Tim Alexius Möhle

Mr. Tim Alexius Möhle


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 July 2025 in Brain Sciences
Verified
Journal Article
Open access
PDF file
LSLudwig Singer
Ludwig Singer
DHDaniel Heinze
Daniel Heinze
TMTim Alexius Möhle
Tim Alexius Möhle
ASAlexander Sekita
Alexander Sekita
AMAngelika Mennecke
Angelika Mennecke
MSManuel Schmidt
Manuel Schmidt
Objective: This study aimed to evaluate whether modifying the post-processing algorithm of Twin-Spiral Dual-Energy computed tomography (DECT) improves infarct detection compared to conventional Dual-Energy CT (DECT) and Single-Energy CT (SECT) following endovascular therapy (EVT) for large vessel occlusion (LVO). Methods: We retrospectively analyzed 52 patients who underwent Twin-Spiral DECT after endovascular stroke therapy. Ten patients were used to generate a device-specific parameter (“y”) using an AI-based neural network (SynthSR). This parameter was integrated into the post-processing algorithm for edema map generation. Quantitative Hounsfield unit (HU) measurements were used to assess density differences in ischemic brain tissue across conventional virtual non-contrast (VNC) images and edema maps. Results: The median HU of infarcted tissue in conventional mixed DECT was 33.73 ± 4.58, compared to 22.96 ± 3.81 in default VNC images. Edema maps with different smoothing filter settings showed values of 14.39 ± 4.96, 14.50 ± 3.75, and 15.05 ± 2.65, respectively. All edema maps demonstrated statistically significant HU differences of infarcted tissue compared to conventional VNC images (p<0.001) while maintaining the density values of non-infarcted brain tissue. Conclusions: Enhancing the post-processing algorithm of conventional virtual non-contrast imaging improves infarct detection compared to standard mixed or virtual non-contrast reconstructions in Dual-Energy CT.

19 January 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
LSLudwig Singer
Ludwig Singer
TMTim Alexius Möhle
Tim Alexius Möhle
AMAngelika Mennecke
Angelika Mennecke
KHKonstantin Huhn
Konstantin Huhn
VRVeit Rothhammer
Veit Rothhammer
SLStefan Lang
Stefan Lang
Background: Automated AI-based brain volumetry is increasingly used in clinical practice. T1-weighted sequences (e.g., MPRAGE) are considered the current state-of-the art. However, due to faster acquisition and higher in-plane resolution, 2D anisotropic sequences are often preferred in clinical routine. However, these sequences cannot be processed with currently available AI-volumetry software. Thus, we here aimed to evaluate volumetric data from synthetic MPRAGE-like sequences (mprAIge). Methods: We analyzed 412 datasets (206 conventional MPRAGE and 206 T2w/FLAIR) from healthy volunteers (n = 36) and patients with multiple sclerosis (n = 140). Synthetic mprAIge was generated using SynthSR-CNN and assessed via assemblyNET on the volBrain platform. Total brain volume (TBV), gray and white matter volume (GMV/WMV), and key substructures were compared between mprAIge and conventional MPRAGE. Average volume differences (AVDs) and correlations were calculated. Results: Synthetic mprAIge was generated successfully in all 206 cases. Quantitative analysis demonstrated strong correlation and high agreement for key substructures. TBV showed excellent agreement (AVD: 2.75% for controls, 3.90% for MS patients; r = 0.99 and 0.97, respectively). White matter volume exhibited excellent agreement (AVD: −1.92% for controls, 0.28% for MS patients; r = 0.95). Hippocampal volume also demonstrated good to excellent agreement (AVD: 1.13% for controls, −1.92% for MS patients; r = 0.91 and 0.89, respectively). Conclusions: Synthetic mprAIge enables AI-volumetry software application without limitations. Its volumetric assessments align well with conventional MPRAGE, opening new opportunities for volumetric post-processing and mapping of disease progression.