Combined voltage and frequency control is a critical control problem of modern power system to avoid blackouts. This paper discusses the simultaneous voltage and frequency control for an interconnected multi-source multi-area power system having two areas of equal generating capacity, each containing thermal, diesel, and wind units. A centralized model predictive controller (MPC) scheme is suggested to minimize voltage and frequency fluctuations. For effective control, a normalized performance criterion has been considered, and recently appeared Harris hawks optimization (HHO) algorithm has been integrated for the optimal tuning of MPC weights for the first time. The effectiveness of the proposed MPC-HHO controller has been verified after comparing its transient response performance indices with that of various existing controllers available in the literature. Quantitatively, the proposed controller yields a minimum performance index value, i.e. 0.000741, and it has been observed that the proposed MPC-HHO controlled system has 79.28%, 68.89%, 77.19%, and 81.96% better settling time for frequency deviation in area 1 when compared with PIλDF-LSA, FOIDF-LSA, MFO-FOPID, and PID-FA controllers, respectively. Further, the stochasticity in wind power generation has been considered with the help of Monte Carlo simulation of Autoregressive Integrated Moving Average model (ARIMA) model for practical wind speed data from National Renewable Energy Laboratory. The stability of the proposed controller has been verified using eigenvalues and Bode plot analysis, where the MPC-HHO controlled system was having more gain and phase margin values as compared to the PID controlled system. Furthermore, the robustness of the approach has been successfully evaluated by considering the nonlinearities, and parameter sensitivity analysis has been conducted after varying the parameters of voltage and frequency control loops and reevaluating the transient performance of the controlled system. Besides this, a separate case study wherein the most recent concepts like Electric Vehicle (EV) integration with grid and Virtual Inertia (VI) have been applied in addition to the proposed controller to provide auxiliary control support in the system. It has been validated that EV-VI coordinated MPC-HHO controller provides quality transient response under different scenarios including reduced inertia and stochastic load variations.
29 October 2022 in Electric Power Systems Research
This paper discusses the modelling and control of a combined load frequency control (LFC) and automatic voltage regulator (AVR) system for a multi-area power system network with each generating area includes thermal, diesel, and solar thermal power plant. Superconducting magnetic energy storage is incorporated with the LFC loop to provide auxiliary control against instantaneous changes in active power demand. Model Predictive Controller (MPC) has been employed in this study to improve the performance of AVR and LFC loops, and controller weights are fine-tuned with the help of Harris Hawks Optimization (HHO) approach. The effectiveness of the proposed MPC-HHO algorithm has been examined by comparing its transient performance indices with that of conventional MPC, PID, FOPID, fuzzy PID, integral double derivative with derivative filter controller as well as Particle Swarm Optimization and Sine Cosine Algorithm based Model Predictive Controllers. The proposed MPC-HHO controller gives superior results than the above-mentioned controllers.
Automatic Voltage Regulator (AVR) plays an important role in keeping voltage stability in the power system network. Since the performance of AVR gets affected due to the presence of load inertia and field circuit dynamics, it is important to take it into account while designing a control strategy. In this paper, efforts have been made to design a Model Predictive Controller based robust control strategy for the AVR system which gives good transient response characteristics as well as robustness against the external disturbance and parameter variation. The Model Predictive Controller weights of the system have been fine-tuned with the help of Particle Swarm Optimization (PSO) algorithm for further improvement in vital performance indices.
Accurate parameter estimation is essential for optimizing the performance of solar photovoltaic (PV) models. Traditional methods, such as deterministic approaches, often face challenges due to the inherent nonlinearity of PV systems, resulting in high computational demands and difficulty in accurately extracting key parameters. These methods frequently rely on approximations for the objective functions, which may compromise accuracy. To address these limitations, a novel application of walrus optimization algorithm (WaOA) is introduced for precise parameter extraction in solar PV cell diode models. Inspired by the social and foraging behavior of walruses, WaOA improves performance by globally expanding the search space and incorporates the Newton-Raphson method to refine objective function accuracy. The algorithm is validated on single diode (SDM), double diode (DDM), and triple diode models (TDM), demonstrating superior performance compared to other optimization techniques such as artificial hummingbird optimization (AHO), brown bear optimization (BO), war strategy optimization (WSO), and other hybrid algorithms. The proposed design resulted in faster convergence (about 200 iterations) and significant RMSE improvements of minimum 22.2%, 42.8%, and 29.8% for SDM, DDM, and TDM respectively compared to mentioned optimization approaches. The proposed design is validated across all diode models under various irradiance conditions, confirming its robustness and adaptability.