Magnetoencephalography (MEG) plays a pivotal role in the diagnosis of brain disorders. In this review, we have investigated potential MEG applications for analysing brain disorders. The signal-to-noise ratio (SNRMEG = 2.2 db, SNREEG < 1 db) and spatial resolution (SRMEG = 2–3 mm, SREEG = 7–10 mm) is higher for MEG than EEG, thus MEG potentially facilitates accurate monitoring of cortical activity. We found that the direct electrophysiological MEG signals reflected the physiological status of neurological disorders and play a vital role in disease diagnosis. Single-channel connectivity, as well as brain network analysis, using MEG data acquired during resting state and a given task has been used for the diagnosis of neurological disorders such as epilepsy, Alzheimer’s, Parkinsonism, autism, and schizophrenia. The workflow of MEG and its potential applications in the diagnosis of disease and therapeutic planning are also discussed. We forecast that computer-aided algorithms will play a prominent role in the diagnosis and prediction of neurological diseases in the future. The outcome of this narrative review will aid researchers to utilise MEG in diagnostics.
Functional Near-Infrared Spectroscopy (fNIRS) is a wearable optical spectroscopy system originally developed for continuous and non-invasive monitoring of brain function by measuring blood oxygen concentration. Recent advancements in brain–computer interfacing allow us to control the neuron function of the brain by combining it with fNIRS to regulate cognitive function. In this review manuscript, we provide information regarding current advancement in fNIRS and how it provides advantages in developing brain–computer interfacing to enable neuron function. We also briefly discuss about how we can use this technology for further applications.
Background: BCI and AI-driven image segmentation are revolutionizing precision neurosurgery by enhancing surgical accuracy, reducing human error, and improving patient outcomes. Methods: This systematic review explores the integration of AI techniques—particularly DL and CNNs—with neuroimaging modalities such as MRI, CT, EEG, and ECoG for automated brain mapping and tissue classification. Eligible clinical and computational studies, primarily published between 2015 and 2025, were identified via PubMed, Scopus, and IEEE Xplore. The review follows PRISMA guidelines and is registered with the OSF (registration number: J59CY). Results: AI-based segmentation methods have demonstrated Dice similarity coefficients exceeding 0.91 in glioma boundary delineation and tumor segmentation tasks. Concurrently, BCI systems leveraging EEG and SSVEP paradigms have achieved information transfer rates surpassing 22.5 bits/min, enabling high-speed neural decoding with sub-second latency. We critically evaluate real-time neural signal processing pipelines and AI-guided surgical robotics, emphasizing clinical performance and architectural constraints. Integrated systems improve targeting precision and postoperative recovery across select neurosurgical applications. Conclusions: This review consolidates recent advancements in BCI and AI-driven medical imaging, identifies barriers to clinical adoption—including signal reliability, latency bottlenecks, and ethical uncertainties—and outlines research pathways essential for realizing closed-loop, intelligent neurosurgical platforms.
There have been multiple technological advancements that promise to gradually enable devices to measure and record signals with high resolution and accuracy in the domain of brain–computer interfaces (BCIs). Multimodal BCIs have been able to gain significant traction given their potential to enhance signal processing by integrating different recording modalities. In this review, we explore the integration of multiple neuroimaging and neurophysiological modalities, including electroencephalography (EEG), magnetoencephalography (MEG), functional magnetic resonance imaging (fMRI), electrocorticography (ECoG), and single-unit activity (SUA). This multimodal approach leverages the high temporal resolution of EEG and MEG with the spatial precision of fMRI, the invasive yet precise nature of ECoG, and the single-neuron specificity provided by SUA. The paper highlights the advantages of integrating multiple modalities, such as increased accuracy and reliability, and discusses the challenges and limitations of multimodal integration. Furthermore, we explain the data acquisition approaches for each of these modalities. We also demonstrate various software programs that help in extracting, cleaning, and refining the data. We conclude this paper with a discussion on the available literature, highlighting recent advances, challenges, and future directions for each of these modalities.
BCI biosensors enable continuous monitoring of neural activity, but existing systems face challenges in scalability, latency, and reliable integration with cloud infrastructure. This work presents a cloud-aware, real-time cognitive grid architecture for multimodal BCI biosensors, validated at the system level through a full physical prototype. The system integrates the BioAmp EXG Pill for signal acquisition with an RP2040 microcontroller for local preprocessing using edge-resident TinyML deployment for on-device feature/inference feasibility coupled with environmental context sensors to augment signal context for downstream analytics talking to the external world via Wi-Fi/4G connectivity. A tiered data pipeline was implemented: SD card buffering for raw signals, Redis for near-real-time streaming, PostgreSQL for structured analytics, and AWS S3 with Glacier for long-term archival. End-to-end validation demonstrated consistent edge-level inference with bounded latency, while cloud-assisted telemetry and analytics exhibited variable transmission and processing delays consistent with cellular connectivity and serverless execution characteristics; packet loss remained below 5%. Visualization was achieved through Python 3.10 using Matplotlib GUI, Grafana 10.2.3 dashboards, and on-device LCD displays. Hybrid deployment strategies—local development, simulated cloud testing, and limited cloud usage for benchmark capture—enabled cost-efficient validation while preserving architectural fidelity and latency observability. The results establish a scalable, modular, and energy-efficient biosensor framework, providing a foundation for advanced analytics and translational BCI applications to be explored in subsequent work, with explicit consideration of both edge-resident TinyML inference and cloud-based machine learning workflows.
There have been multiple technological advancements that promise to gradually enable devices to measure and record signals with high resolution and accuracy in the domain of Brain Computer Interfaces (BCI). Multi-modal BCIs have been able to gain significant traction given the potential to enhance signal processing by integrating different recording modalities. In this review, we explore the integration of multiple neuroimaging and neurophysiological modalities including Electroencephalography (EEG), Magnetoencephalography (MEG), Functional Magnetic Resonance Imaging (fMRI), Electrocorticography (ECoG), and Single-Unit Activity (SUA). This multimodal approach leverages the high temporal resolution of EEG and MEG with the spatial precision of fMRI, the invasive yet precise nature of ECoG, and the single-neuron specificity provided by SUA. The paper highlights the advantages of integrating multiple modalities, such as increased accuracy and reliability, and discusses the challenges and limitations of multimodal integration. Furthermore, we explain the data acquisition approaches for each of these modalities. We also demonstrate various software programs that help in extracting, cleaning, and refining the data. We conclude this paper with discussion on the available literature highlighting recent advances, challenges, and future directions for each of these modalities.