning algorithms has the potential to reduce costs and time in the future.
Three-dimensional (3D) deformity assessment and leg realignment planning is emerging. The aim of this study was to (1) validate a novel 3D planning modality that incorporates the weight-bearing (WB) state (3D WB) by comparing it to existing modalities (3D non-weight-bearing (NWB), 2D WB) and (2) evaluate the influence of the modality (2D vs. 3D) and the WB condition on the measurements. Three different planning and deformity measurement protocols were analyzed in 19 legs that underwent medial open-wedge high tibial osteotomy (HTO): (1) a 3D WB protocol, after 2D/3D registration of 3D CT models onto the long-leg radiograph (LLR) (3D WB), (2) a 3D NWB protocol based on the 3D surface models obtained in the supine position (3D NWB), and (3) a 2D WB protocol based on the LLR (2D WB). The hip–knee–ankle angle (HKA), joint line convergence angle (JLCA), and the achieved surgical correction were measured for each modality and patient. All the measurement protocols demonstrated excellent intermodal agreement for the achieved surgical correction, with an ICC of 0.90 (95% CI: 0.76–0.96)) (p < 0.001). Surgical correction had a higher mean absolute difference compared to the 3D opening angle (OA) when measured with the WB protocols (3D WB: 2.7 ± 1.8°, 3D NWB: 1.9 ± 1.3°, 2D WB: 2.2 ± 1.3°), but it did not show statistical significance. The novel planning modality (3D WB) demonstrated excellent agreement when measuring the surgical correction after HTO compared to existing modalities.