8 March 2010 in IEEE Transactions on Industrial Electronics
A robust and reliable grid power interface system for wind turbines using a permanent-magnet synchronous generator (PMSG) is proposed in this paper, where an integration of a generator-side three-switch buck-type rectifier and a grid-side Z-source inverter is employed as a bridge between the generator and the grid. The modulation strategy for the proposed topology is developed from space-vector modulation and Z-source network operation principles. Two PMSG control methods, namely, unity-power-factor control and rotor-flux-orientation control (Id = 0), are studied to establish an optimized control scheme for the generator-side three-switch buck-type rectifier. The system control scheme decouples active- and reactive-power control through voltage-oriented control and optimizes PMSG control for the grid- and generator-side converters independently. Maximum power point tracking is implemented by adjusting the shoot-through duty cycles of the Z-source network. The design considerations of the passive components are also provided. The performances and practicalities of the designed architecture have been verified by simulations and experiments.
28 October 2010 in IEEE Transactions on Industrial Electronics
This paper presents the design and analysis of a novel axial flux permanent-magnet (AFPM) machine for a flywheel energy storage system (FESS). Its design and control facilitate significant reduction in axial bearing stress and losses. Due to the unconventional flux distribution in this machine, a 3-D finite element method was employed for its design and analysis, including its electromagnetic torque and axial force performances. The effects of the rotor PM skew angle on the cogging torque and the axial force have been studied. It is found that an optimum skew angle is effective in reducing the overall cogging torque with negligible effect on the static axial force. The latter is crucial as it can be utilized to minimize the axial bearing stress in FESS application. The concept, design, and analysis methodology have been validated by experimental results from an experimental AFPM machine prototype.
27 June 2011 in IEEE Transactions on Power Electronics
Due to increasing wind power penetration into utility grids, system operators have instituted stringent standards for ride-through compliance of grid-connected wind turbines. Series voltage compensation can be an effective solution to meet the new standards, especially if a low-cost system can be developed. This paper first presents the characteristics of ride-through behavior of doubly fed induction generator (DFIG) using phasor analysis. The analysis is extended to include the effects of generic series voltage compensation. A new control scheme is then described and analyzed, which allows relatively low-energy ratings in the series compensator, thereby significantly lowering the overall system cost. The new controller enables the DFIG with the compensator to provide the reactive power required for system voltage recovery during grid fault, in compliance with the new grid codes. Simulation and experimental results have demonstrated the enhanced performances resulting from the application of the control scheme.
8 October 2002 in Biosensors and Bioelectronics
1 January 2000 in Analytical Letters
AEAlexander A. Echevarria
A fluorescent biosensor was developed on a KinExATM flow spectrofluorimeter for the near real-time detection of soluble zeaalenone. Briefly, solutions of zearalenone and a monoclonal antibody directed against a protein conjugate of zearalenone, were incubated for thirty minutes to permit equilibrium binding to occur. The reaction mixture was then passed over a packed column of small beads (98 μm) whose surfaces were coated with a covalent conjugate of zearalenone and bovine serum albumin (BSA). Following a short wash with buffer to remove excess unbound primary reagents, the packed beads were subjected to a brief contact with fluorescein isothiocyanate-labeled polyclonal secondary antibody directed against the primary monoclonal, once again followed by a short wash. As this assay depends on the ability of soluble antigen to compete with immobilized antigen, increasing concentrations of zearalenone result in decreasing fluorescence observed on the bead pack. This assay is rapid (≅ 60 minutes) and can be adapted to various other analytes of interest.