Garth Williams

Dr. Garth Williams


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 April 2017 in IUCrJ
Verified
Journal Article
Open access
BDBenedikt J. Daurer
Benedikt J. Daurer
KOKenta Okamoto
Kenta Okamoto
JBJohan Bielecki
Johan Bielecki
FMFilipe R. N. C. Maia
Filipe R. N. C. Maia
KMKerstin Mühlig
Kerstin Mühlig
DLDaniel S. D. Larsson
Daniel S. D. Larsson
This study explores the capabilities of the Coherent X-ray Imaging Instrument at the Linac Coherent Light Source to image small biological samples. The weak signal from small samples puts a significant demand on the experiment. AerosolizedOmono River virusparticles of ∼40 nm in diameter were injected into the submicrometre X-ray focus at a reduced pressure. Diffraction patterns were recorded on two area detectors. The statistical nature of the measurements from many individual particles provided information about the intensity profile of the X-ray beam, phase variations in the wavefront and the size distribution of the injected particles. The results point to a wider than expected size distribution (from ∼35 to ∼300 nm in diameter). This is likely to be owing to nonvolatile contaminants from larger droplets during aerosolization and droplet evaporation. The results suggest that the concentration of nonvolatile contaminants and the ratio between the volumes of the initial droplet and the sample particles is critical in such studies. The maximum beam intensity in the focus was found to be 1.9 × 1012photons per µm2per pulse. The full-width of the focus at half-maximum was estimated to be 500 nm (assuming 20% beamline transmission), and this width is larger than expected. Under these conditions, the diffraction signal from a sample-sized particle remained above the average background to a resolution of 4.25 nm. The results suggest that reducing the size of the initial droplets during aerosolization is necessary to bring small particles into the scope of detailed structural studies with X-ray lasers.

8 January 2021 in Physical Review B
Verified
Journal Article
Closed access
PDF file
YGYuan Gao
Yuan Gao
XHXiaojing Huang
Xiaojing Huang
HYHanfei Yan
Hanfei Yan
GWGarth Williams
Garth Williams
Bragg coherent diffractive imaging (BCDI) is a noninvasive microscopy technique that can visualize the morphology and internal lattice deviations of crystals with nanoscale spatial resolution and picometer deformation sensitivity. While BCDI has been successfully applied in various studies of materials, it is less successful for highly strained crystals. Specifically, it is difficult to correctly reconstruct the electron density of a highly strained object using conventional phase retrieval algorithms. Although various algorithms have been developed to overcome this challenge, most of them require a priori knowledge that is not always available in practice. Here we report a phase retrieval workflow that can invert diffraction patterns from multiple Bragg peaks simultaneously. The workflow is explored via simulated diffraction from crystals with various strain conditions. Reconstructions from the workflow consistently demonstrate more accurate electron density maps, in comparison with the conventional method. For highly strained crystals, the workflow improves the reliability and consistency of BCDI phase retrieval significantly.

28 September 2017 in Journal of Applied Crystallography
Verified
Journal Article
Open access
PDF file
RDRuben A. Dilanian
Ruben A. Dilanian
VSVictor Streltsov
Victor Streltsov
HCHannah D. Coughlan
Hannah D. Coughlan
HQHarry M. Quiney
Harry M. Quiney
Andrew V. MartinAndrew V. Martin
Andrew V. Martin
BABrian Abbey
Brian Abbey
The recent availability of extremely intense, femtosecond X-ray free-electron laser (XFEL) sources has spurred the development of serial femtosecond nanocrystallography (SFX). Here, SFX is used to analyze nanoscale crystals of β-hematin, the synthetic form of hemozoin which is a waste by-product of the malaria parasite. This analysis reveals significant differences in β-hematin data collected during SFX and synchrotron crystallography experiments. To interpret these differences two possibilities are considered: structural differences between the nanocrystal and larger crystalline forms of β-hematin, and radiation damage. Simulation studies show that structural inhomogeneity appears at present to provide a better fit to the experimental data. If confirmed, these observations will have implications for designing compounds that inhibit hemozoin formation and suggest that, for some systems at least, additional information may be gained by comparing structures obtained from nanocrystals and macroscopic crystals of the same molecule.

22 October 2019 in Journal of Synchrotron Radiation
Verified
Journal Article
Closed access
PDF file
ASAakriti Sharma
Aakriti Sharma
AMAmanda Muyskens
Amanda Muyskens
JGJoseph Guinness
Joseph Guinness
MPMatthew Polizzotto
Matthew Polizzotto
MFMontserrat Fuentes
Montserrat Fuentes
DHDean Hesterberg
Dean Hesterberg

1 January 2018 in IUCrJ
Verified
Journal Article
Open access
PDF file
CCCecilia M. Casadei
Cecilia M. Casadei
CTChing-Ju Tsai
Ching-Ju Tsai
ABAnton Barty
Anton Barty
MHMark S. Hunter
Mark S. Hunter
NZNadia A. Zatsepin
Nadia A. Zatsepin
MFMatthias Frank
Matthias Frank
Previous proof-of-concept measurements on single-layer two-dimensional membrane-protein crystals performed at X-ray free-electron lasers (FELs) have demonstrated that the collection of meaningful diffraction patterns, which is not possible at synchrotrons because of radiation-damage issues, is feasible. Here, the results obtained from the analysis of a thousand single-shot, room-temperature X-ray FEL diffraction images from two-dimensional crystals of a bacteriorhodopsin mutant are reported in detail. The high redundancy in the measurements boosts the intensity signal-to-noise ratio, so that the values of the diffracted intensities can be reliably determined down to the detector-edge resolution of 4 Å. The results show that two-dimensional serial crystallography at X-ray FELs is a suitable method to study membrane proteins to near-atomic length scales at ambient temperature. The method presented here can be extended to pump–probe studies of optically triggered structural changes on submillisecond timescales in two-dimensional crystals, which allow functionally relevant large-scale motions that may be quenched in three-dimensional crystals.

30 November 2022 in Physical Review B
Verified
Journal Article
Closed access
PDF file
YGYuan Gao
Yuan Gao
XHXiaojing Huang
Xiaojing Huang
RHRoss Harder
Ross Harder
WCWonsuk Cha
Wonsuk Cha
GWGarth Williams
Garth Williams
HYHanfei Yan
Hanfei Yan
Bragg coherent diffractive imaging (BCDI) is a noninvasive microscopy technique that can visualize the shape and internal lattice deviations of crystals with nanoscale spatial resolution and picometer deformation sensitivity. Its strain imaging capability relies on Fourier transform–based iterative phase retrieval algorithms, which are mostly developed under the kinematical approximation. Such approximation prohibits the application of BCDI on larger crystals, which are commonly seen in most emerging functional materials. Understanding the dynamical effect in BCDI, as well as developing a validated method for modeling BCDI at the dynamical diffraction limit, is crucial for applying BCDI to hierarchical systems that contain micron-sized crystals and grains. Here we report a comparative study on the impact of dynamical diffraction effects by comparing the reconstruction results from two measurements of the same crystal. Forward simulation is implemented to show subtle changes of interference fringes in the diffraction pattern due to the dynamical diffraction, and is compared directly with the experimental data.