jammisetty yedukondalu

Mr. jammisetty yedukondalu


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 April 2024 in International Journal of Machine Learning and Cybernetics
Verified
Journal Article
Closed access
PDF file
PJPrince Jain
Prince Jain
JYjammisetty yedukondalu
jammisetty yedukondalu
HCHimanshu Chhabra
Himanshu Chhabra
UCUrvashi Chauhan
Urvashi Chauhan
LSLakhan Dev Sharma
Lakhan Dev Sharma

29 November 2023 in Arabian Journal for Science and Engineering
Verified
Journal Article
Closed access
PDF file
JYjammisetty yedukondalu
jammisetty yedukondalu
DSDiksha Sharma
Diksha Sharma
LSLakhan Dev Sharma
Lakhan Dev Sharma

21 January 2023 in Sensors
Verified
Journal Article
Open access
PDF file
JYjammisetty yedukondalu
jammisetty yedukondalu
LSLakhan Dev Sharma
Lakhan Dev Sharma
Background: Portable electroencephalogram (EEG) systems are often used in health care applications to record brain signals because their ease of use. An electrooculogram (EOG) is a common, low frequency, high amplitude artifact of the eye blink signal that might confuse disease diagnosis. As a result, artifact removal approaches in single EEG portable devices are in high demand. Materials: Dataset 2a from the BCI Competition IV was employed. It contains the EEG data from nine subjects. To determine the EOG effect, each session starts with 5 min of EEG data. This recording lasted for two minutes with the eyes open, one minute with the eyes closed, and one minute with eye movements. Methodology: This article presents the automated removal of EOG artifacts from EEG signals. Circulant Singular Spectrum Analysis (CiSSA) was used to decompose the EOG contaminated EEG signals into intrinsic mode functions (IMFs). Next, we identified the artifact signal components using kurtosis and energy values and removed them using 4-level discrete wavelet transform (DWT). Results: The proposed approach was evaluated on synthetic and real EEG data and found to be effective in eliminating EOG artifacts while maintaining low frequency EEG information. CiSSA-DWT achieved the best signal to artifact ratio (SAR), mean absolute error (MAE), relative root mean square error (RRMSE), and correlation coefficient (CC) of 1.4525, 0.0801, 18.274, and 0.9883, respectively. Comparison: The developed technique outperforms existing artifact suppression techniques according to performance measures. Conclusions: This advancement is important for brain science and can contribute as an initial pre-processing step for research related to EEG signals.

26 June 2024 in Arabian Journal for Science and Engineering
Verified
Journal Article
Closed access
PDF file
JYjammisetty yedukondalu
jammisetty yedukondalu
SKSahebgoud Karaddi
Sahebgoud Karaddi
HCHima Bindu CH
Hima Bindu CH
DSDiksha Sharma
Diksha Sharma
ASAchintya Kumar Sarkar
Achintya Kumar Sarkar
LSLakhan Dev Sharma
Lakhan Dev Sharma

6 October 2025 in IEEE Transactions on Consumer Electronics
Verified
Journal Article
Closed access
JYjammisetty yedukondalu
jammisetty yedukondalu
MRM. Ramesh
M. Ramesh
NJN. Janardhan
N. Janardhan
SKSahebgoud Karaddi
Sahebgoud Karaddi
TGT. Chandana Gowri
T. Chandana Gowri
SKSrinivasa Rao Karumuri
Srinivasa Rao Karumuri
The cognitive load triggers neural activity, which is crucial for understanding the brain’s response to mental stress or stimuli that induce stress. Electroencephalogram (EEG) signals were collected from a mental arithmetic task (MAT), simultaneous task EEG workload datasets and segmented into 4-second intervals. These segmented signals were then transformed into images using various time-frequency conversion methods (TF), including the Short-Time Fourier Transform (STFT), Continuous Wavelet Transform (CWT), Q Transform (QT), and Superlet Transform (SLT). The resulting TF images were fed into convolutional neural networks (CNNs), such as VGG19, ConvMixer, and a fusion of VGG19+ConvMixer. CNN models were trained using the Adam optimizer to detect cognitive load. The preprocessing involved normalization, and scaling in both phases. Among the models tested, the SLT-based TF-EEG with the fusion of the VGG19 and ConvMixer model outperformed other TF conversion methods and CNN architectures. The VGG19+ConvMixer utilizes the individual advantages of both VGG19 and ConvMixer models. It helps reduce overfitting and vanishing gradients, enhances performance with new data, improves GPU acceleration, and reduces computational cost due to its simpler architecture. However, the SLT effectively handles non-stationary data through its adaptive multi-resolution approach, making it ideal for EEG analysis. The SLT + VGG19 + ConvMixer model achieved accuracies of 97.26% on the MAT dataset and 96.04% on the STEW dataset, with all other evaluation metrics such as precision, sensitivity, specificity, F-score, MCC, Jaccard index, and Cohen’s kappa exceeding 94%. These findings can enhance real-time cognitive load monitoring, benefiting areas such as personalized learning, mental health, and stress management by detecting cognitive load to improve performance and reduce stress in critical situations.

9 June 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MCM. Krishna Chaitanya
M. Krishna Chaitanya
SKSivakrishna Kondaveeti
Sivakrishna Kondaveeti
JYjammisetty yedukondalu
jammisetty yedukondalu
MRMunipala Ramesh
Munipala Ramesh
VBV. Vijaya Sri Bolisetty
V. Vijaya Sri Bolisetty
SKSrinivasa Rao Karumuri
Srinivasa Rao Karumuri
Cardiac arrhythmia (CA) is a condition of the heart that raises the risk of heart failure, stroke, and mortality. A CA can be quickly detected by an lectrocardiogram (ECG), which analyses heart’s electrical activity. The primary diagnostic procedure, which is typically strenuous and ineffective, is the visual examination of ECG. In this article, a scaled bidirectional long short term memory (SB-LSTM) prototype is designed for the automatic categorization of CAs. The conventional Bidirectional long short term memory (BILSTM) is modified by embedding a scaling layer into it and hence it can able to categorize the CAs automatically and efficiently. After the various pre-processing steps, namely denoising, and normalization, the results show that there is an improvement in accuracy (ACCY). The newly developed prototype is endorsed by popular databases like MIT-BIH atrial fibrillation database (MITBIHAFDB), Creighton University Ventricular Tachyarrhythmia Database (CUVTDB), and MIT-BIH Malignant Ventricular Ectopy database (MITBIHVFDB) the physioNet warehouse, We succeeded in achieving an ACCY of 98.60%. Thus, the technique proposed presents a reliable and accurate procedure for the automatic categorization of CAs.