This study mainly discusses the implications of solar radiation profiles and changes in load with respect to base load conditions on the PV placement, size, voltage violations, and curtailment cost of PV generation in the network. The PV installation is optimized using yearly solar radiation profiles, low, medium, and high, corresponding to three different locations. The network in the study is represented as a multiphase, with provision for the installation of both single- and three-phase PV systems. For the different load changes in either one of the phases or all three phases, the optimal placement and size of PV inverters are discussed. It is indicated that with load increase in all three phases, for low solar radiation profiles, the placement and size of PVs remain non-uniform, while for medium and high solar radiation, the distribution becomes comparatively uniform throughout the network. However, with a load increase in one of the phases, for low solar radiation, optimal placement compensates with three-phase PV installation, while for medium/high solar, the corresponding load increase phase contributes to greater PV installation. The voltage rise is observed at both load-connected and non-load-connected buses. Such buses in the network are those that form the common junction with the branches connected to another set of buses having optimally placed PVs. The voltage violations are experienced at the feeder end buses with single-phase PV installation, not only in the phase having a connected load but also in one of the other phases.
30 September 2023 in International Transactions on Electrical Energy Systems
Integration of large-scale distributed photovoltaic (PV) generation resources can lead to technical challenges, particularly voltage rise caused by PVs power injection at the time of high solar radiation profile and low load demand. Reactive power control of PV inverters can help mitigate the voltage rise, which arises just for a short duration due to high incident solar radiation. There is a possibility to control functions on these PV inverters based on the rating of the PV inverter. For one-second resolution, local data-driven voltage sensitivity estimation is applied to update the control functions such as volt-var and volt-watt on the PV inverters so as to regulate the bus voltage. Different forms of solar radiation profiles, transient varying, smooth varying, and worst operating scenario corresponding to the minimum load at the time of high PV generation, are included. The study is demonstrated for different PV penetration levels. The voltage analysis on buses is performed using power hardware (PV emulator) in the loop simulation, at one of the buses in the network, while the remaining PVs are being controlled using volt-var control (VVC)/volt-watt control (VWC) methods. The applied approach confirms to maintaining bus voltage within limits even against a very short transient time instant of solar radiation profile.
The studies on DG placement and capacity have been broadly reported in last few years. The unbalanced low voltage (LV) distribution network leads to an increase in losses and instability in the system. This paper investigates the voltage distribution profile in the IEEE-37 bus network, for which optimal placement and size of PV installation has been formulated to minimize the installation cost. The analysis performed on voltage magnitude distribution throughout the network, suggests that it remains sensitive to either active or reactive power injection according to the locations and prevailing solar radiation profile.
Although the topic is relevant and important, the manuscript lacks the originality, critical analysis, systematic literature review methodology, and technical depth expected for publication in an international journal. In its present form, it does no...