Mohammad Saber Hashemi

Mr. Mohammad Saber Hashemi

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 April 2022 in Advanced Theory and Simulations
Verified
Journal Article
Open access
AMAaron McCrary
Aaron McCrary
MHMohammad Saber Hashemi
Mohammad Saber Hashemi
ASAzadeh Sheidaei
Azadeh Sheidaei
Energy‐dissipating mechanical metamaterials possess broad applications where absorbing shocks and isolating vibrations within monolithic and sandwich composite structures are required. This study presents the design of a novel bidirectional mechanical metamaterial with tunable stiffness and energy dissipation. By leveraging the phenomenon of Coulomb friction, the metamaterial dissipates energy when a small gap closes and two walls slide across one another under planar loading. The conceptual design of the metamaterial is parameterized, so the material behavior can be tailored to a particular application. A computational framework is built, using finite element analysis and a multi‐objective genetic algorithm to maximize the volumetric energy dissipation such that the unit cell does not undergo plastic deformation. The finite element mesh used in this analysis is first parametrically optimized to minimize simulation time while remaining within a global error threshold. The optimal unit cell is arrayed into a bulk material, formed into a hollow cylinder, and simulated under a compression cycle for different metamaterial densities. A prototype of the hollow cylinder is 3D printed via fused deposition modeling and is tested. Both the simulated and experimental results demonstrate the repeatability of the energy‐dissipating property with a strong correlation.

20 September 2021 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
SRSeyed Masoud Rezaeijo
Seyed Masoud Rezaeijo
BHBijan Hashemi
Bijan Hashemi
BMBahram Mofid
Bahram Mofid
MBMohsen Bakhshandeh
Mohsen Bakhshandeh
AMArash Mahdavi
Arash Mahdavi
MHMohammad Saber Hashemi
Mohammad Saber Hashemi
Background: We aimed to assess the feasibility of a dose painting (DP) procedure, known as simultaneous integrated boost intensity modulated radiation Therapy (SIB-IMRT), for treating prostate cancer with dominant intraprostatic lesions (DILs) based on multi-parametric magnetic resonance (mpMR) images and hierarchical clustering with a machine learning technique.Methods: The mpMR images of 120 patients were used to create hierarchical clustering and draw a dendrogram. Three clusters were selected for performing agglomerative clustering. Then, the DIL acquired from the mpMR images of 20 patients were categorized into three groups to have them treated with a DP procedure being composed of three planning target volumes (PTVs) determined as PTV1, PTV2, and PTV3 in treatment plans. The DP procedure was carried out on the patients wherein a total dose of 80, 85 and 91 Gy were delivered to the PTV1, PTV2, and PTV3, respectively. Dosimetric and radiobiologic parameters [Tumor Control Probability (TCP) and Normal Tissue Complication Probability (NTCP)] of the DP procedure were compared with those of the conventional IMRT and Three-Dimensional Conformal Radiation Therapy (3DCRT) procedures carried out on another group of 20 patients. A post-treatment follow-up was also made four months after the radiotherapy procedures.Results: All the dosimetric variables and the NTCPs of the organs at risks (OARs) revealed no significant difference between the DP and IMRT procedures. Regarding the TCP of three investigated PTVs, significant differences were observed between the DP versus IMRT and also DP versus 3DCRT procedures. At post-treatment follow-up, the DIL volumes and apparent diffusion coefficient (ADC) values in the DP group differed significantly (p-value < 0.001) from those of the IMRT. However, the whole prostate ADC and prostate-specific antigen (PSA) indicated no significant difference (p-value > 0.05) between the DP versus IMRT.Conclusions: The results of this comprehensive clinical trial illustrated the feasibility of our DP procedure for treating prostate cancer based on mpMR images validated with acquired patients’ dosimetric and radiobiologic assessment and their follow-ups. This study confirms significant potential of the proposed DP procedure as a promising treatment planning to achieve effective dose escalation and treatment for prostate cancer.Trial registration: IRCT20181006041257N1; Iranian Registry of Clinical Trials, Registered: 23 October 2019,https://en.irct.ir/trial/34305.

10 December 2019 in Biomechanics and Modeling in Mechanobiology
Verified
Journal Article
Closed access
PDF file
MHMohammad Saber Hashemi
Mohammad Saber Hashemi
MBMajid Baniassadi
Majid Baniassadi
MBMostafa Baghani
Mostafa Baghani
DGDaniel George
Daniel George
YRYves Remond
Yves Remond
ASAzadeh Sheidaei
Azadeh Sheidaei

1 April 2021 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
MHMohammad Saber Hashemi
Mohammad Saber Hashemi
AMAaron McCrary
Aaron McCrary
KKKarl H. Kraus
Karl H. Kraus
ASAzadeh Sheidaei
Azadeh Sheidaei

27 January 2023 in Materials
Verified
Journal Article
Open access
PDF file
SMSeyed Mohammad Ali Seyed Mahmoud
Seyed Mohammad Ali Seyed Mahmoud
GFGhader Faraji
Ghader Faraji
MBMostafa Baghani
Mostafa Baghani
MHMohammad Saber Hashemi
Mohammad Saber Hashemi
ASAzadeh Sheidaei
Azadeh Sheidaei
MBMajid Baniassadi
Majid Baniassadi
A computational methodology based on supervised machine learning (ML) is described for characterizing and designing anisotropic refractory composite alloys with desired thermal conductivities (TCs). The structural design variables are parameters of our fast computational microstructure generator, which were linked to the physical properties. Based on the Sobol sequence, a sufficiently large dataset of artificial microstructures with a fixed volume fraction (VF) was created. The TCs were calculated using our previously developed fast Fourier transform (FFT) homogenization approach. The resulting dataset was used to train our optimal autoencoder, establishing the intricate links between the material’s structure and properties. Specifically, the trained ML model’s inverse design of tungsten-30% (VF) copper with desired TCs was investigated. According to our case studies, our computational model accurately predicts TCs based on two perpendicular cut-section images of the experimental microstructures. The approach can be expanded to the robust inverse design of other material systems based on the target TCs.

3 February 2026 in Journal of the American Heart Association
Verified
Journal Article
Open access
MHMohammad Saber Hashemi
Mohammad Saber Hashemi
PAPeter Abdelmaseeh
Peter Abdelmaseeh
ANAtif Nehvi
Atif Nehvi
GPGregg S. Pressman
Gregg S. Pressman
Arash KheradvarArash Kheradvar
Arash Kheradvar
Background: Mitral annular calcification (MAC) is common and associated with increased cardiovascular risk and, when severe, mitral stenosis (MS). MAC‐related MS differs anatomically and hemodynamically from rheumatic MS (RMS), challenging standard diagnostic methods. This study compares structural and flow characteristics, including kinetic energy losses, across MAC‐related MS, RMS, and normal mitral valves, and evaluates the applicability of conventional diagnostic metrics in MAC. Methods: Three‐dimensional transesophageal echocardiographic data sets from 70 patients (22 normal mitral valves, 26 RMS valves, 22 MAC valves) were used to obtain linear, area, and volumetric measurements for valve comparison. Representative valves from each group were converted into 3‐dimensional silicone models for in vitro testing in a heart flow simulator. Transmitral flow was assessed with particle image velocimetry, flow energetics were quantified, and coefficients of contraction were derived from geometric and effective orifice areas. Results: Compared with RMS, MAC‐related MS had smaller anteroposterior dimensions, reduced valve volume, and lower coefficients of contraction. MAC demonstrated the highest transmitral velocities and energy dissipation in vitro. Unlike the normal model, neither MAC nor RMS produced a consistent transmitral vortex ring. Despite having a larger geometric orifice, MAC MS produced a greater pressure drop than RMS, likely due to increased flow disruption and lower coefficients of contraction. Conclusions: MAC‐related MS represents a unique pathophysiological entity, characterized by distinct structural and hemodynamic features. These findings underscore the necessity for disease‐specific diagnostic frameworks and multimodality imaging strategies to inform clinical decision making and guide emerging therapeutic approaches.