Abdullah Alqahtani

Dr. Abdullah Alqahtani

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 September 2023 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
ARAli Robaian
Ali Robaian
SDShrikar R Desai
Shrikar R Desai
JPJignesh R. Patel
Jignesh R. Patel
NANasser Alqhtani
Nasser Alqhtani
AAAbdullah Alqahtani
Abdullah Alqahtani
Mohmed Isaqali KarobariMohmed Isaqali Karobari
Mohmed Isaqali Karobari
Background: Dental implants emerge as a dependable and efficacious alternative for patients experiencing partial or complete tooth loss. The stability of these implants is influenced by surface topography and macro-level design. In cases where the height of the maxillary posterior region is diminished, employing short implants can prove advantageous. With the aim of examining the distribution of von Mises stress, strain, and micromovement in D4 bone quality surrounding platform-switched short implants, measuring 6 mm in length and featuring diameters ranging from 4 to 6 mm, as well as different thread designs, an in-depth finite element analysis was conducted under immediate loading conditions. Methodology: A 3D finite element model was constructed to simulate maxillary molar crowns, incorporating an implant with a length of 6 mm and varying diameters and thread designs. The diameters utilized were 4/3.6 mm, 5/4 mm, and 6/4.8 mm, while the thread designs included buttress, square, and triangle patterns. Each model underwent analysis with a 100 N force applied in two directions: vertical and oblique, relative to the long axis of the implant. Stress, strain, and micromovement in the peri-implant region were recorded, employing the Ansys Workbench R v.18.1 software for modelling and analysis. Results: When comparing all three diameters, the wide diameter (6 mm threads) exhibited the lowest values of peri-implant von Mises stresses (3.3 MPa and 35.1 MPa), strains (194 Ɛ and 484 Ɛ), and micromovements (0.7 μm and 1.3 Ɛ) subjected to axial and non-axial loading of a 100 N force. Notably, square microthreads yielded the most favorable stress parameters among the different thread shapes, manifesting the minimum values of stress, strains, and micromovements in their vicinity. Conclusion: For the treatment of atrophic ridges or in scenarios necessitating extensive surgical preparation of the implant site, a combination of short implants, wide diameters, and platform switching can be employed. In situations with reduced bone height and the requirement for an implant-supported prosthesis to replace a missing permanent maxillary molar, the utilization of wide-diameter platform-switched short implants measuring 6 mm in length, featuring a square thread design, should be taken into consideration.

19 October 2022 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
AAAbdullah Alqahtani
Abdullah Alqahtani
NANasser Alqhtani
Nasser Alqhtani
KGKhalid Gufran
Khalid Gufran
IAIBRAHIM ALJULAYFI
IBRAHIM ALJULAYFI
AAAbdulaziz M. Alateek
Abdulaziz M. Alateek
YAYasser Khaled Alotaibi
Yasser Khaled Alotaibi
Dental professionals are playing an imperative role in the healthcare system. It is important to distribute the dental workforce across the country. Therefore, this study aimed at analyzing the recent distribution of the dental workforce in the Kingdom of Saudi Arabia (KSA) and determining the current dentist-to-population ratio in the KSA. This is a cross-sectional study focused on the dental workforces working in the KSA between 2015 and 2020. Complete data of dentists working in the KSA with different professional ranks were obtained. The data were stratified by gender, professional rank (Saudi and non-Saudi), area of working (13 provinces in the KSA), and sector of working (public and private). A complete list of all dental universities was obtained to identify the increasing number of dental institutes at this current moment. In addition, the dentist-to-population ratio was also evaluated based on the current inhabitant in the KSA and the total dental surgeons. There are a total of 27181 dental surgeons and 8022 dental auxiliaries registered in different specialties as of 2020. Saudi citizens are holding the majority of the posts in both dentist and dental auxiliary categories. The percentage of males and female is slightly higher in dentists and dental auxiliaries, respectively. It also indicated that where most of the dental personnel work in the private sector, dental auxiliaries work in the public sector. Moreover, the highest number of dental workforces is identified in the Riyadh region among all the 13 provinces. Based on the databases, the current dentist-to-population ratio is 1 : 1288.16. In conclusion, the number of dental professionals is ample; however, rural areas lack specialists. Saudi dentists are progressively replacing foreign dentists in different professional ranks working in the KSA.

1 January 2023 in Biomimetics
Verified
Journal Article
Open access
PDF file
SDShrikar R Desai
Shrikar R Desai
KKKiran Deepak Koulgikar
Kiran Deepak Koulgikar
NANasser Alqhtani
Nasser Alqhtani
ARAli Robaian
Ali Robaian
AAAbdullah Alqahtani
Abdullah Alqahtani
Mohammed MustafaMohammed Mustafa
Mohammed Mustafa
Titanium is the main component of dental implants. It is also routinely used as a framework material for implant-supported full-arch prostheses due to its low density, biocompatibility, and other mechanical properties. Remarkable mechanical properties such as lesser mass density and higher young’s modulus of graphene have gained popularity among scientists, improving the properties of biomedical implants. Thus, our study aimed to compare the outcome through the von Mises stresses generated on All-on-6 and All-on-3 implant models, as well as on the framework, and evaluate the effect of stress patterns on the crestal bone around implants in the mandible. FEA (Finite Element Analysis) study was carried out using edentulous mandible models. Four 3D FEA models with 3 and 6 implants were used (Model 1: Titanium bar-supported 6 straight implants; Model 2: Graphene bar-supported 6 straight implants; Model 3: Titanium bar-supported 3 implants with 30 degrees-tilted; Model 4: Graphene bar-supported 3 implants with 30 degrees-tilted) in order to simulate endosseous implant designs. The implant measuring 4.2 mm in diameter and 11.5 mm in length were used. The most distal implants in the 3-implant models were placed with angulation of 30 degrees; in 6 implants, they were vertically placed. All the models were analyzed for vertical and oblique axis with a single force magnitude of 100 N. In all four implant models and under loading conditions, the peak stress points were always on the neck of the most distal implant. von Mises stresses were within the normal stress range. In a conventional six-straight implant model supported by a titanium framework, the cortical stress in the region of implants was 25.27 MPa, whereas, in the graphene framework, it was 12.18 MPa. Under vertical load, there was a significant difference in the cortical stress around the tilted implants (30 degrees) in the 3-implant system of titanium and graphene frameworks, respectively, 70.31 MPa and 21.27 MPa. The graphene framework demonstrated better results than the titanium framework for the conventional six-implant system under vertical load, achieving stress of 30.09 MPa and 76.60 MPa, respectively. In the case of the 3-implant system, a significant difference in the bar stress was observed between graphene and titanium, respectively, 256.32 MPa and 180.1 MPa of bar stress. Within the limitation of this study, the peri-implant stresses were decreased using graphene framework models. Hence, it was possible to conclude that the best load-bearing capacity results were found in the graphene framework group compared to the titanium framework for All-on-6 and All-on-3 implant models, even though both materials are reliable options used as framework materials in implant-supported full-arch prostheses.

16 August 2025 in Plasmonics
Verified
Journal Article
Open access
PDF file
MZMahmud Uz Zaman
Mahmud Uz Zaman
AUarun uniyal
arun uniyal
NANasser Alqhtani
Nasser Alqhtani
GAGufranullah Ansari
Gufranullah Ansari
AAAbdullah Alqahtani
Abdullah Alqahtani
KAKhalid Ayidh Alqhatani
Khalid Ayidh Alqhatani
In order to detect dental diseases, the current numerical study proposes a novel multilayer surface plasmon resonance (SPR) sensor structure. Changes in the refractive index (RI) of the sensing medium (SM) can be detected by the proposed sensor. The proposed sensor has been implemented using copper (Cu), molybdenum ditelluride (MoTe2), and black phosphorus (BP) layers over the SF11 prism. Performance metrics such as sensitivity (S), detection accuracy (DA), figure of merit (FoM), and penetration depth (PD) are measured. Long-range RI of SM (1.33–1.631) yields the sensitivity of 106.4°/RIU with remarkable minimum reflectivity and a 3*BP layer. The maximum sensitivity of 110.27°/RIU is obtained by taking four times the BP layers. We also have an analysis of the cementum, dentin, and enamel layers of human teeth. In terms of sensitivity, DA, FoM, and PD, the suggested sensor shows encouraging results, paving the way for future advancements in plasmonic sensing technology. Moving forward, several key research avenues can be investigated to improve sensor performance and expand its applications.

3 April 2023 in Optical and Quantum Electronics
Verified
Journal Article
Closed access
PDF file
Mohammad Khursheed AlamMohammad Khursheed Alam
Mohammad Khursheed Alam
MZMahmud Uz Zaman
Mahmud Uz Zaman
NANasser Alqhtani
Nasser Alqhtani
ARAli Robaian
Ali Robaian
AAAbdullah Alqahtani
Abdullah Alqahtani
AAAli Alrahlah
Ali Alrahlah

25 July 2022 in Healthcare
Verified
Journal Article
Open access
PDF file
FAfaisal alali
faisal alali
BTbassel tarakji
bassel tarakji
AAAbdullah Alqahtani
Abdullah Alqahtani
NANasser Alqhtani
Nasser Alqhtani
ANAbdullah Bin nabhan
Abdullah Bin nabhan
MNMohammad Zakaria Nassani
Mohammad Zakaria Nassani
Background: It is essential for practicing dentists to have adequate knowledge of HIV/AIDS and its implications in the dental practice. Their attitudes should also be up to the professional expectations. This study aimed to assess knowledge of HIV/AIDS infection and attitudes towards its patients among dental students in Saudi Arabia. Methods: A questionnaire was prepared and distributed among a sample of dental students in Saudi Arabia. Twenty questions related to knowledge, attitudes, and oral manifestation of HIV were presented. Results: A total of 405 questionnaires were completed (67% response rate). Participants showed low knowledge of safety regarding HIV (39.5%) and 44.2% indicated that they would take an HIV test after needle stick injury. The proportion of correct answers regarding transmission of HIV through saliva, cardiopulmonary resuscitation, and aerosols by hand pieces was 41%, 37.5%, and 26.4%, respectively. Almost 50% of the surveyed dental students expressed unwillingness to treat HIV-positive patients. Poor knowledge was noted regarding oral manifestations of HIV (32.7%). Of the participants, 57.8% indicated that infection control procedures are very important for the treatment of HIV patients and 50.6% believed that a dentist can make a decision to reject the treatment of HIV patients. According to the participating dental students, the three major oral manifestations in HIV patients are hairy leukoplakia (47.4%), oral candidiasis (44.7%), and Kaposi’s sarcoma (43.5%). Conclusion: Inadequate knowledge and unprofessional attitude towards HIV/AIDS patients were identified among this group of dental students in Saudi Arabia. Dental educators and health care planners in Saudi Arabia should plan to promote the knowledge and attitudes of dental students in Saudi Arabia towards the treatment of HIV patients.