Bunyong Rungroungdouyboon

Dr. Bunyong Rungroungdouyboon

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
PKPatcharee Kooncumchoo
Patcharee Kooncumchoo
PNPhuwarin Namdaeng
Phuwarin Namdaeng
SHSomrudee Hanmanop
Somrudee Hanmanop
BRBunyong Rungroungdouyboon
Bunyong Rungroungdouyboon
KKKultida Klarod
Kultida Klarod
NLNongnuch - Luangpon
Nongnuch - Luangpon
Chronic stroke leads to the impairment of lower limb function and gait performance. After in-hospital rehabilitation, most individuals lack continuous gait training because of the limited number of physical therapists. This study aimed to evaluate the effects of a newly invented gait training machine (I-Walk) on lower limb function and gait performance in chronic stroke individuals. Thirty community-dwelling chronic stroke individuals were allocated to the I-Walk machine group (n = 15) or the overground gait training (control) group (n = 15). Both groups received 30 min of upper limb and hand movement and sit-to-stand training. After that, the I-Walk group received 30 min of I-Walk training, while the control followed a 30-minute overground training program. All the individuals were trained 3 days/week for 8 weeks. The primary outcome of the motor recovery of lower limb impairment was measured using the Fugl–Meyer Assessment (FMA). The secondary outcomes for gait performance were the 6-minute walk test (6 MWT), the 10-meter walk test (10 MWT), and the Timed Up and Go (TUG). The two-way mixed-model ANOVA with the Bonferroni test was used to compare means within and between groups. The post-intervention motor and sensory subscales of the FMA significantly increased compared to the baseline in both groups. Moreover, the 6 MWT and 10 MWT values also improved in both groups. In addition, the mean difference of TUG in the I-Walk was higher than the control. The efficiency of I-Walk training was comparable to overground training and might be applied for chronic stroke gait training in the community.

1 January 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
Jinpitcha Mamom SathiyamasJinpitcha Mamom Sathiyamas
Jinpitcha Mamom Sathiyamas
BRBunyong Rungroungdouyboon
Bunyong Rungroungdouyboon
HDHanvedes Daovisan
Hanvedes Daovisan
CSChawakorn Sri-ngernyuang
Chawakorn Sri-ngernyuang
Monitoring the early stage of developing tissue injuries requires intact skin for surface detection of cell damage. However, electronic alert signal for early detection is limited due to the lack of accurate pressure sensors for lightly pigmented skin injuries in patients. We developed an innovative pressure sensor mattress that produces an electronic alert signal for the early detection of tissue injuries. The electronic alert signal is developed using a web and mobile application for pressure sensor mattress reporting. The mattress is based on body distributions with reference points, temperature, and a humidity sensor to detect lightly pigmented skin injuries. Early detection of the pressure sensor is linked to an electronic alert signal at 32 mm Hg, a temperature of 37 °C, a relative humidity of 33.5%, a response time of 10 s, a loading time of 30 g, a density area of 1 mA, and a resistance of 7.05 MPa (54 N) at 0.87 m3/min. The development of the innovative pressure sensor mattress using an electronic alert signal is in line with its enhanced pressure detection, temperature, and humidity sensors.

31 May 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
Jinpitcha Mamom SathiyamasJinpitcha Mamom Sathiyamas
Jinpitcha Mamom Sathiyamas
PRPhadungsak Rattanadecho
Phadungsak Rattanadecho
CMChatchai Mingmalairak
Chatchai Mingmalairak
BRBunyong Rungroungdouyboon
Bunyong Rungroungdouyboon
Designing new medical devices with advanced humidity sensors is of great significance for patients with incontinence-associated dermatitis (IAD). The primary goal of this study is to test the humidity-sensing mattress system for patients with IAD in clinical settings. The design of the mattress is set at 203 cm, with 10 × 3 sensors, dimensions of 19 × 32 cm, and a weighted bearing of 200 kg. The main sensors consist of a humidity-sensing film, a thin-film electrode (6 × 0.1 mm), and a glass substrate (500 nm). The sensitivity of the test mattress system showed that the resistance-humidity sensor was at a temperature of 35 °C (V0 = 30 V, V0 = 350 mV), with slope at 1.13 V/fF, f = 1 MHz, 20–90% RH, and a response time of 20 s at 2 μm. In addition, the humidity sensor reached 90% RH, with a response time of less than 10 s, a magnitude of 107–104 Ω, 1 mol%, CrO1.5, and FO1.5, respectively. This design is not only a simple, low-cost medical sensing device, but also opens a new pathway for developing humidity-sensing mattresses in the field of flexible sensors, wearable medical diagnostic devices, and health detection.

1 January 2020 in Journal of Periodontal & Implant Science
Verified
Journal Article
Open access
PDF file
TSTeerapan Sosakul
Teerapan Sosakul
PTPongsatorn Tuchpramuk
Pongsatorn Tuchpramuk
WSWARAPORN SUVANNAPRUK
WARAPORN SUVANNAPRUK
ASAutcharaporn Srion
Autcharaporn Srion
BRBunyong Rungroungdouyboon
Bunyong Rungroungdouyboon
JSJintamai Suwanprateeb
Jintamai Suwanprateeb
Sosakul T, et al. J Periodontal Implant Sci. 2020 Apr;50(2):106-120. https://doi.org/10.5051/jpis.2020.50.2.106

7 September 2025 in Ergonomics in Design: The Quarterly of Human Factors Applications
Verified
Journal Article
Closed access
NPNithisate Petju
Nithisate Petju
SSSairag Sa-adprai
Sairag Sa-adprai
NCNaris Charoenporn
Naris Charoenporn
BRBunyong Rungroungdouyboon
Bunyong Rungroungdouyboon
Technological advancements have increased the risk of work-related musculoskeletal disorders (WMSDs). This study assessed a passive shoulder exoskeleton during screw driving and electrical cable locking tasks in 14 males. Exoskeleton use significantly reduced anterior deltoid, middle deltoid, and pectoralis major muscle activity (%MVC, p < .001), and lowered perceived exertion in the hand/wrist, upper arm, and shoulder (p ≤ .003). Productivity increased (p < .001) and task time decreased (p = .021) with the exoskeleton. These findings demonstrate that passive shoulder exoskeletons effectively reduce physical strain and improve efficiency, offering a practical solution for mitigating WMSDs in labor-intensive industries.

22 June 2025 in Life
Verified
Journal Article
Open access
PDF file
TWThanyaporn Wongwatcharanon
Thanyaporn Wongwatcharanon
PEPinailug Tantilipikorn Earde
Pinailug Tantilipikorn Earde
BRBunyong Rungroungdouyboon
Bunyong Rungroungdouyboon
PKPatcharee Kooncumchoo
Patcharee Kooncumchoo
Upper-limb impairments after stroke significantly affect patients’ quality of life and require effective rehabilitation strategies. Rehabilitation devices play a vital role in enhancing motor recovery. This study evaluated the efficacy of the Arm Booster, a bilateral arm-training device, in improving upper-limb impairment in patients with chronic stroke. Eighteen participants were randomly assigned to two groups: a device group (n = 9), using the Arm Booster; and a conventional physiotherapy group (n = 9). Both groups performed six bilateral upper-limb exercises (32 repetitions each) three times per week for eight weeks. Participants were further classified into mild spasticity (n = 5) and moderate-to-severe spasticity (n = 4) subgroups. The primary outcome was motor impairment, assessed using the Fugl-Meyer Assessment of the Upper Extremity (FMA-UE). Secondary outcomes included spasticity, measured by the Modified Ashworth Scale (MAS), and daily functional use of the arm, assessed with the Motor Activity Log (MAL). Both groups showed significant improvements in FMA-UE scores and overall arm movement. The conventional group demonstrated additional gains in hand and wrist function and coordination. Notably, in the moderate-to-severe spasticity subgroup, the device group exhibited improvements in upper-limb movement and a trend toward reduced spasticity. These findings suggest that the Arm Booster may support motor recovery, encourage the use of the affected arm, improve movement control, and provide an efficient means for patients to exercise more frequently on their own.