Gregory Lucier

Dr. Gregory Lucier

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2023 in Buildings
Verified
Journal Article
Open access
PDF file
TYTugce SEVIL YAMAN
Tugce SEVIL YAMAN
GLGregory Lucier
Gregory Lucier
An experimental program was implemented to investigate the shear transfer mechanism of carbon-fiber-reinforced polymer (CFRP) grids and expanded polystyrene (EPS) rigid foam insulation in three wythe precast concrete sandwich wall panels. The purpose of the research was to measure the shear flow capacity and to observe the failure mode(s) of precast concrete sandwich panels manufactured with a CFRP grid shear transfer mechanism between wythes. Six precast concrete sandwich panels were examined by push-out tests in which the center concrete wythe was pushed downward with respect to two outer concrete wythes. It was observed that the average shear flow capacity of the specimens having 2 in (51 mm) thick foam was higher than that of the specimens having 4 in (102 mm) thick foam. In addition, stiffness decreased significantly when the thickness of the EPS insulation increased. The failure mode for the panels included relative displacement between the center concrete wythe and the outer concrete wythes. Test results showed that panels tended to fail by CFRP grid rupture, CFRP grid pull-out, and loss of bond at the concrete/foam interface. Further tests should be performed to fully comprehend the nature of the shear transfer mechanism between the specific CFRP grid used and EPS rigid foam insulation.

1 August 2019 in Journal of Composites for Construction
Verified
Journal Article
Closed access
BMBrad C. McCoy
Brad C. McCoy
ZBZakariya Bourara
Zakariya Bourara
Rudolf SeracinoRudolf Seracino
Rudolf Seracino
GLGregory Lucier
Gregory Lucier
This paper examines the results of material testing of hybrid carbon and glass fiber-reinforced polymer (FRP) plates for use in prestressed mechanically fastened applications. The small-scale material tests were conducted in three phases: (1) uniaxial tension without holes, (2) uniaxial tension with open holes, and (3) uniaxial tension with single- and multibolt connections. In all three phases of testing, Digital Image Correlation (DIC) was used to obtain continuous strain data, showing holistic strain field development through failure. A total of 89 tests were conducted across 17 treatment groups to develop an anchor pattern and fastener spacing which is optimized with respect to maximum capacity and behavior under anticipated service load conditions. The tests presented comprise the initial phase of a larger project that aims to employ prestressed mechanically fastened FRP (MF-FRP) plates as a retrofit repair solution for deteriorated prestressed concrete bridge superstructures. Results conclude that 2 lines of 11 bolts with diameters of 12.7 mm, with longitudinal spacing of 100 mm and transverse spacing of 38 mm, provide an end-region anchor pattern with an ultimate capacity of 206 kN which is 89% of the ultimate capacity for the examined FRP plate with holes.

11 July 2018
Verified
Conference Paper
Closed access
BKBrent D. Keil
Brent D. Keil
FGFritz Gobler
Fritz Gobler
RMRichard D. Mielke
Richard D. Mielke
GLGregory Lucier
Gregory Lucier
GSGregory C. Sarvanis
Gregory C. Sarvanis
SKSpyros A. Karamanos
Spyros A. Karamanos
Welded lap joints are commonly used in large-diameter steel pipelines for water transmission. Their structural performance constitutes a key issue for safeguarding pipeline structural integrity with no loss of pressure containment, required even after a severe seismic event. Full-scale experiments are presented herein, and are part of an extensive project sponsored and coordinated by Northwest Pipe Co. on the structural performance of welded lap joints under severe ground-induced (seismic) actions. In the companion paper “Numerical Simulation of Steel Lap Welded Pipe Joint Behavior in Seismic Conditions” numerical simulation of the experiments are presented. The paper describes a series of large-scale experiments on welded lap joints in 25.75 in outside diameter steel pipes, with wall thickness of 0.135 in (3 specimens) or 0.250 in (3 specimens). The specimens were internally pressurized to 40% of yield pressure, and then subjected to four-point bending. Measurements of the bending load, characteristic displacements, and local strains at the joint area are reported. In all tests, the welded lap joints tested were capable of sustaining remarkable bending deformation, without any loss of pressure containment. This behavior supports the argument that welded lap joints, if appropriately constructed, can be used in seismic areas where severe and permanent ground-induced actions in the pipeline may occur.

1 May 2018 in Composite Structures
Verified
Journal Article
Closed access
PSPedram Sadeghian
Pedram Sadeghian
Rudolf SeracinoRudolf Seracino
Rudolf Seracino
BDBaishali Das
Baishali Das
GLGregory Lucier
Gregory Lucier

1 February 2025 in Journal of Bridge Engineering
Verified
Journal Article
Closed access
ASAnindya Samya Saha
Anindya Samya Saha
ETEric Throckmorton
Eric Throckmorton
GLGregory Lucier
Gregory Lucier
Rudolf SeracinoRudolf Seracino
Rudolf Seracino
GPGiorgio Proestos
Giorgio Proestos

1 February 2022 in Thin-Walled Structures
Verified
Journal Article
Closed access
BKBrent D. Keil
Brent D. Keil
DFDimitris Fappas
Dimitris Fappas
FGFritz Gobler
Fritz Gobler
GSGregory C. Sarvanis
Gregory C. Sarvanis
GCGiannoula Chatzopoulou
Giannoula Chatzopoulou
SKSpyros A. Karamanos
Spyros A. Karamanos