Stefan Lang

Dr. Stefan Lang


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
MSManuel Schmidt
Manuel Schmidt
TETobias Engelhorn
Tobias Engelhorn
SLStefan Lang
Stefan Lang
HLHannes Luecking
Hannes Luecking
PHPhilip Hoelter
Philip Hoelter
ADArnd Doerfler
Arnd Doerfler
Background: SPECT (single-photon emission-computed tomography) is used for the detection of hypoperfusion in cognitive impairment and dementia but is not widely available and related to radiation dose exposure. We compared the performance of DSC (dynamic susceptibility contrast) perfusion using semi- and fully adaptive deconvolution models to HMPAO-SPECT (99mTc-hexamethylpropyleneamine oxime-SPECT). Material and Methods: Twenty-seven patients with dementia of different subtypes including frontotemporal dementia (FTD) and mild cognitive impairment (MCI) received a multimodal diagnostic work-up including DSC perfusion at a clinical 3T high-field scanner and HMPAO-SPECT. Nineteen healthy control individuals received DSC perfusion. For calculation of the hemodynamic parameter maps, oscillation-index standard truncated singular value decomposition (oSVD, semi-adaptive) as well as Bayesian parameter estimation (BAY, fully adaptive) were performed. Results: Patients showed decreased cortical perfusion in the left frontal lobe compared to controls (relative cerebral blood volume corrected, rBVc: 0.37 vs. 0.27, p = 0.048, adjusted for age and sex). Performance of rBVc (corrected for T1 effects) was highest compared to SPECT for detection of frontal hypoperfusion (sensitivity 83%, specificity 80% for oSVD and BAY, area under curve (AUC) = 0.833 respectively, p < 0.05) in FTD and MCI. For nonleakage-corrected rBV and for rBF (relative cerebral blood flow), sensitivity of frontal hypoperfusion was above 80% for oSVD and for BAY (rBV: sensitivity 83%, specificity 75%, AUC = 0.908 for oSVD and 0.917 for BAY, p < 0.05 respectively; rBF: sensitivity 83%, specificity 65%, AUC = 0.825, p < 0.05 for oSVD). Conclusion: Advanced deconvolution DSC can reliably detect pathological perfusion alterations in FTD and MCI. Hence, this widely accessible technique has the potential to improve the diagnosis of dementia and MCI as part of an interdisciplinary multimodal imaging work-up. Advances in knowledge: Advanced DSC perfusion has a high potential in the work-up of suspected dementia and correlates with SPECT brain perfusion results in dementia and MCI.

17 January 2022 in Tomography
Verified
Journal Article
Open access
PDF file
DMDominique Cornelius Marterstock
Dominique Cornelius Marterstock
MKMichael Knott
Michael Knott
PHPhilip Hoelter
Philip Hoelter
SLStefan Lang
Stefan Lang
TOTimo Oberstein
Timo Oberstein
MSManuel Schmidt
Manuel Schmidt
Background: Previous studies suggest that brain atrophy can not only be defined by its morphological extent, but also by the cerebral blood flow (CBF) within a certain area of the brain, including white and gray matter. The aim of this study is to investigate known atrophy patterns in different forms of dementia and to compare segmented brain volumetrics and pulsed arterial spin labeling (pASL) data to explore the correlation between brain maps with atrophy and this non-contrast-enhanced brain-perfusion method. Methods: Our study comprised 17 patients with diagnosed cognitive impairment (five Alzheimer’s disease = AD, five frontotemporal dementia = FTD, seven mild cognitive impairment = MCI) and 19 healthy control subjects (CO). All patients and controls underwent 4D-pASL brain-perfusion MR imaging and T1w MPRAGE. The data were assessed regarding relative brain volume on the basis of 286 brain regions, and absolute and relative cerebral blood flow (CBF/rCBF) were derived from pASL data in the corresponding brain regions. Mini-Mental State Examination (MMSE) was performed to assess cognitive functions. Results: FTD patients demonstrated significant brain atrophy in 43 brain regions compared to CO. Patients with MCI showed significant brain atrophy in 18 brain regions compared to CO, whereas AD patients only showed six brain regions with significant brain atrophy compared to CO. There was good correlation of brain atrophy and pASL perfusion data in five brain regions of patients with diagnosed FTD, especially in the superior temporal gyrus (r = 0.900, p = 0.037), the inferior frontal white matter (pars orbitalis; r = 0.968, p = 0.007) and the thalami (r = 0.810, p = 0.015). Patients with MCI demonstrated a correlation in one brain region (left inferior fronto-occipital fasciculus; r = 0.786, p = 0.036), whereas patients with diagnosed AD revealed no correlation. Conclusions: pASL can detect affected brain regions in cognitive impairment and corresponds with brain atrophy, especially for patients suffering from FTD and MCI. However, there was no correlation of perfusion alterations and brain atrophy in AD. pASL perfusion might thus represent a promising tool for noninvasive brain-perfusion evaluation in specific dementia subtypes as a complimentary imaging-based bio marker in addition to brain volumetry.

14 February 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
SLStefan Lang
Stefan Lang
PHPhilip Hoelter
Philip Hoelter
MSManuel Schmidt
Manuel Schmidt
AMAnne Mrochen
Anne Mrochen
JKJoji Kuramatsu
Joji Kuramatsu
ADArnd Doerfler
Arnd Doerfler
Background and purpose: Based on artificial intelligence (AI), 3D angiography (3DA) is a novel postprocessing algorithm for “DSA-like” 3D imaging of cerebral vasculature. Because 3DA requires neither mask runs nor digital subtraction as the current standard 3D-DSA does, it has the potential to cut the patient dose by 50%. The object was to evaluate 3DA’s diagnostic value for visualization of intracranial artery stenoses (IAS) compared to 3D-DSA. Materials and methods: 3D-DSA datasets of IAS (nIAS = 10) were postprocessed using conventional and prototype software (Siemens Healthineers AG, Erlangen, Germany). Matching reconstructions were assessed by two experienced neuroradiologists in consensus reading, considering image quality (IQ), vessel diameters (VD1/2), vessel-geometry index (VGI = VD1/VD2), and specific qualitative/quantitative parameters of IAS (e.g., location, visual IAS grading [low-/medium-/high-grade] and intra-/poststenotic diameters [dintra-/poststenotic in mm]). Using the NASCET criteria, the percentual degree of luminal restriction was calculated. Results: In total, 20 angiographic 3D volumes (n3DA = 10; n3D-DSA = 10) were successfully reconstructed with equivalent IQ. Assessment of the vessel geometry in 3DA datasets did not differ significantly from 3D-DSA (VD1: r = 0.994, p = 0.0001; VD2:r = 0.994, p = 0.0001; VGI: r = 0.899, p = 0.0001). Qualitative analysis of IAS location (3DA/3D-DSA:nICA/C4 = 1, nICA/C7 = 1, nMCA/M1 = 4, nVA/V4 = 2, nBA = 2) and the visual IAS grading (3DA/3D-DSA:nlow-grade = 3, nmedium-grade = 5, nhigh-grade = 2) revealed identical results for 3DA and 3D-DSA, respectively. Quantitative IAS assessment showed a strong correlation regarding intra-/poststenotic diameters (rdintrastenotic = 0.995, pdintrastenotic = 0.0001; rdpoststenotic = 0.995, pdpoststenotic = 0.0001) and the percentual degree of luminal restriction (rNASCET 3DA = 0.981; pNASCET 3DA = 0.0001). Conclusions: The AI-based 3DA is a resilient algorithm for the visualization of IAS and shows comparable results to 3D-DSA. Hence, 3DA is a promising new method that allows a considerable patient-dose reduction, and its clinical implementation would be highly desirable.

4 May 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
FEFelix Eisenhut
Felix Eisenhut
MSManuel Schmidt
Manuel Schmidt
AKAlexander Kalik
Alexander Kalik
TSTobias Struffert
Tobias Struffert
JFJulian Feulner
Julian Feulner
SLStefan Lang
Stefan Lang
Treated cerebral aneurysms (IA) require follow-up imaging to ensure occlusion. Metal artifacts complicate radiologic assessment. Our aim was to evaluate an innovative metal-artifact-reduction (iMAR) algorithm for flat-detector computed tomography angiography (FD-CTA) regarding image quality (IQ) and detection of aneurysm residua/reperfusion in comparison to 2D digital subtraction angiography (DSA). Patients with IAs treated by endovascular coiling or clipping underwent both FD-CTA and DSA. FD-CTA datasets were postprocessed with/without iMAR algorithm (MAR+/MAR−). Evaluation of all FD-CTA and DSA datasets regarding qualitative (IQ, MAR) and quantitative (coil package diameter/CPD) parameters was performed. Aneurysm occlusion was assessed for each dataset and compared to DSA findings. In total, 40 IAs were analyzed (ncoiling = 24; nclipping = 16). All iMAR+ datasets demonstrated significantly better IQ (pIQ coiling < 0.0001; pIQ clipping < 0.0001). iMAR significantly reduced the metal-artifact burden but did not affect the CPD. iMAR significantly improved the detection of aneurysm residua/reperfusion with excellent agreement with DSA (naneurysm detection MAR+/MAR−/DSA = 22/1/26). The iMAR algorithm significantly improves IQ by effective reduction of metal artifacts in FD-CTA datasets. The proposed algorithm enables reliable detection of aneurysm residua/reperfusion with good agreement to DSA. Thus, iMAR can help to reduce the need for invasive follow-up in treated IAs.

31 July 2025 in Brain Sciences
Verified
Journal Article
Open access
PDF file
LSLudwig Singer
Ludwig Singer
DHDaniel Heinze
Daniel Heinze
TMTim Alexius Möhle
Tim Alexius Möhle
ASAlexander Sekita
Alexander Sekita
AMAngelika Mennecke
Angelika Mennecke
MSManuel Schmidt
Manuel Schmidt
Objective: This study aimed to evaluate whether modifying the post-processing algorithm of Twin-Spiral Dual-Energy computed tomography (DECT) improves infarct detection compared to conventional Dual-Energy CT (DECT) and Single-Energy CT (SECT) following endovascular therapy (EVT) for large vessel occlusion (LVO). Methods: We retrospectively analyzed 52 patients who underwent Twin-Spiral DECT after endovascular stroke therapy. Ten patients were used to generate a device-specific parameter (“y”) using an AI-based neural network (SynthSR). This parameter was integrated into the post-processing algorithm for edema map generation. Quantitative Hounsfield unit (HU) measurements were used to assess density differences in ischemic brain tissue across conventional virtual non-contrast (VNC) images and edema maps. Results: The median HU of infarcted tissue in conventional mixed DECT was 33.73 ± 4.58, compared to 22.96 ± 3.81 in default VNC images. Edema maps with different smoothing filter settings showed values of 14.39 ± 4.96, 14.50 ± 3.75, and 15.05 ± 2.65, respectively. All edema maps demonstrated statistically significant HU differences of infarcted tissue compared to conventional VNC images (p<0.001) while maintaining the density values of non-infarcted brain tissue. Conclusions: Enhancing the post-processing algorithm of conventional virtual non-contrast imaging improves infarct detection compared to standard mixed or virtual non-contrast reconstructions in Dual-Energy CT.

19 January 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
LSLudwig Singer
Ludwig Singer
TMTim Alexius Möhle
Tim Alexius Möhle
AMAngelika Mennecke
Angelika Mennecke
KHKonstantin Huhn
Konstantin Huhn
VRVeit Rothhammer
Veit Rothhammer
SLStefan Lang
Stefan Lang
Background: Automated AI-based brain volumetry is increasingly used in clinical practice. T1-weighted sequences (e.g., MPRAGE) are considered the current state-of-the art. However, due to faster acquisition and higher in-plane resolution, 2D anisotropic sequences are often preferred in clinical routine. However, these sequences cannot be processed with currently available AI-volumetry software. Thus, we here aimed to evaluate volumetric data from synthetic MPRAGE-like sequences (mprAIge). Methods: We analyzed 412 datasets (206 conventional MPRAGE and 206 T2w/FLAIR) from healthy volunteers (n = 36) and patients with multiple sclerosis (n = 140). Synthetic mprAIge was generated using SynthSR-CNN and assessed via assemblyNET on the volBrain platform. Total brain volume (TBV), gray and white matter volume (GMV/WMV), and key substructures were compared between mprAIge and conventional MPRAGE. Average volume differences (AVDs) and correlations were calculated. Results: Synthetic mprAIge was generated successfully in all 206 cases. Quantitative analysis demonstrated strong correlation and high agreement for key substructures. TBV showed excellent agreement (AVD: 2.75% for controls, 3.90% for MS patients; r = 0.99 and 0.97, respectively). White matter volume exhibited excellent agreement (AVD: −1.92% for controls, 0.28% for MS patients; r = 0.95). Hippocampal volume also demonstrated good to excellent agreement (AVD: 1.13% for controls, −1.92% for MS patients; r = 0.91 and 0.89, respectively). Conclusions: Synthetic mprAIge enables AI-volumetry software application without limitations. Its volumetric assessments align well with conventional MPRAGE, opening new opportunities for volumetric post-processing and mapping of disease progression.