Natural ventilation is an effective energy-saving strategy conducive to promoting sustainable agricultural production. A comprehensive numerical simulation is performed to predict the airflow pattern and thermal behavior in different arched greenhouses. The defined arc chord angle and position angle are employed to examine the natural ventilation process and corresponding roof vent scenarios. The numerical simulation is compared with the experimental data and good agreements are observed. Various configurations of ventilated structures, wind conditions and ventilation layouts are simulated on a high-resolution polyhedral grid based on a grid sensitivity analysis, which is beneficial to the optimization of greenhouse cooling combined with the water circulation heat collection system. The cooling effect in summer is analyzed by estimating the ventilation flow rate and microclimate inhomogeneity. The results demonstrate that the position angle of 85° of the arched greenhouses is an optimum ventilation direction and its impact on the microclimate is marginally affected by the change of the ventilation structure. The designed ventilation scheme has perfect air exchange capacity and cooling effect because the average air temperature can be reduced by 1.5°C more than the existing greenhouse in 10 minutes of ventilation. Likewise, the results show that the temperature and velocity inhomogeneities are approximately decreased by 33.3% and 11.89%, respectively. The practical value of the research is expected to provide basic quantitative conclusions for evaluating the natural ventilation performance.
Chinese solar greenhouses are unique facility agriculture buildings and widely used in northeastern China, providing a favorable requirement for crop growth. The north wall configurations play an essential role in heat storage and thermal insulation and directly affect the management of the internal environment. This research is devoted to further improve the thermal performance of the greenhouse and explore the potential of the north wall. A mathematical model was designed to investigate the concave-convex wall configurations based on computational fluid dynamics. Four passive heat-storage north walls were analyzed by using the same constituent materials, including a plane wall, a vertical wall, a horizontal wall and an alveolate wall. The numerical model was validated by experimental measurements. The temperature distributions of the north walls were examined and a comparative analysis of the heat storage-release capabilities was carried out. The results showed that the heat-storage capacity of the north wall is affected by the surface structure. Moreover, the critical factor influencing the air temperature is the sum of the heat load released by the wall and the energy increment of greenhouse air. The results suggested that the alveolate wall has preferable thermal accumulation capacity. The concave-convex wall configurations have a wider range of heat transfer performance along the thickness direction, while the plane wall has a superior thermal environment. This study provides a basic theoretical reference to rationally design the internal surface structures of the north wall.
Supplying homogenous and suitable airflow schemes were explored in Chinese solar greenhouses, which had a positive impact on the crop yield and quality. This paper provided a multifunctional fan–coil unit system (FCU) to assist in circulating air. This system could collect the surplus heat of daytime air and release it to heat the greenhouse at nighttime. However, the main problem to be faced was the nonuniform airflow distributions. Thus, this paper aimed to optimize and analyze the placement strategy of the FCU system for a Chinese solar greenhouse using the numerical methodology. The computational fluid dynamics model was constructed to evaluate the effect of the FCU system on the airflow field and to uphold its validation. The complex structure of the FCU system was simplified to a fan model by fitting the pressure jump and the air velocity to enhance the practicality of the simulation model. Finally, the coefficient of variation was used to optimize four parameters: the tilt angle, swing angle, height above the ground, and shape of the outlet baffle. The effective disturbance velocity percentage was proposed as the evaluation index to improve the turbulence characteristics. The mean absolute error (MAE) between the measured and simulated values of the air velocity for the two planes was 0.06 m/s and 0.09 m/s, and the root mean square error (RMSE) was 0.08 m/s and 0.11 m/s. The simulated results showed that the coefficient of variation before optimization was 0.76, and the effective disturbance velocity percentages of the planes at 0.7 m and 1.0 m from the ground were 42.73% and 41.02%, respectively. After optimization, the coefficient of variation was reduced to 0.33, and the effective disturbance velocity percentages of the two planes increased to 58.68% and 43.73%, respectively. These results significantly improved the uniformity of the interior airflow field. This paper provides a reference for the design and installation of the FCU system.