Shrikar R Desai

Prof. Dr. Shrikar R Desai


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 September 2023 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
ARAli Robaian
Ali Robaian
SDShrikar R Desai
Shrikar R Desai
JPJignesh R. Patel
Jignesh R. Patel
NANasser Alqhtani
Nasser Alqhtani
AAAbdullah Alqahtani
Abdullah Alqahtani
Mohmed Isaqali KarobariMohmed Isaqali Karobari
Mohmed Isaqali Karobari
Background: Dental implants emerge as a dependable and efficacious alternative for patients experiencing partial or complete tooth loss. The stability of these implants is influenced by surface topography and macro-level design. In cases where the height of the maxillary posterior region is diminished, employing short implants can prove advantageous. With the aim of examining the distribution of von Mises stress, strain, and micromovement in D4 bone quality surrounding platform-switched short implants, measuring 6 mm in length and featuring diameters ranging from 4 to 6 mm, as well as different thread designs, an in-depth finite element analysis was conducted under immediate loading conditions. Methodology: A 3D finite element model was constructed to simulate maxillary molar crowns, incorporating an implant with a length of 6 mm and varying diameters and thread designs. The diameters utilized were 4/3.6 mm, 5/4 mm, and 6/4.8 mm, while the thread designs included buttress, square, and triangle patterns. Each model underwent analysis with a 100 N force applied in two directions: vertical and oblique, relative to the long axis of the implant. Stress, strain, and micromovement in the peri-implant region were recorded, employing the Ansys Workbench R v.18.1 software for modelling and analysis. Results: When comparing all three diameters, the wide diameter (6 mm threads) exhibited the lowest values of peri-implant von Mises stresses (3.3 MPa and 35.1 MPa), strains (194 Ɛ and 484 Ɛ), and micromovements (0.7 μm and 1.3 Ɛ) subjected to axial and non-axial loading of a 100 N force. Notably, square microthreads yielded the most favorable stress parameters among the different thread shapes, manifesting the minimum values of stress, strains, and micromovements in their vicinity. Conclusion: For the treatment of atrophic ridges or in scenarios necessitating extensive surgical preparation of the implant site, a combination of short implants, wide diameters, and platform switching can be employed. In situations with reduced bone height and the requirement for an implant-supported prosthesis to replace a missing permanent maxillary molar, the utilization of wide-diameter platform-switched short implants measuring 6 mm in length, featuring a square thread design, should be taken into consideration.

1 January 2012 in Journal of Indian Society of Periodontology
Verified
Journal Article
Open access
PDF file
IKI Karthikeyan
I Karthikeyan
SDShrikar R Desai
Shrikar R Desai
RSRika Singh
Rika Singh
Background: Short implants are manufactured for use in atrophic regions of the jaws. Although many studies report on short implants as ≤10 mm length with considerable success, the literature regarding survival rate of ≤7 mm is sparse. Purpose: The purpose of this study was to systematically evaluate the publications concerning short dental implants defined as an implant with a length of ≤7 mm placed in the maxilla or in the mandible. Materials and Methods: A Medline and manual search was conducted to identify studies concerning short dental implants of length ≤7 mm published between 1991 and 2011. The articles included in this study report data on implant length ≤7 mm, such as demographic variables, implant type, location in jaws, observation time, prostheses and complications. Results: The 28 included studies represent one randomized controlled trial, 12 prospective studies and 10 retrospective studies. The survival rate of short implant was found to be increased from 80% to 90% gradually, with recent articles showing 100%. Conclusion: When severe atrophy of jaws was encountered, short and wide implants can be placed successfully.

1 January 2023 in Biomimetics
Verified
Journal Article
Open access
PDF file
SDShrikar R Desai
Shrikar R Desai
KKKiran Deepak Koulgikar
Kiran Deepak Koulgikar
NANasser Alqhtani
Nasser Alqhtani
ARAli Robaian
Ali Robaian
AAAbdullah Alqahtani
Abdullah Alqahtani
Mohammed MustafaMohammed Mustafa
Mohammed Mustafa
Titanium is the main component of dental implants. It is also routinely used as a framework material for implant-supported full-arch prostheses due to its low density, biocompatibility, and other mechanical properties. Remarkable mechanical properties such as lesser mass density and higher young’s modulus of graphene have gained popularity among scientists, improving the properties of biomedical implants. Thus, our study aimed to compare the outcome through the von Mises stresses generated on All-on-6 and All-on-3 implant models, as well as on the framework, and evaluate the effect of stress patterns on the crestal bone around implants in the mandible. FEA (Finite Element Analysis) study was carried out using edentulous mandible models. Four 3D FEA models with 3 and 6 implants were used (Model 1: Titanium bar-supported 6 straight implants; Model 2: Graphene bar-supported 6 straight implants; Model 3: Titanium bar-supported 3 implants with 30 degrees-tilted; Model 4: Graphene bar-supported 3 implants with 30 degrees-tilted) in order to simulate endosseous implant designs. The implant measuring 4.2 mm in diameter and 11.5 mm in length were used. The most distal implants in the 3-implant models were placed with angulation of 30 degrees; in 6 implants, they were vertically placed. All the models were analyzed for vertical and oblique axis with a single force magnitude of 100 N. In all four implant models and under loading conditions, the peak stress points were always on the neck of the most distal implant. von Mises stresses were within the normal stress range. In a conventional six-straight implant model supported by a titanium framework, the cortical stress in the region of implants was 25.27 MPa, whereas, in the graphene framework, it was 12.18 MPa. Under vertical load, there was a significant difference in the cortical stress around the tilted implants (30 degrees) in the 3-implant system of titanium and graphene frameworks, respectively, 70.31 MPa and 21.27 MPa. The graphene framework demonstrated better results than the titanium framework for the conventional six-implant system under vertical load, achieving stress of 30.09 MPa and 76.60 MPa, respectively. In the case of the 3-implant system, a significant difference in the bar stress was observed between graphene and titanium, respectively, 256.32 MPa and 180.1 MPa of bar stress. Within the limitation of this study, the peri-implant stresses were decreased using graphene framework models. Hence, it was possible to conclude that the best load-bearing capacity results were found in the graphene framework group compared to the titanium framework for All-on-6 and All-on-3 implant models, even though both materials are reliable options used as framework materials in implant-supported full-arch prostheses.

1 January 2014 in Journal of Indian Society of Periodontology
Verified
Journal Article
Open access
PDF file
RGReetika Gaddale
Reetika Gaddale
SDShrikar R Desai
Shrikar R Desai
JMJayashreeA Mudda
JayashreeA Mudda
IKI Karthikeyan
I Karthikeyan
Excessive gingival display is a frequent finding that can occur because of various intraoral or extraoral etiologies. This report describes the use of surgical lip repositioning technique for the management of a gummy smile associated with vertical maxillary excess and hypermobility of the upper lip. The procedure restricts the muscle pull of the elevator lip muscles by shortening the vestibule, thus reducing the gingival display when smiling. Healing was uneventful and follow-up examinations of 10 months revealed reduced gingival display. For patients desiring a less invasive alternative to orthognathic surgery, lip repositioning is a viable alternative.

1 January 2012 in Nigerian Journal of Clinical Practice
Verified
Journal Article
Closed access
PDF file
SDShrikar R Desai
Shrikar R Desai
DEDesai
Desai
GKG Katti
G Katti
IKI Karthikeyan
I Karthikeyan
Aim: Implants could be considered predictable tools for replacing missing teeth or teeth that are irrational to treat. Implant macrodesign includes thread, body shape and thread design. Implant threads should be designed to maximize the delivery of optimal favorable stresses. The aim of this finite element model study was to determine stresses and strains in bone by using various dental implant thread designs. Materials and Methods: A two-dimensional finite element model of an implant-bone system is developed by using Ansys. An oblique load of 100 N 45° to the vertical axis of implant as well as a vertical load was considered in the analyses. The study evaluated eight types of different thread designs to evaluate stresses and strains around the implants placed in D1 bone quality. Results: Forty-five-degree oblique von Mises stresses and strains were the highest for the filleted and rounded square thread with an angulation of 30° (216.70 MPa and 0.0165, respectively) and the lowest for the trapezoidal thread (144.39 MPa and 0.0015, respectively). Conclusions: The findings in this study suggest that the filleted and rounded square thread with an angulation of 30° showed highest stresses and strains at the implant-bone interface. The trapezoidal thread transmitted least amount of stresses and strains to the cortical bone than did other models.

6 October 2014 in Journal of Investigative and Clinical Dentistry
Verified
Journal Article
Closed access
PDF file
RGReetika Gaddale
Reetika Gaddale
JMJayashree A. Mudda
Jayashree A. Mudda
IKIlangovan Karthikeyan
Ilangovan Karthikeyan
SDShrikar R Desai
Shrikar R Desai
HSHarshada Shinde
Harshada Shinde
PDPavan Deshpande
Pavan Deshpande