Chinmay Rao

Chinmay Rao

Radiology, Leiden University Medical Center, Leiden, The Netherlands
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 January 2023 in Sensors
Verified
Journal Article
Open access
PDF file
SPSuraj Pai
Suraj Pai
IHIbrahim Hadzic
Ibrahim Hadzic
CRChinmay Rao
Chinmay Rao
IZIvan Zhovannik
Ivan Zhovannik
ADAndré Dekker
André Dekker
Enrique HortalEnrique Hortal
Enrique Hortal
Research exploring CycleGAN-based synthetic image generation has recently accelerated in the medical community due to its ability to leverage unpaired images effectively. However, a commonly established drawback of the CycleGAN, the introduction of artifacts in generated images, makes it unreliable for medical imaging use cases. In an attempt to address this, we explore the effect of structure losses on the CycleGAN and propose a generalized frequency-based loss that aims at preserving the content in the frequency domain. We apply this loss to the use-case of cone-beam computed tomography (CBCT) translation to computed tomography (CT)-like quality. Synthetic CT (sCT) images generated from our methods are compared against baseline CycleGAN along with other existing structure losses proposed in the literature. Our methods (MAE: 85.5, MSE: 20433, NMSE: 0.026, PSNR: 30.02, SSIM: 0.935) quantitatively and qualitatively improve over the baseline CycleGAN (MAE: 88.8, MSE: 24244, NMSE: 0.03, PSNR: 29.37, SSIM: 0.935) across all investigated metrics and are more robust than existing methods. Furthermore, no observable artifacts or loss in image quality were observed. Finally, we demonstrated that sCTs generated using our methods have superior performance compared to the original CBCT images on selected downstream tasks.

13 January 2021
Verified
Book Chapter
Closed access
PDF file
CRChinmay Rao
Chinmay Rao
SPSuraj Pai
Suraj Pai
IHIbrahim Hadzic
Ibrahim Hadzic
IZIvan Zhovannik
Ivan Zhovannik
DBDennis Bontempi
Dennis Bontempi
ATAlberto Traverso
Alberto Traverso

1 August 2024 in Machine Learning for Biomedical Imaging
Verified
Journal Article
Open access
PDF file
PMPrerak Mody
Prerak Mody
NCNicolas F. Chaves-De-Plaza
Nicolas F. Chaves-De-Plaza
CRChinmay Rao
Chinmay Rao
EAEleftheria Astrenidou
Eleftheria Astrenidou
MRMischa de Ridder
Mischa de Ridder
MSMarius Staring
Marius Staring
Increased usage of automated tools like deep learning in medical image segmentation has alleviated the bottleneck of manual contouring. This has shifted manual labour to quality assessment (QA) of automated contours which involves detecting errors and correcting them. A potential solution to semi-automated QA is to use deep Bayesian uncertainty to recommend potentially erroneous regions, thus reducing time spent on error detection. Previous work has investigated the correspondence between uncertainty and error, however, no work has been done on improving the “utility” of Bayesian uncertainty maps such that it is only present in inaccurate regions and not in the accurate ones. Our work trains the FlipOut model with the Accuracy-vs-Uncertainty (AvU) loss which promotes uncertainty to be present only in inaccurate regions. We apply this method on datasets of two radiotherapy body sites, c.f. head-and-neck CT and prostate MR scans. Uncertainty heatmaps (i.e. predictive entropy) are evaluated against voxel inaccuracies using Receiver Operating Characteristic (ROC) and Precision-Recall (PR) curves. Numerical results show that when compared to the Bayesian baseline the proposed method successfully suppresses uncertainty for accurate voxels, with similar presence of uncertainty for inaccurate voxels. Code to reproduce experiments is available at https://github.com/prerakmody/bayesuncertainty-error-correspondence

22 May 2025 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
RGRuochen Gao
Ruochen Gao
PMPrerak Mody
Prerak Mody
CRChinmay Rao
Chinmay Rao
FDFrank Dankers
Frank Dankers
MSMarius Staring
Marius Staring
Objective. This study investigates key factors influencing deep learning-based dose prediction models for head and neck cancer radiation therapy. The goal is to evaluate model accuracy, robustness, and computational efficiency, and to identify key components necessary for optimal performance. Approach. We systematically analyze the impact of input and dose grid resolution, input type, loss function, model architecture, and noise on model performance. Two datasets are used: a public dataset (OpenKBP) and an in-house clinical dataset. Model performance is primarily evaluated using two metrics: dose score and dose–volume histogram (DVH) score. Main results. High-resolution inputs improve prediction accuracy (dose score and DVH score) by 8.6%–13.5% compared to low resolution. Using a combination of CT, planning target volumes, and organs-at-risk as input significantly enhances accuracy, with improvements of 57.4%–86.8% over using CT alone. Integrating mean absolute error (MAE) loss with value-based and criteria-based DVH loss functions further boosts DVH score by 7.2%–7.5% compared to MAE loss alone. In the robustness analysis, most models show minimal degradation under Poisson noise (0–0.3 Gy) but are more susceptible to adversarial noise (0.2–7.8 Gy). Notably, certain models, such as SwinUNETR, demonstrate superior robustness against adversarial perturbations. Significance. These findings highlight the importance of optimizing deep learning models and provide valuable guidance for achieving more accurate and reliable radiotherapy dose prediction.

15 September 2025 in arXiv
Verified
Preprint
Open access
PDF file
EIEfe Ilıcak
Efe Ilıcak
CRChinmay Rao
Chinmay Rao
CNChloe Najac
Chloe Najac
BLBeatrice Lena
Beatrice Lena
BIBaris Imre
Baris Imre
MSMarius Staring
Marius Staring
Magnetic resonance imaging (MRI) is the gold standard imaging modality for numerous diagnostic tasks, yet its usefulness is tempered due to its high cost and infrastructural requirements. Low-cost very-low-field portable scanners offer new opportunities, while enabling imaging outside conventional MRI suites. However, achieving diagnostic-quality images in clinically acceptable scan times remains challenging with these systems. Therefore methods for improving the image quality while reducing the scan duration are highly desirable. Here, we investigate a physics-informed 3D deep unrolled network for the reconstruction of portable MR acquisitions. Our approach includes a novel network architecture that utilizes momentum-based acceleration and leverages complex conjugate symmetry of k-space for improved reconstruction performance. Comprehensive evaluations on emulated datasets as well as 47mT portable MRI acquisitions demonstrate the improved reconstruction quality of the proposed method compared to existing methods.

4 November 2026 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
LBLaurens Beljaards
Laurens Beljaards
MOMatthias J. P. van Osch
Matthias J. P. van Osch
MNMartijn Nagtegaal
Martijn Nagtegaal
JKJochen Keupp
Jochen Keupp
CRChinmay Rao
Chinmay Rao
MSMarius Staring
Marius Staring
Purpose: Accurate and temporally high‐resolution estimation of subject motion is paramount for effective motion‐correction in MRI . This work proposes a novel approach for estimating subject motion within a 3D MRI scan with high temporal resolution. Methods: Starting from an incoherent sampling scheme, images are reconstructed from temporally ordered k‐space fractions via deep learning, enabling motion estimation via registration between each image. Assuming the bulk of the motion is removed using these initial estimates, the remaining misalignment between k‐space fractions is expected to be minimally correlated in time. Based on this insight, an iterative strategy is proposed in which shots are arbitrarily regrouped into new k‐space fractions, regardless of their original temporal ordering, for subsequent motion estimation and correction. This effectively increases the temporal resolution of the approach, enabling individual correction of all shots. Results: When applied to 3D T1w TFE MRI of the brain, the proposed approach “Deep‐Reorder” estimated a unique motion state for all shots, producing significantly better estimations of retrospective motion compared to estimation without iterative data regrouping. On prospectively motion‐corrupted scans with intentional head movement by volunteers, the proposed approach consistently improved image quality, producing less noisy images with reduced motion artifacts. Conclusion: In conclusion, the proposed approach, which is free of external tracking devices or navigators, effectively estimated 3D motion and corrected motion artifacts with increased temporal resolution.