Hardware security is not a new problem but is ever-growing in consumer and medical domains owing to hyperconnectivity. A physical unclonable function (PUF) offers a promising hardware security solution for cryptographic key generation, identification, and authentication. However, electrical PUFs using nanomaterials or two-dimensional (2D) transition metal dichalcogenides (TMDCs) often have limited entropy and parameter space sources, both of which increase the vulnerability to attacks and act as bottlenecks for practical applications. We report an electrical PUF with enhanced entropy as well as parameter space by incorporating 2D TMDC heteronanostructures into field-effect transistors (FETs). Lateral heteronanostructures of 2D molybdenum disulfide and tungsten disulfide serve as a potent entropy source. The variable feature of FETs is further leveraged to enhance the parameter space that provides multiple challenge-response pairs, which are essential for PUFs. This combination results in stably repeatable yet highly variable FET characteristics as alternative electrical PUFs. Comprehensive PUF performance analyses validate the bit uniformity, reproducibility, uniqueness, randomness, false rates, and encoding capacity. The 2D material heteronanostructure-driven electrical PUFs with strong FET-to-FET variability can potentially be augmented as an immediately deployable and scalable security solution for various hardware devices.
Gas sensors applied in real-time detection of toxic gas leakage, air pollution, and respiration patterns require a reliable test platform to evaluate their characteristics, such as sensitivity and detection limits. However, securing reliable characteristics of a gas sensor is difficult, owing to the structural difference between the gas sensor measurement platform and the difference in measurement methods. This study investigates the effect of measurement conditions and system configurations on the sensitivity of two-dimensional (2D) material-based gas sensors. Herein, we developed a testbed to evaluate the response characteristics of MoS2-based gas sensors under a NO2 gas flow, which allows variations in their system configurations. Additionally, we demonstrated that the distance between the gas inlet and the sensor and gas inlet orientation influences the sensor performance. As the distance to the 2D gas sensor surface decreased from 4 to 2 mm, the sensitivity of the sensor improved to 9.20%. Furthermore, when the gas inlet orientation was perpendicular to the gas sensor surface, the sensitivity of the sensor was the maximum (4.29%). To attain the optimum operating conditions of the MoS2-based gas sensor, the effects of measurement conditions, such as gas concentration and temperature, on the sensitivity of the gas sensor were investigated.