Tugce SEVIL YAMAN

Tugce SEVIL YAMAN


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2023 in Buildings
Verified
Journal Article
Open access
PDF file
TYTugce SEVIL YAMAN
Tugce SEVIL YAMAN
GLGregory Lucier
Gregory Lucier
An experimental program was implemented to investigate the shear transfer mechanism of carbon-fiber-reinforced polymer (CFRP) grids and expanded polystyrene (EPS) rigid foam insulation in three wythe precast concrete sandwich wall panels. The purpose of the research was to measure the shear flow capacity and to observe the failure mode(s) of precast concrete sandwich panels manufactured with a CFRP grid shear transfer mechanism between wythes. Six precast concrete sandwich panels were examined by push-out tests in which the center concrete wythe was pushed downward with respect to two outer concrete wythes. It was observed that the average shear flow capacity of the specimens having 2 in (51 mm) thick foam was higher than that of the specimens having 4 in (102 mm) thick foam. In addition, stiffness decreased significantly when the thickness of the EPS insulation increased. The failure mode for the panels included relative displacement between the center concrete wythe and the outer concrete wythes. Test results showed that panels tended to fail by CFRP grid rupture, CFRP grid pull-out, and loss of bond at the concrete/foam interface. Further tests should be performed to fully comprehend the nature of the shear transfer mechanism between the specific CFRP grid used and EPS rigid foam insulation.

31 October 2023 in Buildings
Verified
Journal Article
Open access
PDF file
TYTugce SEVIL YAMAN
Tugce SEVIL YAMAN
GLGregory Lucier
Gregory Lucier
Two precast concrete thin-shell wall panels were subjected to reverse-cyclic lateral loads to replicate wind fatigue over a 50-year design lifetime prior to loading to failure. The panels consisted of an outer wythe of concrete connected to light-gauge steel framing. Wire mesh was used to reinforce the concrete panel skin. Rivets provided a connection between the steel studs and the concrete panel. Two reinforced concrete (R/C) beams were integrated into the top and bottom parts of the panel, isolated from the concrete face by a thin sheet of extruded polystyrene (XPS) foam insulation. To connect these beams with the concrete face through the rigid foam insulation, a carbon-fiber-reinforced polymer (CFRP) grid was utilized. The aim of the experimental program was to characterize the behavior of the concrete and steel framing panel, with particular attention focused on the connections between the various structural elements of the panel. The first and second thin-shell panels survived the fatigue loading cycles and behaved elastically through failure-level lateral load cycles equivalent to 54 psf (2.6 kPa) and 66 psf (3.2 kPa) of applied uniform load, respectively. The failure mode was the separation of the top R/C beam from the concrete panel on the pull stroke of the loading cycle (when the connection between the beam and the concrete shell was in tension) for both specimens.

30 September 2022 in Journal of Structural Engineering & Applied Mechanics
Verified
Journal Article
Closed access
TYTugce SEVIL YAMAN
Tugce SEVIL YAMAN
Plate girders are designed to carry massive loads over large spans. Flanges resist moment and web resists shear forces. Shear strength of steel girders having slender webs is much less than the yielding shear capacity. It is mainly due to the buckling of the web prior to reaching the yield strength of the material. Webs are generally reinforced with transverse stiffeners to increase their buckling strength. Stiffened webs resist shear also after buckling, which is called as post buckling strength. Tension field theories explain the formation of the post buckling strength and predict the stiffened web’s ultimate shear strength. Most design code provisions are set on tension field theories. There exists plenty of tension field theories proposed until today. This paper covers the design shear strength check and design flexural strength check and the stiffeners’ design of a steel girder specimen which was designed intentionally to fail in shear buckling. Analysis and stiffeners’ design were performed according to the provisions for load and resistance factor design (LRFD) in the ANSI/American Institute of Steel Construction (AISC) 360-16 - Specification for Structural Steel Buildings.

15 September 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
UDUtku Doğan
Utku Doğan
TYTugce SEVIL YAMAN
Tugce SEVIL YAMAN
This paper examines reinforced concrete (R/C) chimney type structures that have been used intensively after industrialization. Within the scope of the study, the differences between the Turkish Building Earthquake Code 2018 (TBEC-2018) and the Turkish Building Earthquake Code 2007 (TBEC-2007) and the innovations brought by the TBEC-2018 were investigated. A waste hot gas chimney at the Mersin Soda Factory, af-filiated with Şişecam A.Ş., was analyzed using the linear Modal Response Spectrum Method in Integrated Software for Structural Analysis and Design (SAP2000) soft-ware, preserving the existing sectional dimensions. The results of the analysis per-formed in the past of the structure using the Modal Response Spectrum Method ac-cording to the TBEC-2007 were compared with the results obtained from this study. The differences between the two codes were addressed in terms of linear calculation methods. As a result of the research, the modal analysis method was compared with similar sections only within the scope of linear calculation methods. Even in this case, it was observed that the forces and moments calculated according to the 2018 earth-quake code increased significantly compared to the 2007 earthquake code values.

1 January 2026 in Advances in Civil Engineering
Verified
Journal Article
Open access
PDF file
UDUtku Doğan
Utku Doğan
TYTugce SEVIL YAMAN
Tugce SEVIL YAMAN
This study investigates the effects of the Turkish Building Earthquake Code 2018 (TBEC‐2018) on the seismic design of industrial chimney‐type reinforced concrete (RC) structures by comparing it with the previous regulation, Turkish Seismic Design Code 2007 (TSDC‐2007). A 130 m high RC chimney was analyzed using the linear modal response spectrum method in accordance with both codes. The comparison focuses on key seismic design parameters, including base shear forces, displacement demands, and internal force distributions. The results indicate that TBEC‐2018 leads to an increase in base shear forces of ~47%, while displacement values remain relatively unchanged. This behavior is attributed to differences in seismic hazard definitions and design spectra between the two codes. The findings highlight the implications of updated seismic provisions on the structural performance of tall industrial chimneys and provide insight into the design changes introduced by TBEC‐2018. The study contributes to the literature by offering a code‐based comparative evaluation specifically for chimney‐type structures, which are not extensively addressed in previous research.

13 July 2023 in Journal of Structural Engineering & Applied Mechanics
Verified
Journal Article
Closed access
IKİbrahim Emrah Katmer
İbrahim Emrah Katmer
TYTugce SEVIL YAMAN
Tugce SEVIL YAMAN