Mahinda Vilathgamuwa

Prof. Mahinda Vilathgamuwa

orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 September 2004 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
YLYunwei Li
Yunwei Li
MVMahinda Vilathgamuwa
Mahinda Vilathgamuwa
PLPoh Chiang Loh
Poh Chiang Loh
This paper concentrates on the design and analysis of a controller for multibus microgrid system. The controller proposed for use with each distributed generation (DG) system in the microgrid contains inner voltage and current loops for regulating the three-phase grid-interfacing inverter, and external power control loops for controlling real and reactive power flow and for facilitating power sharing between the paralleled DG systems when a utility fault occurs and the microgrid islands. The controller also incorporates synchronization algorithms for ensuring smooth and safe reconnection of the micro and utility grids when the fault is cleared. With the implementation of the unified controller, the multibus microgrid system is able to switch between islanding and grid-connected modes without disrupting the critical loads connected to it. The performance of this unified controller has been verified in simulation using a real-time digital simulator and experimentally using a scaled laboratory prototype.

7 November 2005 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
PLPoh Chiang Loh
Poh Chiang Loh
MVMahinda Vilathgamuwa
Mahinda Vilathgamuwa
YLY.S. Lai
Y.S. Lai
GCGeok Tin Chua
Geok Tin Chua
YLY. Li
Y. Li
Z-Source inverters have recently been proposed as an alternative power conversion concept as they have both voltage buck and boost capabilities. These inverters use a unique impedance network, coupled between the power source and converter circuit, to provide both voltage buck and boost properties, which cannot be achieved with conventional voltage-source and current-source inverters. To facilitate understanding of Z-source inverter modulation, this paper presents a detailed analysis, showing how various conventional pulse-width modulation strategies can be modified to switch a voltage-type Z-source inverter either continuously or discontinuously, while retaining all the unique harmonic performance features of these conventional modulation strategies. This paper starts by analyzing the modulation requirements of a single-phase H-bridge Z-source inverter, and subsequently extends the analysis to cover the more complex three-phase-leg and four-phase-leg Z-source inverters, with carrier-based implementation reference equations derived for all the inverters. The theoretical and modulation concepts presented have been verified both in simulation and experimentally.

1 February 2013 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
GFGilbert Hock Beng Foo
Gilbert Hock Beng Foo
XZXinan Zhang
Xinan Zhang
MVMahinda Vilathgamuwa
Mahinda Vilathgamuwa
Interior permanent-magnet synchronous motors (IPMSMs) become attractive candidates in modern hybrid electric vehicles and industrial applications. Usually, to obtain good control performance, the electric drives of this kind of motor require one position, one dc link, and at least two current sensors. Failure of any of these sensors might lead to degraded system performance or even instability. As such, sensor fault resilient control becomes a very important issue in modern drive systems. This paper proposes a novel sensor fault detection and isolation algorithm based on an extended Kalman filter. It is robust to system random noise and efficient in real-time implementation. Moreover, the proposed algorithm is compact and can detect and isolate all the sensor faults for IPMSM drives. Thorough theoretical analysis is provided, and the effectiveness of the proposed approach is proven by extensive experimental results.

21 November 2005 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
YLYunwei Li
Yunwei Li
MVMahinda Vilathgamuwa
Mahinda Vilathgamuwa
PLPoh Chiang Loh
Poh Chiang Loh
This paper presents a three-phase four-wire grid-interfacing power quality compensator for microgrid applications. The compensator is proposed for use with each individual distributed generation (DG) system in the microgrid and consists of two four-phase-leg inverters (a shunt and a series), optimally controlled to achieve an enhancement of both the quality of power within the microgrid and the quality of currents flowing between the microgrid and the utility system. During utility grid voltage unbalance, the four-phase-leg compensator can compensate for all the unwanted positive-, negative-, and zero-sequence voltage-current components found within the unbalanced utility. Specifically, the shunt four-leg inverter is controlled to ensure balanced voltages within the microgrid and to regulate power sharing among the parallel-connected DG systems. The series inverter is controlled complementarily to inject negative- and zero-sequence voltages in series to balance the line currents, while generating zero real and reactive power. During utility voltage sags, the series inverter can also be controlled using a newly proposed flux-charge current-limiting algorithm to limit the flow of large fault currents between the micro- and utility grids. The performance of the proposed compensator has been verified in simulations and experimentally using a laboratory prototype.

2 May 2008 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
XWX. Y. Wang
X. Y. Wang
MVMahinda Vilathgamuwa
Mahinda Vilathgamuwa
SCS. S. Choi
S. S. Choi
Design of a battery energy storage system (BESS) in a buffer scheme is examined for the purpose of attenuating the effects of unsteady input power from wind farms. The design problem is formulated as maximization of an objective function that measures the economic benefit obtainable from the dispatched power from the wind farm against the cost of the BESS. Solution to the problem results in the determination of the capacity of the BESS to ensure constant dispatched power to the connected grid, while the voltage level across the dc-link of the buffer is kept within preset limits. A computational procedure to determine the BESS capacity and the evaluation of the dc voltage is shown. Illustrative examples using the proposed design method are included.

8 March 2010 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
SZShao Zhang
Shao Zhang
KTKing-Jet Tseng
King-Jet Tseng
MVMahinda Vilathgamuwa
Mahinda Vilathgamuwa
TNTrong Duy Nguyen
Trong Duy Nguyen
XWXiao-Yu Wang
Xiao-Yu Wang
A robust and reliable grid power interface system for wind turbines using a permanent-magnet synchronous generator (PMSG) is proposed in this paper, where an integration of a generator-side three-switch buck-type rectifier and a grid-side Z-source inverter is employed as a bridge between the generator and the grid. The modulation strategy for the proposed topology is developed from space-vector modulation and Z-source network operation principles. Two PMSG control methods, namely, unity-power-factor control and rotor-flux-orientation control (Id = 0), are studied to establish an optimized control scheme for the generator-side three-switch buck-type rectifier. The system control scheme decouples active- and reactive-power control through voltage-oriented control and optimizes PMSG control for the grid- and generator-side converters independently. Maximum power point tracking is implemented by adjusting the shoot-through duty cycles of the Z-source network. The design considerations of the passive components are also provided. The performances and practicalities of the designed architecture have been verified by simulations and experiments.