Richa Negi

Richa Negi


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
OYOmkar Yadav
Omkar Yadav
RNRicha Negi
Richa Negi
NKNand Kishor
Nand Kishor

5 January 2023 in Energies
Verified
Journal Article
Open access
PDF file
AYAnju Yadav
Anju Yadav
NKNand Kishor
Nand Kishor
RNRicha Negi
Richa Negi
This study mainly discusses the implications of solar radiation profiles and changes in load with respect to base load conditions on the PV placement, size, voltage violations, and curtailment cost of PV generation in the network. The PV installation is optimized using yearly solar radiation profiles, low, medium, and high, corresponding to three different locations. The network in the study is represented as a multiphase, with provision for the installation of both single- and three-phase PV systems. For the different load changes in either one of the phases or all three phases, the optimal placement and size of PV inverters are discussed. It is indicated that with load increase in all three phases, for low solar radiation profiles, the placement and size of PVs remain non-uniform, while for medium and high solar radiation, the distribution becomes comparatively uniform throughout the network. However, with a load increase in one of the phases, for low solar radiation, optimal placement compensates with three-phase PV installation, while for medium/high solar, the corresponding load increase phase contributes to greater PV installation. The voltage rise is observed at both load-connected and non-load-connected buses. Such buses in the network are those that form the common junction with the branches connected to another set of buses having optimally placed PVs. The voltage violations are experienced at the feeder end buses with single-phase PV installation, not only in the phase having a connected load but also in one of the other phases.

3 December 2018 in World Journal of Engineering
Verified
Journal Article
Closed access
Avadh PatiAvadh Pati
Avadh Pati
RNRicha Negi
Richa Negi
Purpose: The stability and input voltage saturation is a common problem associated with an active magnetic bearing (AMB) system. The purpose of this paper is to design a control scheme that stabilizes the single degree of freedom AMB system and also tackle the problem of input voltage saturation in the AMB system. Design/methodology/approach: The proposed control technique is a combination of two separate control schemes. First, the Backstepping control scheme is designed to stabilize and control the AMB system and then Chebyshev neural network (CNN)-based compensator is designed to tackle the input voltage saturation when the system control action is saturated. Findings: The mathematical and simulation results are presented to validate the effectiveness of proposed methodology for single-degree freedom AMB system. Originality/value: This paper introduces a CNN-based compensator with Backstepping control strategy to stabilize and tackle the problem of input voltage saturation in the 1-DOF AMB systems.

14 March 2012 in ISRN Computational Mathematics
Verified
Journal Article
Open access
PDF file
RNRicha Negi
Richa Negi
HKHaranath Kar
Haranath Kar
SPShubhi Purwar
Shubhi Purwar
This paper proposes a novel antiwindup controller for 2D discrete linear systems with saturating controls in Fornasini-Marchesini second local state space (FMSLSS) setting. A Lyapunov-based method to design an antiwindup gain of 2D discrete systems with saturating controls is established. Stability conditions allowing the design of antiwindup loops, in both local and global contexts have been derived. Numerical examples are provided to illustrate the applicability of the proposed method.

1 January 2019 in Mathematical Problems in Engineering
Verified
Journal Article
Open access
PDF file
VPVipin Chandra Pal
Vipin Chandra Pal
RNRicha Negi
Richa Negi
Quanxin ZhuQuanxin Zhu
Quanxin Zhu
This paper examines the stability analysis of discrete‐time control systems particularly during the event of actuator saturation and time‐varying state delay. With the help of Wirtinger inequality along with Lyapunov‐Krasovskii functional gain of state feedback controller is determined for stabilization of above system. The saturation nonlinearity is represented in the terms of convex hull. A new linear matrix inequality (LMI) criterion is settled with reciprocally convex combination based inequality which is dependent on delay. The proposed criterion is less conservative in concern to increase the delay bound and a controller is also simulated for real time problem of missile control system in this paper. It is also attained that projected stability criterion is less conservative compared to other outcomes. Furthermore, an optimization procedure together with LMI constraints has been proposed to maximize the attraction of domain.

12 March 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KRKIRAN RANA
KIRAN RANA
NKNand Kishor
Nand Kishor
RNRicha Negi
Richa Negi
MBMonalisa Biswal
Monalisa Biswal
High-voltage direct current (HVDC) transmission is preferred over high-voltage alternating current (HVAC) for long power lines for asynchronous power grid interconnection and high-level renewable energy integration. The control and protection functions associated with HVDC systems help with fast and secure clearance of faults. The control and protection challenges in the embedded HVDC network are of great concern for the stable and secure operation of an HVDC network. The DC fault current may reach an extremely high level in a rather short period because of the low impedance in a DC system, which is dangerous for converters, and disturbances in the AC network directly influence the performance of the HVDC system. Sometimes, faults on the AC side may lead to disconnection or failure of the DC link, causing reliability problems as well as huge economic losses. AC and DC protection solutions are being developed for HVDC systems to enhance their sustainability and reliability. As such, AC and DC faults should be detected and cleared at a faster rate. Therefore, in this article, the feasibility of the synchro-squeezed transform (SST) is analyzed for detection purposes. For more accurate and faster detection, the signal is first decomposed using the empirical mode decomposition (EMD) technique, and then the SST is applied. A discrete Teager energy (DTE) spectrum is obtained with the processed signal, which works as the detection index. The algorithm shows low sampling frequency requirements, with higher efficiency and reliability for the purpose. PSCAD/EMTDC version 4.6 software and MATLAB 2022a software is used for the modeling and simulation.