Purpose: This paper aims to reliability analysis of axially loaded steel columns at elevated temperatures considering the probabilistic features of fire. Design/methodology/approach: The response function used in the reliability analysis is based on the non-linear FEM calculations. The stochastic variability of temperature is integrated with the procedure similar to the parameters of loading and material properties. Direct Monte Carlo simulations (MCSs) are implemented for probabilistic analysis. Computational costs are reduced by polynomial approximation of the response function of the column. Findings: A design method for practical applications in the common Eurocode format is proposed. The proposed method can be used to estimate the failure probability of a steel column in fire conditions. If standard reliability criteria are applied, the results of the steel column buckling capacity in the fire according to the proposed procedure deviate from the Eurocode results in certain parameter ranges. Originality/value: The proposed method for design calculations makes use of the advantages of MCS results, while the need for the tedious amount of calculations for the end user are avoided as the predefined factors are implemented in the procedure of Eurocode format. The proposed method allows better differentiation of the fire probability in the capacity assessment compared to the existing design methods.
The stability of axially loaded steel columns with compact rectangular hollow sections at elevated temperatures is studied in this paper. The current Eurocode model for checking the buckling resistance of columns in fire was developed on a similar basis to that for ambient conditions. Due to the effect of the complex non-linear behaviour of steel in fire, the standard design model is not always fully appropriate, and certain parameter ranges may give unsafe results. In this work, an analytical method to determine the buckling resistance of steel columns at elevated temperatures is proposed, accounting for variable non-linear stiffness properties which have significant effects on the flexural buckling resistance of steel columns in fire. A finite element model was developed, and an extensive numerical study was performed to explore the effects of different parameters on the behaviours of steel columns at elevated temperatures. The proposed method is validated by comparing the performance with the results of the numerical model. Its improved accuracy with respect to the current Eurocode method is verified. The advantage of the new technique is its computational efficiency, which is valuable in reliability evaluations or data-based design procedures demanding numerous calculation cycles. The potential of the method for probability-based analysis is supported by the format, which enables us to explicitly handle the uncertainties of essential parameters. The proposed framework is suitable for extension to incorporate different material models and section types.
Structural steel hollow section members are extensively utilized in civil engineering due to their excellent mechanical performance, favourable geometry for corrosion protection, and aesthetic appeal. Degradation in material properties of steel and thermal expansion at high temperatures must be regarded in designs for fire situations. The closed inner space of hollow sections presents challenges at elevated temperatures. The present study examines the effect of expanding air on the stress state in section walls of hermetically sealed circular and rectangular hollow sections. The effect of the gas pressure is calculated analytically and numerically. The pressure of the expanding air may substantially reduce the capacity of a tubular member. The influence on resistance depends on temperature, volume of the air in the tubular member, and geometry of the hollow section. The results of the study indicate that rectangular hollow sections with relatively large width-to-thickness ratios are more sensitive to internal pressure than circular hollow sections. The temperature range where the adverse effect of internal pressure occurs can include realistic critical temperatures in practical design and therefore deserve special attention to ensure the required safety.